Transformer Turns Ratio
measures a transformer's number of primary winding turns to it's secondary turns.
See Also: Winding, Transformer Turns Ratio Testers
-
Product
Current Transformer Tester
CT-T1
-
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.
-
Product
1 Channel, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTA
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Fully Automatic Transformer Oil Test Set
OTS-A series
-
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
Product
Transformers (Murata Power Solutions Products)
-
Murata transformers are ideally suited to high-frequency designs. The products come in a variety of industry-standard packages and can be used in applications where impedance matching, voltage conversion, isolation and current sensing may be required.
-
Product
Turn Key Laser and LED Sources with Picosecond Pulse and Repetition Rate up to 100 MHz
DeltaDiode
-
DeltaDiodes utilize laser diode and LED technology to generate short optical pulses over a very wide range of repetition rates and wavelengths. Optical pulses as short as 50ps can be generated at repetition rates up to 100MHz.
-
Product
Quasi Square Wave Constant Voltage Transformers
-
Osborne Quasi Square Wave Constant Voltage Transformers are used to regulate output voltages for applications that have varying input voltages. When used with a rectifier conversion circuit, these units provide an elegant design approach to voltage regulation. Osborne achieves this innovative approach by partnering the constant voltage transformer with an auxiliary resonant capacitor winding. The result is a unique (though time honored) technology that offers reliability, performance, and cost advantages over other styles of voltage regulation.
-
Product
Stable Isotope Ratio Mass Spectrometer
isoprime precisION (IRMS)
-
Elementar Analysensysteme GmbH
Stable isotope analysis provides great insight into diverse applications and delivers a greater understanding of the micro and macro cycling mechanisms of the organic elements through the world around us. Though our collective knowledge continues to grow, so does our desire to explore further. The more we know, the more we question.
-
Product
Transformer Oil Gas Analysis
-
It is necessary to analyze outgas in transformer insulation oil in power plant facilities. Shimadzu offers a System GC compliant with ASTM D 3612 Method B (oil stripper sampling) or ASTM D 3612 Method C (headspace sampling). The Nexis GC-2030TOGAS3 system, equipped with a PDHID, enables the analysis of more trace amounts of permanent gas than conventional systems.
-
Product
Transformer Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
Product
Transformer Demagnetization Tester
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
Product
Solid State Synchro Control Transformer and Solid State Resolver Control Transformer
SCT-RCT Series
-
Computer Conversions Corporation
The SCT Series are low cost, miniature, solid state control transformers designed for military and industrial control applications. They will directly replace conventional electromechanical control transformers & thus provide digital control to existing analog servo systems. They simultaneously accept a 3 wire synchro input (0) and a digital angle input (0), and provide an ouput which is the sine of the difference between these two input angles (A sin wt sin (0-0) ("wt" is the synchro excitation frequency).
-
Product
20 Amp Current Transformer Burden Test Set
1044A
-
Due to overwhelming demand, TESCO is pleased to re-introduce the 1044A 20 Amp Current Transformer Burden Test Set. This light weight, hand held unit is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The 1044A provides utilities a less expensive and more traditional option for checking larger services for potential meter circuit related issues.
-
Product
Hand Held Microwave Moisture MeterFor Water/Cement Ratios of Fresh Concrete
Cementometer
-
The James Cementometer represents a break-through in modern moisture measurement technology. By utilizing the latest microwave and microprocessor science, the Cementometer can determine the moisture content of freshly mixed cement, concrete, and mortar. Simply insert the prongs of the probe into the material to be measured and instantaneously the water cement ratio is shown on the easy to read display.
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
Clamp-On / Precision / Split Core Current Transformer
-
Transformer Ratio (Arms) : 100A / 1AColours : Red, yellow, blueConnection : Safety Sockets for Banana Plugs ф 4mm Jaw Opening : Cable Dia 15mm max.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
High Voltage Transformer
-
RR manufactures HIGH VOLTAGE TRANSFORMERS for various Industrial Applications.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Standard Current Transformers
-
Measurements International Ltd.
Single Range, Highest Permeability, Wide Measurement Range, Negligible Current Errors, High Accuracy.
-
Product
Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm
OSA201C
-
Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.
-
Product
4ch, 1G to 30Gb/s Bit Error Ratio Tester (BERT) With Eye Checker
RB3004
-
*Low cost continuous 4ch, 1G to 30Gb/s Bit Error Ratio Tester (BERT) and Eye Checker
-
Product
Single Gas Transformer DGA
-
Hydran composite gas Dissolved Gas Analysis (DGA) products provide essential online monitoring of transformer oil. The Hydran line is the perfect cost-effective application for small- and medium-sized transformers where customers need to know about developing fault conditions that could cause unscheduled outages.The Hydran products allow for the addition of expansion to the base unit, allowing for greater measurement accuracy
-
Product
Potential Transformers
-
Osborne Potential Transformers (PT’s) are used to reduce higher system voltages to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when potential transformers are to be used for power measuring applications.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
VARIABLE TRANSFORMER DC POWER
208163V
-
Motorized Variable Transformer Controlled Power Supply, P/N 208163VInput power: 208 VAC, 6 Amps, 3 PH, 60 HzOutput: 0 to 120 VDC, 16 Amps max.Ripple: 5%Manual control with variable transformerCircuit breaker / ON OFF on the 208 VAC, 3 PH input lineProtection fuse provided on the outputPOWER ON lightIndoor enclosure: 24H x 20W x 9DVoltmeter and ammeter are installed to monitor the output.All input/output connections are available inside the enclosureSystem includes main unit and remote assembly.
-
Product
Transformer Tester
-
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
Product
Transformer Performance Tester
6691
-
applying ±90V voltage on the winding of the transformer demagnetized and get the voltage value on the terminal and the current value in the winding to draw the hysteresis characteristic curve. This method can be used for linear quantitative analysis of residual magnetism in transformers, and fast demagnetization can be achieved by tracking hysteresis curves. The analyzer can measure magnetism residual rate before and after demagnetization.
-
Product
Instrumentation Transformers
-
RR manufactures Transformer for Oil Test Set / Oil BDV Set. These are available in→ 25-0-25 KV→ 30-0-30 KV→ 40-0-40 KV→ 50-0-50 KV→ 60-0-60KV→ Higher ranges availableThese transformers are available in various models to suit various needs and budgets. We Specialize in manufacturing LOW WEIGHT TRANSFORMERS for AUTOMATIC OIL TEST SET MICROPROCESORS.
-
Product
Transformer Ratio Meters
-
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
Product
Turns Ratio Meter
Model TRM200
-
Turns Ratio Meter Model TRM200 is widely used in transformer industry in manufacturing and repairing service. It directly display the ratio of LT turns & HT turns. It is capable to measure turns ratio till 1:1200. Turns ratio meter is designed to be a rugged and reliable. It is equipped with stable 250mA source. The design is based upon in-house invented & patented technology. TRM200 has also option for 1amp current source on demand.