Transformer Turns Ratio
measures a transformer's number of primary winding turns to it's secondary turns.
See Also: Winding, Transformer Turns Ratio Testers
-
Product
Signal Transformers
-
Signal transformers are used as a step-up / step-down, isolating, or impedance matching component in electronic devices.
-
Product
High Current Transformers
-
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
Product
Turning Mirror on Universal Mount
10769B
-
The Keysight 10769B Turning Mirror on Universal Mount deflects a laser beam at any angle, in either the vertical or the horizontal polarization plane of the beam. The 10769B contains the same turning mirror as the 10769A, but has a different mounting.
-
Product
High Voltage Transformer
-
RR manufactures HIGH VOLTAGE TRANSFORMERS for various Industrial Applications.
-
Product
Solid State Synchro Control Transformer and Solid State Resolver Control Transformer
SCT-RCT Series
-
Computer Conversions Corporation
The SCT Series are low cost, miniature, solid state control transformers designed for military and industrial control applications. They will directly replace conventional electromechanical control transformers & thus provide digital control to existing analog servo systems. They simultaneously accept a 3 wire synchro input (0) and a digital angle input (0), and provide an ouput which is the sine of the difference between these two input angles (A sin wt sin (0-0) ("wt" is the synchro excitation frequency).
-
Product
Split Core Current Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
Product
Burn Down Transformer
ATG 2
-
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
Product
Isolation Transformers 230V
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
Product
Transformer Performance Tester
6691
-
applying ±90V voltage on the winding of the transformer demagnetized and get the voltage value on the terminal and the current value in the winding to draw the hysteresis characteristic curve. This method can be used for linear quantitative analysis of residual magnetism in transformers, and fast demagnetization can be achieved by tracking hysteresis curves. The analyzer can measure magnetism residual rate before and after demagnetization.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Flux Testing Transformer
-
The testing equipment is manufactured in strict adherence with industry standards using superior quality raw materials, sourced from reputed vendor in market.
-
Product
Control Transformers
-
ENTES control transformers ensure the safe operation of measuring devices with 24 VAC supply voltage for electical control panels. Input voltages of Control transformers are either fixed (230 or 400V) or selectable with taps (400;230+15-15).
-
Product
High Voltage Transformers
-
We, NMC, are engaged in manufacturing AC/DC High Voltage Transformers ranging from 5kv upto 150Kv having current capacity from 10mA to 200mA AC/DC in Air cooled or Oil Cooled type as per the customer requirement.
-
Product
AC/DC Clamp-On Current Transformers
-
AC/DC Clamp-On Current Transformers by AYA Instruments
-
Product
Current Transformer
ST-6RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 400~600
-
Product
Zero Phase Current Transformer
MZL-65
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
Product
1 Channel, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTA
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Instrument Transformer
CT & PT Test Equipment
-
Measurements International Ltd.
Calibration of Voltage and Current Transformers from a Single Instrument, Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard, Calibration of Voltage Transformers (VT) up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors, Calibration of Current Transformers (CT) Up to 10000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators, Test Frequency from 15 Hz to 100 Hz70.
-
Product
Split type AC Current Transformer
CTS-600
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*5A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy to install by metal fitting.
-
Product
Transformer Demagnetization Tester
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
Product
Variable Transformer DC Power Supplies
-
Variable DC power supplies are AC to DC power supplies with a variable DC output. The output can be varied with a Variable Transformer (also known as variac). The Variable Transformer can be adjusted manually or with a motorized control. The AC input power can be single phase or three phases. With single phase AC input, the DC output ripple is very high (50%). With three phase AC input, the DC output ripple is low (5%). This would be a key benefit for selecting three phase AC input instead of single phase.
-
Product
Distribution Transformer Tester
ADOC-3
-
The ADOC-3 is an equipment that has been designed to test distribution network transformers from 5 kVA to 3MVA.
-
Product
Transformer Testing Panel
VTTP
-
Capable to Test Up to 25 MVA (Other Ranges are Available On Request). Useful for No Load Test (O.C.), Load Test (S.C.), DVDF Test HV Test of Transformer. Mains indication by R,Y,B indication Lamp. Over voltage, over current protection.
-
Product
Precision Multirange Current Transformer
P-2000
-
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
Product
Bobbin Winding Coil Turn Tester
SS108 Series
-
This (SS108** series) winding coil turn testers are used for testing turn of various coils without core, like as: generator winding, transformer winding, relay, inductor, contactor, ignition coil, voice coil, etc.
-
Product
Transformer Rated And Self-Contained Training Bench
Model 8803A
-
The PowerMaster® 8803A Transformer Rated and Self-Contained Training Bench uses an integrated Windows-based touchscreen interface to select and modify a simulated error scenario while located at the bench. This display is mounted on an articulating arm to maximize bench space and enable line-of-sight while standing.
-
Product
10-channel turn-to-turn Insulation Scanner
TH28831
-
Changzhou Tonghui Electronic Co., Ltd.
Work together with TH2883, expand single channel to 10-channel
-
Product
Potential Transformer Test Set
-
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.





























