Winding Resistance
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
Microohmmeter
MMR-6700
-
The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.
-
Product
Winding Resistance Meter 100Amps, 3 Channels
WR100-13R
-
Raytech Digital Winding Resistance meter WR100-13R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Transformer Testing Instrument
-
The Motwane Manufacturing Company
Transformers are a vital link in the electrical distribution system. Accurate and timely transformer maintenance can prevent breakdowns by detecting potential causes, and eliminating them before danger strikes. In addition, regular maintenance ensures multiple years of trouble-free operation. Motwane offers a wide range of transformer maintenance products, such as the transformer turn ratio tester, winding resistance tester, automatic oil BDV tester, and oil tan delta resistivity tester.
-
Product
High-Current 4-Wire Winding Resistance Meter
TWO-1100S
-
Shenzhen Feso Automation Technology Co., Ltd.
High-current 4-wire winding resistance meter with DC test current up to 100 A — measures 30 µΩ–4 Ω with ±0.2 % reading accuracy for transformer and rotating-machine windings.
-
Product
DC Resistance Tester
GDZRS-20A
-
GDZRS series Winding DC resistance tester is optimal designed for measuring three phase winding DC resistance of big capacity transformer. It can test three phase winding DC resistances at the same time
-
Product
Winding Resistance Meter 100Amps, 2 Channels
WR100-12R
-
Raytech Digital Winding Resistance meter WR100-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Current Transformer Tester
CTT
-
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
Product
Transformer Winding Resistance Tester
KRI 9310
-
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
Product
Winding Resistance Meter
-
* Selectable four resistance ranges.* 4 1/2 digits LED display* High measurement Current (10A)* True four Technique elimanates lead resistance errors Systems* Fully protected against overloads* Proven design* Computer connectivity through RS 232
-
Product
Automatic Three Phase Transformer Ratio Meter
ATRM PLUS
-
*Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.
-
Product
Electrical Measurements Test
-
The tests are performed to measure and collect data from electrical and electronic parts using various measurement methods including, but not limited, to the following: capacitance, resistance, winding resistance, insulation resistance, magnetic permeability, power input, and quality factor Q.
-
Product
Current Transformer Testers
-
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
Product
Motor Winding Ohmmeter
RMO-M Series
-
The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement
-
Product
Winding Resistance Tester with Demagnetisation Circuit
WRT-10D
-
The WRT-10D is a high performance winding resistance tester designed for power transformer and large motor applications. It is equipped with a bright LCD display, a rugged high quality cable set, a built-in printer, a full QWERTY keypad and a demagnetisation circuit.
-
Product
Transformer Heat Run Tester
-
1. Suitable for all transformers below 240MVA heat run test and winding resistance testing.2. Printing heat run data automatically.3. With double power supply, can test high voltage side and low voltage side simultaneously and test any operation respectively.4. With anti breakage protection function of inductive test items.
-
Product
Motor/Generator Test Equipment
-
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.
-
Product
Winding Resistance Meter
TRM 25
-
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Product
Micro-Ohmmeters
-
Micro-Ohmmeter is an affordable 7 range, 4-Wire Kelvin based product that is used to test electrical resistance on a wide variety of applications including winding resistance, contact resistance, and component testing. The 720A micro-ohmmeter has an autorange feature (available with NSN package) and is compatible with an RS232C interface (OP-232). Thanks to its wide-range capabilities, ease of use, and CE mark, this micro-ohmmeter is used commonly across the globe.
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Product
AC Motor Tester
AIP892X series
-
Qingdao AIP Intelligent Instruments Co., Ltd
This product is suitable for electrical performance testing of all types of motors, such as home appliance motors (washing machines, air conditioners, fans, etc.), pump motors, stepper motors, etc. One-stop testing completes all set items, stable, fast, efficient and accurate, widely used by domestic and foreign enterprises.This AC motor tester test items: AC Hi-pot, insulation resistance, surge, DC winding resistance, no-load characteristics, low voltage start, locked rotor, rotation, PG characteristics.
-
Product
Winding Resistance Meter 50Amps, 2 Channels Rack
WR50-12R
-
Raytech Digital Winding Resistance meter WR50-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
-
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.
-
Product
Current Transformer Tester
HTCT-300
-
Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Winding Resistance Meter
TRM 104
-
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
Product
STDETransformer Demagnetizer
STDE
-
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.