Showing results: 1591 - 1605 of 9089 items found.
-
40-765-002 -
Pickering Interfaces Ltd.
This terminated dual 16 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
PX32101 -
LinkedHope Intelligent Technologies Co.,Ltd.
PX32101 is a 3U PXI-E system controller based on the newest Intel® Haswell platform. It is designed to provide comprehensive and reliable system controller to support hybrid PXIe-based systems for multiple environments test and measurement applications.Hybrid PXIe-based systems are often required to complete independent diversified complex testing tasks on the PXI test platform. PX32101 provides rich interfaces: 4 USB2.0 / 3.0 for peripheral connectivities; UART for communication or control equipment; dual 1000Base-T Ethernet, one port for LAN connection and the other one for the control of the next generation of LXI instruments. PX32101 can support 4 x4 or two PCIe x8-link, and up to 16GB / s system bandwidth. The ExpressCard 34 expansion slots on the front panel allow users to expand the system modules flexibly. If you install a hybrid multi-slot backplane in the system, then various standard PXI-E and PXI / CPCI peripheral cards could be fitted. In a multitasking environment, PX32101 processor is able to complete multiple tasks independently. The CPU and memory chips soldered with PCB increase reliability performance in shock and vibration environments. Combined with a variety of instrument control interfaces and reliable mechanical & electronic design, PX32101 can meet your hybrid PXIe-based testing for system application requirements perfectly.
-
95-294-001 -
Pickering Interfaces Ltd.
The 95-294-001 Plugin Breakout Module is designed to be fitted to a PXI 40-294 Programmable Resistor Module as part of the Pickering MBoS. The Modular Breakout System is designed to Simplify HILS (Hardware In the Loop Simulation) Applications.
-
LTS8620 -
VX Instruments GmbH
The LTS8620 test system is a modular PXI test system for testing and qualifying laser diodes. The system is able to generate extremely short current pulses. This minimizes the effects of heat on the laser diode.
-
Bridgenorth Signal Processing
PCI, cPCI / PXI : 32 / 64 bit, 33MHz600MHz 6416 DSPFPGA Virtex-II, 1.5 to 6M gatesZBT SBSRAM, 32MB SDRAMExtreme performanceFPGA development supported
-
Marvin GBATS -
Terotest Systems Ltd.
GBATS (Basic Automated Test System) is a preconfigured, modular PXI test platform that addresses analogue, digital, mixed-signal and avionics test needs.
-
NX5300 -
Marvin Test Solutions, Inc.
The NX5300 is a single slot 3U PXI device and interfaces to the unit under test via an On-Chip Debug (OCD) or JTAG port. The NX5300 is a high performance JTAG based background debug mode (BDM) diagnostic system designed for functional test, development, programming and troubleshooting of microprocessor and microcontroller based embedded processor systems. Advanced capabilities include simultaneous support of up to 255 devices on a single scan chain, support of sixteen NX5300 systems controlled by single host machine and configurable JTAG/BDM clock rates up to 24 MHz. The NX5300 includes 16 high-speed measurement channels. Each channel can measure logic levels, frequency, count events and perform a CRC check at rates up to 100 MHz.
-
40-763-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-765-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
95-293-001 -
Pickering Interfaces Ltd.
The 95-293-001 Plugin Breakout Module is designed to be fitted to a PXI 40-293 Programmable Resistor Module as part of the Pickering MBoS. The Modular Breakout System is designed to Simplify HILS (Hardware In the Loop Simulation) Applications.
-
40-763-004 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
95-198-001 -
Pickering Interfaces Ltd.
The 95-198-001 Plugin Breakout Module is designed to be fitted to a PXI 40-198 Fault Insertion Switch as part of the Pickering MBoS. The Modular Breakout System is designed to Simplify HILS (Hardware In the Loop Simulation) Applications.
-
GX1034 -
Terotest Systems Ltd.
The GX1034 offers PXI system designers the capability to develop a system re-certification strategy that employs only internal system resources. By incorporating the GX1034 as part of a system configuration, it is possible to develop a system accuracy verification strategy that can recertify a system’s source and measure baseband instrumentation – resulting in simplified support / maintenance logistics and improved system availability.
-
95-196-001 -
Pickering Interfaces Ltd.
The 95-196-001 Plugin Breakout Module is designed to be fitted to a PXI 40-196 Fault Insertion Switch as part of the Pickering MBoS. The Modular Breakout System is designed to Simplify HILS (Hardware In the Loop Simulation) Applications.
-
40-761-004 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.