Filter Results By:

Products

Applications

Manufacturers

Signal

detectable impulse of electromagnetic radiation or quantum state superposed.

See Also: Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Conditioning, Signal Generators, Signal Meters, Signal Conditioners, Fidelity, Hunting


Showing results: 6976 - 6990 of 8144 items found.

  • Multi-functional CCTV Testers

    GAO Tek Inc.

    GAOTek offers a wide collection of affordable and high quality multi-functional CCTV testers for sale to the United States, Canada and Globally. These simple and convenient multi-functional devices provide monitoring and analytical data when installing and maintaining the CCTV systems for video levels and video signals of the image. The multi-functional CCTV testers capture video images and save the current video frame as JPEG files. Moreover, they are used to record and save current video on a SD card as a record.

  • Online Dissolved Oxygen Controller

    LD-LODC-A10 - Labodam

    Online Dissolved Oxygen ControllerLD-LODC-A10features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.

  • VXI IP Carrier Module

    DP-VXI-5124 - Data Patterns Pvt. Ltd.

    The Data Patterns DP-VXI-5124 is a VXI 'C' size Carrier Board, which occupies a single slot in the VXI system. The module is a register based device with A16/A24/A32 address space and has interrupter capability. The carrier board's VXI bus interface is used to program and monitor the carrier board registers for configuration and control of the board. The VXI bus interface is also used to communicate with and control the external devices that are connected to an IP modules field I/O signals.

  • Ultrasonic Thickness Gauge

    38DL PLUS - Evident Scientific

    The 38DL PLUS is an innovative instrument that signals a new era in ultrasonic thickness gauging. Ideally suited for almost every ultrasonic thickness application, this handheld thickness gauge is fully compatible with a full line of dual and single element transducers. The versatile 38DL PLUS can be used in applications ranging from wall thinning measurements of internally corroded pipes with dual element probes to very precise thickness measurements of thin or multilayer materials with single element transducers.

  • Digital LVDT sensor ZET 7111-L

    ZETLAB Company

    ZET 7111-L is a digital LVDT displacement sensor. It requires no special adjustment and starts measuring right after power is on. Displacement measured values are transferred in digital form via CAN interface. The LVDT digital sensor consists of a primary transducer (LVDT sensor) and a measuring element (ZET 7111-L unit). The LVDT sensor converts meaured object (to which it is mechanically connected) linear displacement  into electric signal to be further transferred into displacement values by the measurement module.

  • SLSC and CRIO Modules and Accessories

    Bloomy Controls, Inc.

    Our approach to delivering a high-quality Aerospace, Automated Test Equipment (ATE) asset begins with leveraging National Instruments hardware and software standard platforms. Beginning with high quality instrument platforms for standard Input and Output (I/O), we leverage NI’s PXI and Compact RIO platforms. Extending these system is NI’s unique platform for Switching, Loads and Signal Conditioning (SLSC), which allow the standard I/O to be customized for high performance aerospace industry applications.

  • SCR Rectifiers

    Carl E. Holmes Company

    SCR-controlled rectifiers are electronically controlled via analog signals for constant voltage and current control. The compact and service-friendly design complies with high industrial requirements and guarantees excellent operational reliability.The input voltage can be from 208 VAC to 600 VAC, 3 PH, 50/60 Hz. Maximum output voltage can be from 6 VDC to 600 VDC. Maximum output can be from 1000 Amps to 100000 Amps. These units can be air cooled, water cooled or oil cooled.

  • Signa; Generator

    MAG-203AD - MCH Instruments Co.,Ltd.

    Features:*Signal frequency:0 .1Hz-2Mhz, continuously variable*Wave form: square,sine*Output attenuator:0dB, 20dB, 40dB,60dB*Output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*Rising and falling edge of square not more than 35ns*Sine distortion less than 1%,amplitude -frequency characterstic:±0.3dB within 100khz, ±1dB above 1Mhz*Frequency meter: 10Hz-30Mhz*Power supply : AC 220V

  • Software

    Digilent Inc.

    Digilent’s proprietary software solutions enable you to communicate with our system boards and a wide assortment of logic devices and use our available analog and digital test & measurement instruments. Refined by customer feedback for years, these powerful and FREE software applications allow you to fully customize your project, from creating and modifying designs for your system board to custom scripting of instruments for capturing, recording, analyzing, and generating mixed signal and mixed domain waveforms.

  • Test for Model-in-the-Loop and Software-in-the-Loop

    RT2 - ETAS GmbH

    ETAS RT2 is a powerful test tool for testing of functional models (MiL) and software (SiL). It contains the following parts of the testing lifecycle: modeling, execution, assessment, and reporting. ETAS RT2 is specialized for testing of embedded systems with inputs and outputs of continuous or discrete signals. A model based test design approach enables intuitive realization of complex test strategies. Thanks to its capabilities ETAS RT2 enables comprehensive testing activities in the early phases of the development.

  • Isolation Amplifier

    Dr. Hubert GmbH

    Isolation amplifiers are indispensable components for signal conditioning. There are several reasons that make galvanic potential isolation necessary. Examples for this are personal protection, on the one hand, as required in medical engineering to ensure contact of persons with life-threatening voltages. On the other hand, different safety aspects, such as protection of IT systems may require the use of an isolation amplifiers. If ground loops need to be separated or if a small differential voltage with a high common-mode level must be determined, the isolation amplifier is the device of your choice.

  • Helium Analyzer

    DTX832-He - Bacharach, Inc.

    The Neutronics DTX832-He Helium in Air Analyzer is for helium in air measurement. With an Ethernet digital communication interface along with 4 to 20 mA output, this analyzer combines ease of use with simple installation, configuration, and integration into DCS and PLC control systems. Used with a well-proven thermal sensor technology that combines the sensor element, signal processing and digital calibration on one small chip, this helium analyzer is an ideal choice for demanding and cost sensitive process control applications.

  • Ethernet Digital Interface OEM Board

    8063 - ICS Electronics

    * Same Digital IO lines as standard 8063. * Same data transfer capabilities as standard 8063 * Digital I/O uses high-density DC-62 connector.* Power connections via 2 screw terminal strip or solder pads.* User configured IDN message and webserver pages makes board respond as part of your system.* Use an ICS Wiring Kit to extend the Ethernet signal to a rear panel RJ45 jack.* Runs on 9 to 32 Vdc power.

  • PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated, 3GHz, 50Ω, MCX

    40-873A-102 - Pickering Interfaces Ltd.

    The 40-873A-102 (PXI) and 42-873A-102 (PXIe) are 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.

  • PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated, 3GHz, 50Ω, SMB

    40-873A-002 - Pickering Interfaces Ltd.

    The 40-873A-002 (PXI) and 42-873A-002 (PXIe) are 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.

Get Help