Product
Multi-Specimen Fatigue
-
TA Instrument’s Multi-Specimen Fatigue Instruments are designed to accelerate fatigue studies for a variety of materials, subcomponents and complete devices. With the capability of simultaneously testing up to 16 specimens at up to 100 Hz, users can generate S/N curves faster and with higher statistical confidence levels than ever before. In this system, proven and refined technologies come together to quickly and confidently deliver results.
-
Product
50 KN Capstan Grips For Heavy Cloth
-
These 50 kN (11,000 lbf) grips use a split drum and capstan to firmly hold specimens that have a tendency to slip, such as heavy cloth and belts, during tensile testing.
-
Product
Pendulum Shock Testing Machine
UDAR-1
-
Pendulum shock testing machine “UDAR-1” is intended for calibration and verification of measuring transducers (both analog and digital) by means of shock impact as well as for shock testing of various specimen.
-
Product
Long-Stroke Tensile Testing System For Vulcanized Rubber
-
Capable of Measuring Even Specimens with a Large Break Strain A tensile test method for vulcanized rubber is stipulated in JIS K6251 (Rubber,vulcanized or thermoplastic-Determination of tensile stress-strain properties). One of the properties of vulcanized rubber is significant elongation. This long-stroke tensile testing system for vulcanized rubber has a long stroke that is required for calculating these tensile characteristics of rubber, and accommodates dumbbell specimens Nos.1 through 6 stipulated in JIS K6251.
-
Product
Martindale Abrasion Tester
SG-P02M
-
This machine is ideal for determining the abrasion resistance of upper, lining, socking, and similar types of shoe materials, particularly those made of fabric. The specimens are capably tested for four bieces or six pieces(option) per time and are rubbed over the abrasive in all directions in a complex, repetitive pattern(a lissajous figure) and, at the same time, the holer totates.
-
Product
Multi-Station Test Frame
6800
-
The 6800 Series Multi-Station System offers enhanced throughput with its ability to perform simultaneous, independent tests on up to five (5) separate specimens using a single load frame. Based on our standard 68TM-30 testing frame (30 kN capacity)*, this system is especially suitable when test times are lengthened due to high elongation or slow test speeds.
-
Product
Walk-in Environmental Chambers
EWS-SERIES
-
Mono-block/Pre-fabricated design EWS-Series Walk-in Environmental Chambers with custom-built features to meet testing needs of large-sized test specimens
-
Product
Averaging Clip-on Extensometer
2650 Series
-
The Instron 2650 Series Biaxial Extensometers are ideally suited for testing a wide range of materials, including polymer matrix composites, metals, and plastics over a range of temperatures. Two sensors measure axial strain on opposite sides of the specimen. Versions are available which provide either a single averaged axial output or 2 independent axial outputs. The extensometers meet the calibration requirements of ASTM E83 class B1, ISO 9513 class 0.5, and ISO 527.
-
Product
Ultra Light High Voltage DC Test Sets
-
This Compact power supply/test set can perform all laboratory and field tests of DC Hipot. A flexible High Voltage Cable is provided at the back for connecting to the test specimen. Available in Rack Mount as well as portable design.
-
Product
Thermal Microscope Stage For Petri Dish
TS-4SMP
-
With our TS-4SMP Thermal Stage for Petri Dish, a specimen on a microscope slide or culture dish can be maintained at any temperature between -20°C and +60°C. Setup is easy, takes little time, and the controller will regulate the stage temperature to within +/-0.1°C. The collar on the stage is designed to accommodate a 35mm 'Nunc' petri dish. The collar may also be removed for use with slides.
-
Product
Vacuum UV Testing Services
-
The system consists of a high-vacuum chamber, multi-ported,equipped with deuterium and xenon sources for accelerated ageing. The specimen to be irradiated is mounted on a temperature-controlled platen, which, in turn is mounted on a XYZ J manipulator. Provision is made for the measurement of emissivity and absorptance without breaking vacuum and at the operating temperature.
-
Product
3-Axis Non-Robotic Automated Testing System
AT3
Test Instrument
The Instron AT3 is a space-efficient, highly adaptable 3-axis mechanical testing platform designed for automated execution of tensile, compression, flexural, and lap shear tests. Built to comply with a broad spectrum of ASTM and ISO standards, it’s well-suited for evaluating materials such as plastics, elastomers, thin films, foils, and metals. The system streamlines the entire testing workflow from specimen measurement and handling to strain measurement and specimen disposal—enabling users to load up to 160 samples and let the AT3 take care of the rest. Boost productivity, reduce manual intervention, and achieve consistent, dependable results with every test cycle.
-
Product
High-Temperature Extensometers < 1000°C Capacitive
2632 Series
-
Is typically used in hot tensile applications with tube type furnaces and consist of a separate measuring unit and suspension arm assembly. The measuring unit uses an LVDT with a fixed travel that remains outside of the furnace, the arms are located mostly inside of the heating system and attach the specimen to the measuring unit.
-
Product
Hot Wire Ignition Tester
-
The HWI test indicates a materials resistance to ignition when exposed to abnormally high temperatures resulting from a component failure such as a conductor carrying far more than its rated current. HWI performance is expressed as the mean number of seconds required to ignite a specimen when wrapped with an energized non-chrome resistive wire that dissipates a specified level of energy.
-
Product
Non-Contacting Video Extensometer
AVE3
-
The AVE3 is Instron’s most advanced extensometer, engineered for high-precision, non-contact strain measurement across a wide range of mechanical tests—including tension, compression, and flexure. Its adaptable design accommodates various specimen types, sizes, and elongation ranges, making it ideal for everything from delicate films to robust metals. By eliminating the need for clip-on devices, the AVE3 streamlines setup and ensures uninterrupted data collection through specimen failure, even in high-energy break scenarios, such as composites. Compatible with environmental chambers and fluid baths, it supports non-ambient testing with ease. With compliance to ISO 9513 and ASTM E83 and a fast 500 Hz data rate, the AVE3 delivers reliable performance for demanding testing standards.
-
Product
Ultra Fast Flexible Implantable Microprobe
IT-23
-
IT-23 Flexible Implantable Microprobe - For ultra fast measurements and for use on micro-size specimens. Time constant 0.005 seconds. Tissue Implantable with a 23 gauge needle (supplied). Fairly fragile. Sensor wires are twisted TFE Teflon™ insulated. Maximum Temperature 150°C. Isolated. Probe diameter .011", 3 foot lead.
-
Product
Advanced Hydraulic Wedge Action Grips
2742 and 2743 Series
-
The Instron advanced hydraulic wedge action grips deliver controlled, constant gripping force using an external hydraulic supply across static and dynamic testing. They support capacities up to 600 kN (static) and 500 kN (dynamic), with interchangeable jaw faces for round or flat specimens. The design ensures jaw face positions remain fixed during gripping (eliminating preload), compensates for changes in specimen thickness, and is ideally suited for use with metals, composites, and plastics.
-
Product
Needle Microprobe
MT-29/5HT
-
Fast-response 29 gauge needle probe, (needle length is 5 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Temperature shock test chambers test
TSS series
-
The operating principle of Schocktestprfschrank based of two superposed test rooms (top hot chamber, cold chamber below), between which a car with the test specimens is moved up and down by the large thermal shock test equipment may be subjected
-
Product
1 N Clip Grips
-
These very low force 1 N (0.22 lbf) clip grips are for tensile testing fibers, tapes, and other similar shaped specimens. They are designed for use with 50 N (11 lbf) and below load cells.
-
Product
Heat Deflection Tester
-
Apparatus is used to determine the Heat Deflection Temperature or the Vi cat Softening Point. All the specimens are charged with a constant load and immersed in a bath, where temperature is increased at a standard velocity. The attained heat resistance rate of plastic materials is a widely required parameter for product characterization, for quality control, as well as for evaluating their conformity to the previewed applications.
-
Product
Concrete Water Impermeability Tester
-
The concrete water impermeability testing system is designed with many different standards in mind including DIN 1048, ISO/DIS 7031, EN-12390-8 & UNI 9533. This impressive piece of machinery comes in different models with either 3 or 6 measuring points and with or without quantitative measurement of water permeability. The supporting structure is very stable and is at a convenient height to allow the easy access. The pans are made out of stainless steel, the specimens are easy to insert due to the clamping device.
-
Product
Cryostats
attoCRYO
-
Fundamental research in physics, as well as specimen characterization in materials science often require the use of (ultra) low temperatures. Many phenomena also involve the application of high magnetic fields, usually generated by superconducting magnets. attocube provides a broad portfolio of versatile cryostats for sensitive measurements at variable temperatures and extreme conditions.
-
Product
Specimen Radiography System
XPERT 40
-
Whether in the biopsy suite or the pathology lab, nothing beats the XPERT 40 Specimen Radiography System in terms of versatility and speed. A 50kV, 1.0 mA X-ray penetrates the densest cores and surgical specimens, identifying the finest details in seconds.
-
Product
Moisture Management Tester
-
Sataton Instruments Technology CO., Ltd
Moisture management tester (MMT) is the tool for the measurement, evaluation and classification of liquid moisture management properties of textile fabrics. By testing the changes in electrical resistance of textiles placed between two horizontal electrical sensors with concentric pins, the tester can calculate fabric liquid moisture content changes that quantify dynamic liquid moisture transport behaviors in multiple directions of the specimen. The software of tester can grade the liquid moisture management properties of a fabric by using the predetermined indices. The tester is used to determine the liquid moisture management properties of knitted, woven and nonwoven textiles, and also can be used to test the one-way transport capability of diapers.
-
Product
Resistance Measuring Equipment
-
measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.
-
Product
Paper Thickness Tester
DRK107B
-
Shandong Drick Instruments Co., Ltd.
DRK107B Paper Thickness Tester is applied to testing the thickness of paper specimens.
-
Product
Extensometers
-
Extensometers measure strain, the change in length of a specimen divided by the original length (gauge length) of the specimen. Tinius Olsen offers wide range of extensometers based on your testing needs including video, optical and physical contact with specimen.
-
Product
Back Pressure Spring For Vacuum Adapter
-
The counterpressure spring for vacuum adapters ensures that the board carrier plate with the test specimen is lifted off the needle bed at the end of the test.
-
Product
Pneumatic Flat Grips
-
For tensile testing rubbers, plastics, elastomers, textiles, cloth, and paper, in specimen geometries such as plates, films, and wires, a good option is pneumatic flat grips. Quick clamping and a repeatable clamping force are advantages of pneumatic flat grips.