Filter Results By:

Products

Applications

Manufacturers

Model

construction of a concept.

See Also: Modeling, Modelling, Modelers, Human Body Model, Charged Device Model


Showing results: 3661 - 3675 of 4104 items found.

  • PXIe Vector Network Analyzer, 300 kHz to 20 GHz

    M9374A - Keysight Technologies

    Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration

  • PXIe Vector Network Analyzer, 300 kHz to 6.5 GHz

    M9371A - Keysight Technologies

    Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration

  • Low Resistance Ohmmeters

    Megger Group Ltd.

    Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.

  • Tap Changer Analyzers & Winding Ohmmeters

    IBEKO Power AB

    Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints

  • XRF

    L Series - Bowman

    The L Series is the most versatile instrument that Bowman offers. It combines all of the features of the P Series with a larger sample chamber and greater X-Y stage travel. For samples larger than ~12 inches (300 mm) in any direction, the L Series is a must-have. The large sample stage and travel allows for both large parts, or large sample fixtures holding multiple parts, to be measured. The chamber is fully enclosed and boasts a capacity to hold samples up to 22″ (550mm) x 24″ (600mm) x 13″ (330mm) (LxWxH). The X-Y stage travel distance is 10″x10″ (254mm x 254mm). The standard configuration includes a 4-position multiple collimator assembly, and a variable focus camera allowing for measurement in recessed areas. As with other models, the collimator sizes and focal distances are customizable for different customer applications. The programmable X-Y stage is included, but can be removed to allow for the maximum sample height capacity (10″ (254mm) z-height with stage, 13″ (300mm) without). The solid-state PIN detector is included along with our long-life micro-focus x-ray tube. The high performance SDD detector is an optional upgrade.

  • AC-DC Wide Adjust Output Power Supplies

    Acopian Technical Company

    *Universal input.*Power Factor Correction.*Output Inhibit*Constant voltage and constant current modes.*Voltage and current monitor terminals.*Voltage and current programming capabilities.*Short circuit and overload protection.*Thermal protection.*Low Profile.*No minimum load required.*Adjustable down to 0 volts (‘Wide Adjust’ models).*Internal EMI Filter and RFI Shielding.*Pluggable connectors for input and control wiring.*Remote Sensing.*‘Vout OK’ signal monitor.*‘Soft start’ operation.

  • Digital Multimeter

    MM-2 - Dwyer Instruments Inc.

    Our compact, low cost Model MM-2 Digital Multimeter with True RMS is ideal for general electrical testing and troubleshooting. This full function multimeter measures DC voltage to 1000 V and AC voltage to 750 V, DC and AC current to 10 A and resistance to 400 Ohms. In addition to volts, amps and ohms, this meter includes audible continuity, diode, LED and transistor hFE tests. The rotary switch allows you to select from any of the functions quickly and easily.

  • CableEye® HV-Rated QuickMount™ Housing for CAMI Connector Boards

    CBH2 - CAMI Research Inc. (CableEye®)

    CAMI Research Inc. (Acton, MA) has released a High-Voltage (HV)-rated QuickMount housing (CBH2) for its CableEye® automation-ready, cable and wire harness testing systems. As a free-standing, quick-release board fixture, it allows users to connect CAMI’s test interface boards to the 64-pin headers of any expansion module - even at some distance. The housing may be used with any CableEye model and is rated to 2100 Vdc / 1500 Vac.

  • 6/8/12 Volt 0-1000 Amp Heavy-Duty Variable Carbon Pile Load Tester

    7136R - Associated Equipment Corp.

    • High-volume testing and fleet use• Tests 6/12 Volt batteries• 1000 Amp load; tests batteries up to 2000 cold cranking amps• Built in LCD Digital Voltmeter and LCD Digital Amp Meter• Cools with high RPM fan for continuous battery testing• High resolution carbon pile assembly for smoother operation and longer life• Optional Model 6038C for added mobility with convenient heavy-duty cart with wheels• RoHS and CE Compliant• Made in USA of US and Global Components

  • PXI Multifunction I/O Module

    NI

    The PXI Multifunction I/O Module provides I/O with varying numbers of channels, sample rates, and output rates with precise timing, triggering, and synchronization between models. This module can be used for industry applications such as laboratory research, design verification test, and manufacturing test.The PXI Multifunction I/O Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • LED Optical Aging Test Instrument

    LEDLM-80PL - Lisun Electronics Inc.

    LEDLM-80PL LED Lumen Maintenance and Aging Life Test System is designed according to standards of IES-LM-80, IES-LM-82, TM-21 and GB2312-80, and the software is developed base on Arrhenius model. LED has the features of long life, but with the different working condition and drive current, its life will be different, but generally the life will be around 50K hours. Differ from the traditional lightsource, LED light will decay gradually rather than extinguish instantly, so in the standard of LM-80, it introduces L70, L50 and etc.

  • Energy and Traction Control

    Mors Smitt Group

    ‘MSAV is a system to measure high current and high voltage for energy and traction control management, both for new-built and retrofit railway applications’ The international railway market is focused on minimizing the carbon footprint by optimising the use of natural resources and energy. Deregulation of the railway infrastructure requires a different way of working and tools to support new business models in the railway industry the European EN 50463 standard sets new requirements for energy measurement and the calculation of the interoperability cost of rolling stock.

  • Crack Opening Displacement (COD) gauges

    COD - Instron

    Instron® Crack Opening Displacement transducers are designed specifically to perform standard ASTM and ISO fracture mechanics tests (both cyclic and static), covering all common specimen geometries (CT, SEB, Centre Crack, Arc Shaped). Each model offers class leading linearity, whilst being rugged enough to withstand the high energy release common in many of these applications and can be used at both elevated and sub-ambient temperatures. These gauges comply with requirements laid down in ASTM E399-09.

  • Digital Fiber Sensor

    FX-500 Ver.2 - Panasonic Industrial Devices Sales Company of America

    Thanks to its new “application-specific integrated circuit” (ASIC), Panasonic can solve applications with Fiber Optic Sensors that were previously impossible. Not only can the FX-500 Series reach a response time of 25µs while providing extremely accurate detection, integrated logic functions save you money because external controllers are no longer needed for normal applications and threshold tracking and self-diagnostic functions save time for maintenance. Moreover, the reliability of the detection has increased by 75% compared to that of previous models.

  • Transformer Winding Resistance Meters

    TWA Standard Series - Amperis sl

    The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.

Get Help