  • Small Motor Dynamometer

    90407 - HITEC Sensor Solutions Inc.

    The Model 90407 Conveyor Test Stand by Sensor Developments Inc. is a device used for testing operational parameters of a conveyor motor/roller.  The system operates the conveyor motor/roller and performs loading operations, while recording all of the important motor/roller parameters for later analysis.

  • Digital Insulation Tester

    DIT-1020 - Laxtronics Instruments & Controls Pvt. Ltd

    Digital insulation tester Model No: DIT-1020 is designed to carry out electrical insulation measurement in delicate or sensitive electronic sensors, transducers, modules and assemblies with test voltage of 100 Volts DC, its short circuit current is less than 500uA.

  • Sentry Hipot Tester AC/DC/IR

    19070 - Chroma Systems Solutions, Inc.

    The Sentry 19070 Hipot Tester series provides 2 models to choose from. The Sentry 19071 for AC Hipot testing; and the Sentry 19073, which combines both AC and DC Hipot with insulation resistance (IR) measurements into a single compact unit.

  • Desktop PCB Test System

    BOARDWALKER 9627 - Qmax Test Technologies Pvt. Ltd.

    QT9627 is a cost effective entry level model Desktop PCB Test System. It can be configured to maximum 64 Channels of In-circuit Functional Test Channels and 64 Channels of QSM V-I Signature Test .Maximum Digital Test Speed 10MHz in the QT9627 .

  • Time Domain Analysis

    S93010B - Keysight Technologies

    The S93010B time domain capability allows you to measure the time domain response of a device. The analyzer can transform frequency domain data to time domain or time domain data to the frequency domain and runs on PNA/PNA-L/PNA-X Series B models.

  • Digital Panel Meter

    Nippen Electrical Instruments Co.

    To be supplied with the right meter, simply furnish the following details in your order: Model Number, Description of the Meter. Accuracy Class. Voltage Input (110 Volts from PT, 240 Volts line to neutral or 415 Volts Line to Line). PT Ratio specifies the High Voltage Primary first ( 33 kV.110V). Current input (5Amps or 1 Amp secondary ) CT ratio (e.g. 100/5 Amps. etc.). Aux. Supply : 50/60 Hz (240VAC of 110/VAC). Dimension : 96 x 96mm or 48 x 96 mm or 144 x 144 mm.

  • Electromechanical Switches DC to 40 GHz

    Fairview Microwave Inc.

    Fairview Microwave’s electromechanical switches exhibit extremely low insertion loss repeatability with guaranteed levels of 0.03 to 0.05 dB over 5 to 10 million switching cycles, depending on the model. Performance includes low insertion loss of 0.3 dB with high isolation of 100 dB typical, and input power ratings of up to 70 watts CW and up to 1 watt for hot switching applications. These switches cover broadband frequencies from DC to 40 GHz and are offered in three configurations: single-pole double-throw (SPDT), single-pole four-throw (SP4T) and single-pole six-throw (SP6T).

  • Explosion-Proof Differential Pressure Switch

    1950G - Dwyer Instruments Inc.

    The Model 1950G Explosion-Proof Switch combines the best features of the popular Dwyer Series 1950 Pressure Switch with the benefit of natural gas compatibility. Units are rain-tight for outdoor installations, and are UL listed for use in Class I, Groups A, B, C, & D; Class II, Groups E, F, & G and Class III atmospheres, ATEX for EExd IIB & Hydrogen T6, and CSA & FM approved for Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G and Class III atmospheres

  • Finite Element Analysis

    Response Dynamics Vibration Engineering, Inc.

    An understanding of structural dynamics is very important to sound Finite Element Analysis (FEA). We have been performing FEA analysis for over 30 years and in most cases we have used experimental data to guide our modeling. While our engineers have had undergraduate and graduate courses in FEA, it is the years of modeling and analysis of existing structures that has taught us the most by forcing a thoughtful analysis of the key structural dynamics and then going though the process of making adjustments to boundary conditions, expanding the dynamics of the model in places, and making simplifications and approximations where possible.

  • General Purpose Heat Flow Meters

    TA Instruments

    Thermal conductivity defines a material’s ability to transfer heat. A precise and accurate measurement is critical for any process or material experiencing large or fast temperature gradients, or for which the tolerance for temperature changes is exacting. Accurate values are essential for modeling and managing heat, whether the component of interest is called on to insulate, conduct, or simply withstand temperature changes. Information about these properties are routinely used in heat transfer models of all complexities. Thermophysical property measurements also reflect important information about material composition, purity and structure, as well as secondary performance characteristics such as tolerance to thermal shock.

  • Hazardous Location Sensors

    S88 - Electro-Chemical Devices

    The S88 pH Sensors are one part of the Model S88 Intelligent Sensors product line. The S88 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S88 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S88 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation from the factory.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • Precision Thermometer

    F252 - ASL

    ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.

  • Ultra-High Precision Motorized Vertical Stages

    ZOLIX

    Model: KSAV Ultra-High Precision Motorized Vertical StagesKSAV1010/2030-ZF is new product, wedge vertical stage with.high-resolution, so many advantages: high-stability, high-load and capacity in vertical position,self-locking.applicatin filed: high postion precision,high load capacity,limited space and so onCharacteristic ◆Cross ball screw rail,precion ground ensure resolution, straightness,high load capacity, limited space◆small travel improve resolution◆stepper motor and DB9 interface, choose controller flexibility◆switches ensure safe when operate◆ planning other specification and size

  • Averaging Pilot Tubes

    Meriam Process Technologies

    Meriam manufactures the widest range of Averaging Pitot Tubes for gases, liquids and steam with bi-directional flow capability. Under the Accutube brand name, there are four standard models; Inline, Insertion, Flanged and Wet Tap which can provide a flow solution for your toughest applications. To provide the complete flow solution that meets your specific needs, we can provide DP or Multivariable transmitters from the brand of your choice, or we will recommend the best fit for your application. These transmitters can be installed on the Accutube and configured to your specific flow requirements here at Meriam by qualified technicians, reducing your expense and time .

Get Help