Showing results: 961 - 975 of 4091 items found.
-
-
DT-D Series -
TDK-Lambda Corp.
*DoE, CEC and EISA Compliant*Energy efficiency level V and VI models*Wide Range AC Input
-
Ektron Tek Co., Ltd.
PL-2000X Plunger Testers equipped with servo-hydraulic system to control the testing speed. Available for customers to select suitable model.
-
35 -
Picoprobe
The Picoprobe Model 35 has been engineered to meet the stringent demands of advanced high frequency circuit designers.
-
Columbia Research Laboratories
This group of accelerometers is made up of the 3000 and 5000 Series. The 3000 Series are standard size units, including many with all welded construction, that are hermetically sealed for use in dirty and humid environments. The 5000 Series are smaller and lighter in weight than standard units. Characteristics are almost identical except that with miniature units higher natural frequencies and shock levels can be obtained due to their inherently reduced mass. Sensitivities, however are somewhat lower. High Temperature models are available that operate to +500°F. For best performance use with the Columbia Model 4601 Charge Amplifier or Model 5810 Inline Charge Converter.
-
Pentek, Inc.
member of the Jade" family of high-performance data converter XMC modules based on the Xilinx Kintex Ultrascale FPGA. The Model 71132 is an XMC module featuring eight 250 MHz 16-bit A/Ds with eight wideband digital down converters (DDCs) and 64 multiband DDCs, all fully programmable. The Model 71132 doubles the number of A/D channels and DDCs over previous models giving this the best price per channel ratio in the product family. Applications monitoring a broad spectrum with a need to quickly analyze specific portions of the identified spectrum can greatly benefit from the capabilities of the 71132.
-
450 -
Oersted Technology
The Model 450 is a high-resolution, laboratory gaussmeter, capable of measuring magnetic fields from 0.001 Gauss to 300k Gauss (measurement range is dependent on probe used). This unit is designed for demanding applications, such as material analysis and field mapping, where low-noise, high-resolution magnetic measurements are necessary. Measurements of AC and DC magnetic fields are shown in Gauss or Tesla on the two-line vacuum fluorescent display. The Model 450 features RS232C and IEEE-488 ports, allowing the instrument to be controlled via a remote computer or automation equipment. A hall-effect gaussmeter probe is included with the Model 450, and may be selected from an extensive line of probe
-
ERAVANT
SAGE Millimeter wave rectangular gain horns, also called pyramidal gain horns, are offered as both standard and custom models with a rectangular waveguide interface. The pyramidal gain horns only support linear polarization. With a calibrated gain chart, these horns can be used to measure the gain of other antennas by comparing the generated signal levels of both. For this reason, these horns are also referred to as standard gain horns. The listed models offer 23 dB nominal gain, 10/11 degrees typical half power beamwidth and 14 dB/30 dB typical side lobe levels at the center frequency of the band. These horns cover full waveguide bandwidths within the frequency range of 8.2 to 170 GHz. In addition to the models listed below, models with 10, 15, 20 and 25 dB gain and other frequency bands are also available.
-
WHMB Series -
Farran Technology Ltd
Farran Technology manufactures a comprehensive range of waveguide harmonic mixers for use with industry standard spectrum analysers and other custom applications. Models WHMB are fully calibrated broadband balanced diode units covering 26.5-110 GHz in standard waveguide bands. We also offer a low cost general purpose model WHMP covering 26.5-170 GHz.
-
8800 Series -
Venable Instruments
The analyzer utilizes a digital “Sync” signal to provide synchronization between analog and digital hardware. The Model 8800 performs simultaneous analysis on both analog input channels and digital target processor, reliably capturing all data. Versatile by design, the Model 8800 digital interface can be disabled, via software, to use the analyzer in a standard 2-channel, analog-only configuration.
-
Models CLK4 & CLK6 -
Laurel Electronics, Inc
4-digit model (CLK4) with HH:MM display, or 6-digit model (CLK6) with HH:MM:SS display. Large-digit displays with a digit height of 2.2" (57 mm), 4.0" (102 mm), 5.7" (144 mm), 7.9" (200 mm), or 11.0" (280 mm) for long viewing distances. Optional relays and data I/O. Choice of display brightness and cases for indoor or outdoor mounting.
-
Traction Wheel Assembly -
Electro-Sensors, Inc.
The complete and ready-to-install system converts linear travel/speeds to square-wave pulses/frequencies. • Square-wave frequency output, NPN open-collector • 5-28 VDC powered • 1 to 1,270 pulses per revolution (PPR - specify when ordering) • Optional bi-directional (quadrature) output models • 3 models: black neoprene rubber, smooth polyurethane, and diamond knurled aluminum tread
-
Vektrex Electronic Systems
The Vektrex SpikeSafe DC Current Sources provide reliable drive for LED/laser diode reliability, IESNA LM-80 test, and other current-driven test applications. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, precise current, and high power density — typically 6.4kW-8kW.
-
370 -
Lake Shore Cryotronics, Inc.
The Model 370 AC Resistance Bridge is designed for precise, accurate, low noise, low excitation power AC resistance measurements. Its primary application is the measurement of resistive materials in cryogenic environments from 20 mK to 1 K. Fully integrated, the Model 370 includes features to reduce and control noise at every step of the resistance measurement process
-
TE2504 -
Ajinkya Electronic Systems
Ampere Hour Meter Module- Model TE 2504 is basically managed for ready setup or the usage can be seen in where the current requirement are low. This one is used which is ready to be applied in the stand alone panel and advanced from all the former models, IM2501, IM2502 and IM2503. These are basically panel mount instruments which are required to rectified in the rectifier or in an independent panel.