Showing results: 421 - 435 of 821 items found.
-
Pacific Millimeter Products
These waveguide bandwidth harmonic mixers are designed for use with spectrum analzyers with diplexers, such as the Tektronix 492 and 494 and the Hewlett-Packard 8555A, 8565A and 8569A. They are also used as phase locking and receiver mixers for antenna measurement systems such as the Scientific Atlanta wide range receivers. When used with an external diplexer*, these harmonicmixers can be used to phase lock millimeter wave sources.
-
ATU's -
LBA Group, Inc
LBA medium wave AM Antenna Tuning Units (ATU) and Line Tuning Units (LTU) are impedance matching units designed to match the transmitter to the impedance of the transmission line or the antenna system. Our Antenna Tuning Units are available for both series-fed and {ln:Tunipole antenna systems} Tunipole™ antenna systems to powers in excess of 500 kW.
-
Guided Wave
The sample interface is a virtual “windows into the process” and is a critical component of any optical analyzer system. Guided Wave sample interfaces (probes, flow cells) are designed for use with NIR or UV/Vis fiber optic coupled analyzers. They are designed to be rugged and reliable in harsh chemical and physical process conditions while providing optimal transmission for long-term reliable measurements.
-
DMXE -
Elmika
The DMXE Detector Mounts are broadband devices designed for operation in millimeter wave range. The Detectors are optimized for broadband performance and are used in mm-wave test setups to detect, monitor and measure modulated signals.The DMXE Detector Mounts use Schottky Barrier packaged diodes and are provided in five waveguide bands between 33 GHz and 225 GHz.
-
PE8203 -
Pasternack Enterprises, Inc.
Pasternack adjustable phase trimmer PE8203 is part of our large selection of in-stock RF, microwave and millimeter wave components available for purchase. This adjustable phase trimmer is manufactured with SMA connectors and has a phase adjustment of 10 degrees. Our SMA adjustable phase trimmer has a minimum frequency of DC and a maximum frequency of 18 GHz.
-
CDN-58A4 -
Shanghai Sanki Electronic Industries Co., Ltd.
CDN-58A4 signal line/data line coupling decoupling network, suitable for surge pulse and ring wave pulse unshielded symmetrical communication line, according to the new standard IEC61000-4-5.Ed3. Appendix A Figure A4 design. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.
-
VOLTA -
Innerspec Technologies, Inc
VOLTA features a patented pulser technology to satisfy the most energy-demanding EMAT applications in a compact and rugged package. Standard software built on Innerspec Technologies Operating Platform (ITOP) includes an intuitive menu to set up any EMAT application using standard sensors from Innerspec’s catalog for normal beam, angled beam, and guided waves.
-
CTS Valpey Corp.
Piezo elements form an essential component in medical diagnostics. Medical Ultrasound uses high-frequency sound waves to look at organs and structures inside the body. Medical professionals use medical ultrasound to view internal organs and during pregnancy to view the fetus. CTS provides both monolithic and composite piezoelectric elements used in medical ultrasound applications.
-
L722 -
Wagner Electronics
The Model L722 Stack Probing Sensor coupled with the L612 Digital Recording Moisture Meter makes it easy to reach deep into stickered units of lumber and take accurate moisture readings without the danger of broken pins. Wagner''s electromagnetic wave technology makes it possible to take multiple readings throughout an entire stack in just minutes.
-
TA-902 -
Tech-Aid Products
This is our latest API model and it comes packaged in a one-eight DIN size extruded aluminum enclosure. This size allows for direct replacement of other panel mounted API's for a more compact panel mount option. This unit has same features as our TA-900 unit and can be modified to work with non-standard square wave references as in theS-TEC 6443.
-
HH2103 -
Colluck Company Limited
Basic Accuracy 1.0%. LCD display 2000 count, 12.8mm figure height. Manual Ranging at your choice (19 Range). Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 2000KΩ. Diode test. Square Wave Signal Injection
-
Analog Devices Inc.
Analog Devices portfolio of single, double, and triple balanced mixers offers the most fundamental and versatile frequency mixing components to meet the varied needs of RF, microwave, and millimeter wave applications. This product family helps designers meet their specific design objectives, and ADI offers a wide range of mixers with both die and packaged options available.
-
Teledyne RF & Microwave
Gain Shape Linearizer Amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run, or perhaps changing the input gain response to a MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
WaveSignal™ -
Rutter
sigma S6 WaveSignal™ is a radar-based wave system that delivers real-time prediction of quiet period operational windows, providing valuable information to mariners. Within a three-minute horizon, WaveSignal™ identifies quiet periods by displaying a simple red [stop] or a green [go] signal light indicating when to suspend or resume operations with confidence.
-
Techimp HQ S.r.L
It is a deeply customizable test bench which is suitable to generate frequency and amplitude controlled voltage. This test bench could be used for life test or quality test on samples or devices. It can be configured both for sinusoidal test (STANDARD version) and both for square wave or pulse test (TechSQUARE). It includes safety systems for avoiding overload and incorrect use.