Showing results: 496 - 510 of 821 items found.
-
US Technologies, Inc.
UST specializes in the testing, repair and refurbishment of all types of RF amplifiers (broadband and narrowband), microwave amplifiers and millimeter-wave amplifiers: solid state, thin film, traveling wave tube (TWT), low noise RF amplifiers, intermediate power RF amplifiers, limiting RF amplifiers, doubler RF amplifiers, driver RF amplifiers, variable gain RF amplifiers, and active frequency multipliers.
-
T3AWG2K -
Teledyne LeCroy
he T3AWG2K series consists of two affordable dual-channel arbitrary waveform generators, 16-bit vertical resolution, 6 Vpp output voltage (50Ω to 50Ω), 128 Mpts/ch memory, a maximum sampling rate of 600 MS/s and a maximum sine wave frequency of 150 MHz. The T3AWG2152-D mainframe adds 8 synchronized digital channels to the analog outputs, ideal for debugging and digital design validation.
-
Qualitrol
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
Model 308 -
OAI
Dependable and repeatable, The OAI Model 308 UV Intensity/Power Meter is precise, direct-reading instrument designed to measure UV light intensity. The Model 308 features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port and is available with an optional software package that facilitates instant data logging of intensity mode, time, wave length, serial number and calibration due date.
-
40-763-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-765-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-763-004 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-761-004 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-767-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
KD 688 A -
King Design Industrial Co., Ltd.
*PLC control, linear motor fast speed control the height setting.*Alarm warning before testing.*Light support structure decreases the test impact.*Support dropping very smooth with dual lubrication guide.*No second impact. *A data acquisition for the impact wave record (Option).*Non maintenance request for continue operation.*According to ISTA, ASTM .....etc international standard.*Equipped edge & corner holder.
-
MIG0603CAP -
EMC Partner AG
The MIG0603CAP consists of two circuits with impulse capacitance 20 µF and 0,25 µF. Both circuits generate a voltage wave shape 1,2/50 µs and are combined in a 4 unit height 19" rack. The generator circuits are defined in IEC 60384-14 and EN 132400. The serial resistors Rs, the impulse capacitor CT, and the load capacitance Cp will be automatically switched when different capacitance ranges are selected on the MIG0603CAP.
-
XRC -
KEYCOM Corp
KEYCOM develops various radars for versatile applications based on its knowledge and expertise on millimeter wave and microwave technologies. KEYCOM’s product line of radars includes Radar Test Systems (RTS) to evaluate distance accuracy or output, Radar Alignment Systems (RAS) to help you adjust the alignment of radars, and Radar Cross Section (RCS) measurement systems to measure RCS of such radar targets as aircraft, ships and automobiles.
-
CD16 -
Validyne Engineering
The CD16 Miniature Carrier Demodulator is designed to deliver a 0 to 5 Vdc output from a variable reluctance transducer and operate from unregulated 9 to 55 Vdc power. A square wave excitation of 5 kHz is furnished to the transducer and the solid state integrated circuit amplifier and demodulator converts the transducer signal to an analog dc output. Zero and Span adjustments are made through access holes in the case.
-
MVG EME Guard XS 6GHz -
LBA Group, Inc
The EME Guard XS is an RF measuring device to alert workers near RF emitters for protection of climbers and other RF-exposed workers. It continuously scans for electromagnetic waves and, via its built-in alarm and visual system, alerts users whenever the acceptable pre-selected limits have been exceeded. This RF Safety PPE is extremely easy to use and supports a safer working environment in the areas of installation and maintenance.
-
bsw TestSystems & Consulting AG
Up To 1.5THz For Network Analyzers Modern communication standards, like for instance 5G, place high demands on components (mixers, amplifiers, antennas, etc.), which have to be examined in high frequency bands (millimeter waves); the requirements include: broad frequency coverage, sufficient output power to operate the components under compression, high dynamic range and stability as well as a reduced dynamic content within the spectrum.