Filter Results By:

Products

Applications

Manufacturers

Resistance

that which keeps current from flowing freely.

See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire


Showing results: 1201 - 1215 of 2667 items found.

  • CableEye Tester Calibration Verification Board | Cable & Harness Tester

    CB50 - CAMI Research Inc. (CableEye®)

    Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently. Certain components within models M3U, M3UH, HVX, and HVX-21 (i.e. those capable of measuring resistance) are analog components whose characteristics change slightly over time. This aging is a natural phenomenon common to all electronic components and may cause resistance measurements or gradually deviate from normal. A tester that is out of calibration will give inaccurate results. Some (maybe all) resistance measurements will be incorrect. Consequently, it may Pass what should Fail and, conversely, Fail what should Pass. In other words product yield will be contaminated due to unreliable quality.

  • Armature Tester

    Qingdao AIP Intelligent Instruments Co., Ltd

    This tester is suitable for online or offline detection of various armature electrical properties, such as power tool motors, garden tools, vacuum cleaner motors, small household appliance motors, automobile motors, fitness equipment motors, permanent magnet micro-motors, etc. The tooling of the tester meets the requirements of arbitrary placement of the armature, and can automatically and accurately sort/track faulty solder joints; the equipment startup methods include buttons, remote control, and sliding cover; it meets the armature test of special processes such as double insulation, and automatically identifies solder joints, winding short circuit/open circuit , winding errors, poor welding and other problems; the tester can also automatically count the number of tests, the number of defectives and other data, which is convenient for quality management analysis.The tester test items mainly include:bar-to-bar resistance, diagonal resistance, welding resistance, insulation resistance, ac hi-pot, surge.

  • Production Line Test System

    1740 - STS Instruments

    The fully programmable Model 1740 facilitates high speed, production line testing in both automated and manual applications. Standard tests include AC Hipot, DC Hipot, Resistance, patented Tang-Weld Resistance and Surge. Robust software offers automatic setup of all test parameters, complete result storage, Go/No-Go testing requiring no operator judgment, and online statistics for all tests.

  • Multifunction Meter for Electrical Installations

    AMPI-530 - Amperis sl

    Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD

  • Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems

    ZX3 - Allied Edison LLC

    The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.

  • Line Loop Tester

    8455 - Simpson Electric Company

    Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks. 

  • Low Noise Test Cables For N1413 With B2980 Series, 1.5 M

    N1427A - Keysight Technologies

    The N1427A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It comes with a separate triaxial (special screw-type) female connector and a High Voltage BNC (special type) female connector. This allows terminal configuration to be converted to any other configuration. Therefore, custom test fixture can easily be constructed. The N1413A High Resistance Meter Fixture Adapter is also required to connect the N1427A to the B2985B/87B.

  • Leak And Seal Strength Detector

    LSD-02 - Jinan Leading Instruments Co., Ltd.

    LSD-02 Leakand Seal Strength Detector is applicable in the quantitative measurement of leak, heat seal strength, heat seal quality, and burst pressure of each heat sealedges of the flexible packages that are made using heat seal and adhesiveprocessing, as well as sterilized packages; the quantitative measurement ofleak performances of all kinds of plastic pilfer-proof closures; thequantitative measurement of the unitary airproof, compression resistancestrength, cap body joint strength, cap disengaging strength, seal strength ofedge and butting strength of various flexible tubes. It can also provideevaluation and analysis for the compression and burst resistance strength ofthe materials of flexible packaging bags, the torsional airproof index of cap,the cap joint and disengaging strength and the stress strength; as well as theairproof performances, the compression resistance performance and the burstresistance character of unitary bottle, etc.

  • Passive Component ATS

    Chroma ATE Inc.

    Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe

  • Trip Amplifiers

    Datexel

    Datexel manufacture a large range of Trip Amplifiers and Process Limit Alarms that accept universal inputs and provide either relays or NPN or PNP transistor outputs. The DAT5028 is also an isolated signal converter and has a local display with up to 4 relays and is DIP switch programmable. The inputs can be Thermocouples, RTD, mV, mA, Resistance, Potentiometers or Voltage. They can be supplied fully configured set up by PC or DIP switches. The DAT5024 is a trip Amplifier / Temperature limit alarm for RTD's, Thermocouples, Voltage, Resistance and Current with the option of 1 or 2 relay outputs hysteresis and delay timers. The DAT5024 E range is an economical choice with DIP Switch programmable for voltage or current input. Either 1 relay or 2 relays (SPDT) are available with delay timers.

  • Circuit Breaker Analyzer

    CBA 3000 - Altanova Group

    CBA 3000 allows any timing test, motion and speed analysis, multiple contemporary static and dynamic contact resistance measurements, both sides grounded (BSG) tests, undervoltage condition test and more. All these functions are integrated in a single lightweight test case without the need of connecting additional external modules.

  • DC to 100MHz

    1394A - Ballentine Laboratories, Inc.

    Nominal Heater Current: 5 mA rms,Max. Heater Current: 7.5 mA rmsCouple Output: 7 mV ± 12% at nominal heater current.Couple Resistance: 8 W ± 20%.Maximum DC Reversal Error: ± 0.04%Couple Output Voltage to Heater (ground): ± 50 V (dc + acpk-pk) max.

  • Digital Clamp-on AMmeter / Multimeter

    HH2099 - Colluck Company Limited

    3-1/2 digil Large LCD display 2000 count with symbolic signs. CAT II 600V rated. Basic accuracy 0.5%. Auto Ranging High Voltage test up to 600V DC and 600V AC. Higher Current test up to 1000A AC/DC. Measure Resistance up to 20MΩ

  • Double Bellows Differential Pressure Switch

    DP - Dwyer Instruments Inc.

    Two opposing bellows in the Model DP differential pressure switch result in maximum sensitivity, quick response to changes and good vibration resistance. Choice of brass or 316 stainless steel assures broad media compatibility. Setpoint adjustment is easy thanks to external knobs and large, clear scale reading directly in psid.

  • EBIRST 23 X SMB Verification Fixture

    93-011-101 - Pickering Interfaces Ltd.

    The 93-011-101 23 x SMB Verification Fixture is an accessory for the eBIRST range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.

Get Help