Resistance
that which keeps current from flowing freely.
See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire
-
Product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25UN-6
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1R1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
50Hz-100kHz LCR Meter
11022/11025
-
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
Product
PXI Precision Resistor Module 9-Channel, 1.5 to 3.55k
40-297-023
Programmable Resistor Module
This 9-channel PXI Precision Resistor Module provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-297 series is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. It is particularly well suited to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.
-
Product
Alternate 2.50 (71.00) - 5.80 (164.00) General Purpose Probe
P2665G-2W2S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
KV CAPS
500 V
-
Macom Technology Solutions Holdings Inc.
The MACOM KV CAPSTM Si high voltage capacitors feature very high working voltage ratings, very low loss and excellent stability by virtue of their novel internal construction and very high-quality dielectric layers. These capacitors are available as unpackaged chips. The chips have gold bonding surfaces on both terminals to enable excellent bonding and minimum contact resistance.
-
Product
Doide Testers
-
Specialized test for Axial, SMD and 2-pin package type.Electrical Testing: Forward:VF Reverse:VZ、DVZ、IR、ACIR、DIRFour-wire measurement and contact resistance in case of deviation.Manual test or conjunction with automatic machine.
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2E-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
In-Circuit Test (ICT)
-
Analog components (resistance, capacitance, inductance, diodes, transistors, etc.) as well as complex digital components can be tested in the ICT. Compared to other test methods (e.g. flying probe), the in-circuit test enables very short test times (= high assembly throughput) combined with a very high test coverage.
-
Product
PXI Potentiometer Module 1x24 Bit, 0 Ohm to 16M Ohm
40-296-021-1/24
Programmable Resistor Module
The 40-295 is a Programmable Resistor module with up to 18 channels of 8-bit resolution resistor chains in a single 3U PXI module. The flexible architecture allows these modules to also be supplied as 12, 16 or 24-bit resolution versions for applications requiring finer resolution, greater resistance range or higher channel count.
-
Product
Dual 16x8 1-Pole High-Density PXI Matrix Module
40-520-205
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2A-2
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
PXI/PXIe High Density Precision Resistor Module, 9-Channel
40-297A-025
Programmable Resistor Module
The 40-297A-025 (PXI) and the 42-297A-025 (PXIe) are 9-channel programmable resistors with a range of 1.5 Ω to 13.6 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Non Replaceable General Purpose Probe
MEP-20
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Bench Meters
-
A classic style multimeter with True RMS and phase rotation. This manual ranger covers the electrical parameters you need for HVACR and, with detachable test leads, works with our accessory heads to test non-electrical parameters too. The LT16A meter measures current, resistance, voltage, capacitance, frequency, continuity and more. Test leads store in the meter body along with the tilt stand and magnetic hanger. The body is constructed of durable ABS plastic and a blue backlight makes the large LCD even more visible.
-
Product
Cryogenic Temperature Sensors
Interchangeable Rox™
-
Ruthenium oxide temperature sensors are thick-film resistors, with most models suitable for use in magnetic field applications. These composite sensors consist of bismuth ruthenate, ruthenium oxides, binders, and other compounds that allow them to obtain the necessary temperature and resistance characteristics. Each Lake Shore Rox™ model adheres to a single resistance versus temperature curve.
-
Product
Precision Resistor Module 18-Channel
40-297-001
Precision Resistor Module
A simple solution for applications requiring accurate simulation of resistive sensors. The 40-297 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. It is particularly well suited to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.
-
Product
Digital Multimeter
DMT-4010RMS
-
Monacor International GmbH & Co.
*True RMS measurement method*Dust and water protection according to IP class 67 with covered measuring sockets*Auto ranging for faster measurements*4000 digit resolution*Additional bar display*Voltage measurement up to DC/˜ 1000 V*Current measurement up to DC/˜ 10 A*Frequency measurement up to 10 MHz*Resistance measurement up to 40 MΩ*Capacitance measurement up to 40 mF*Temperature measurement -20 °C to +760 °C*Acoustic continuity test*diode test*Data hold (measured value memory)*peak hold*Maximum and minimum value recording*LC display with switchable background lighting*Automatic shutdown*overload protection*Supplied with test leads and protective case
-
Product
Alternate 3.00 (85.00) - 5.70 (162.00) General Purpose Probe
P2664G-1C2S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
5kV Insulation Resistance Tester
KV3122
-
KV Hipot Power Test Equipment Co.,Ltd
KV3122 Insulation Resistance Tester is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. Digital insulation resistance meter is composed of medium and large scale integrated circuits, including high-precision micro current measurement system, digital boost system and automatic discharge circuit.
-
Product
Battery Conductance Tester
SAT-AC
-
Shaanxi Aitelong Technology Co., Ltd
SAT-AC Battery Conductance Tester is a multi-function and portable digital data storage measurement instrument to test battery running condition and parameters quickly and precisely. It can display and record many key parameters for multi-groups like battery string and each battery cell’s voltage, conductance, connecting strip resistance, battery’s internal resistance and so on; offer the ability to distinguish battery’s condition effectively and accurately; compose with intelligent PC measurement analyzing software, user can track battery’s decay trend, and alarm beforehand to help technician and administrators process according to status.
-
Product
Handheld Economic Process Calibrator
VA701
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.
-
Product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25H79-12
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXI High Density Precision Resistor Module, 3-Channel, 4Ω to 5.82MΩ
40-298-152
Programmable Resistor Module
The 40-298-152 is a high density programmable resistor module with 3 channels which can be set between 4Ω and 5.82MΩ with 0.5Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
Product
PXI RTD Simulator Module 12 Channel PT100
40-262-201
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
Product
PCI Precision Resistor Card 18-Channel, 1Ω To 470Ω
50-297-014
Programmable Resistor Module
The 50-297 provides a simple solution for applications requiring accurate simulation of resistive sensors. The 50-297 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. It is particularly well suited to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1HF-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
High Voltage Inclined Plane And Erosion Tester
-
SCR ELEKTRONIKS have developed HIGH VOLTAGE INCLINED PLANE AND EROSION TESTER to carryout test specified in many standard to cover test method for the evaluation of the relative tracking and erosion resistance of insulating solid using liquid contaminant (ASTM D2303). Perform the Initial Tracking Voltage Test, Time to track Test, And Erosion Test as per selection.
-
Product
True RMS Digital Multimeter
72-10415.
-
*Handheld digital multimeter*Measure AC/DC voltage, AC/DC current, resistance, frequency and capacitance*Diode test and continuity buzzer*Manual function select & auto ranging*Data hold function*Auto power off, low battery indication*Input impedance for DC voltage around 10Mohm*MAX / MIN / Relative Modes*Analog Bar Graph*CAT III 1000V, CAT IV 600V rated