Resistance Meters
measure opposition to electrical current.
See Also: Resistance, Resistivity, Resistance Standards, Resistance Test, Resistivity Meters
-
Product
Resistance Meters
-
ACL provides surface resistance/resistivity meters and digital megohmmeters to quickly and accurately measure resistivity.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Transformer Winding Resistance Meters
TWA Standard Series
-
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Winding Resistance Meters
-
The NMC 'TDR' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. 'TDR' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. 'TDR' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.
-
Product
High Resistance Meters
-
Measurements International Ltd.
Direct or Substitution Measurements, Automatic and Manual Operation, No Temperature Coefficient, Multiple Modes of Operation.
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
Product
Circuit Breaker Contact Resistance Meters
-
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
Product
Winding Resistance Meter
TRM 104
-
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
Product
Surface Resistance Meter
990SRM
-
The Model 990SRM is a convenient, pocket-sized meter for measurement of surface resistivity and resistance to ground.
-
Product
Component Test Fixture For N1413 With B2980 Series
N1428A
Test Fixture
The N1428A is designed to operate specifically with the B2985B / 87B electrometer / high resistance meter. It is provided with two component modules, which are used to hold SMD, lead, and various types of devices. Electrical noise effects are reduced by the employment of a shielded case. A built-in interlock circuit enables safe high-voltage measurements. The N1413A high resistance meter fixture adapter is also required to connect the N1428A to the B2985B / 87B.
-
Product
Ohm-Stat Ground/Circuit Tester to Test ESD Ground
-
Tests ground for all 110v electrical circuitsWill determine the status of all electrical groundsEasy to use LED lightsWarranteeProduct conforms to the ESD S.20.20 spec standardsIdentify electrical problemsUsed with the Ohm-Stat RT-1000 resistivity meter
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Earth Resistance & Resistivity Meter
MRU-200
-
MRU-200 is the only meter in the market which uses all measurement methods.Possible measurements:- earth resistance measurment with 2-pole, 3-pole,4-pole method,- impulse earth resistance measurement, two kinds of measuring impulse 4/10s, 10/350s,- earth resistance measurement without disconnecting measured earths (using clamp),
-
Product
Winding Resistance Meter 50Amps, 3 Channels Rack
WR50-13R
-
Raytech Digital Winding Resistance meter WR50-13R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Femto / Picoammeter and Electrometer / High Resistance Meter
B2980A Series
-
Both the picoammeters and electrometers provide a world-best performance of 0.01 fA (0.01 x 10-15 A) current measurement resolution. In addition, the electrometers can measure resistance up to 10 P (10 x 1015 ), which is also a best-in-class specification. Finally, since AC power line noise can be difficult to eliminate when making low-level measurements, both the picoammeters and electrometers are available in battery powered versions.
-
Product
Precision Resistance Meter
IC4
-
Precision digital resistance meter IS4 is intended for use in an upgraded version of the TEST-9110 installation quality control system and testing on-board cable networks. The IC4 module can also be successfully used in other control and measurement systems based on the open international VXI standard.
-
Product
Earth Ground Resistance Meter
1623-2
-
The Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps.
-
Product
Oil Resistivity Test System / Million Meg Ohm Meter (MM1)
OTD-45
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Model : OTD-45OTD-45 is single self contained unit containing oil test cell, high frequency induction heating with temperature controller/sensor; dielectric loss measuring bridge, AC test voltage source, SF6 filled standard capacitor; high resistance meter; DC voltage source and all digital circuits.
-
Product
Insulation Resistance Meter
AMIC-10
-
The AMIC-10 digital insulation resistance meter is used for direct measurements of the insulation resistance of electrical equipment working with voltage up to 1 kV. In addition, this meter makes it possible to measure compensation and protective connections, low-voltage resistance measurements and DC and AC voltage measurements.
-
Product
Resistance Meter
MS8-2L
-
M-module MC8-2L is a mezzanine module designed to measure resistance using a two-wire measurement scheme in eight channels (eight-channel digitizer). М-module МС8-2Л is installed on the mezzanine carrier - NM module and is connected to it via a local information highway. Up to four m-modules of various types can be installed on the HM module. The NM module, together with the m-modules installed on it, forms a VXI module of size C-1 and is used to create information measuring VXI systems.
-
Product
Earth resistance meters
-
The PROMAX earth meters guarantee the proper operation of industrial and home electrical circuits.
-
Product
Dynamic Contact Resistance Meter
-
Dynamic contact resistance measurements are necessary to understand the condition of the arcing contacts of the circuit breaker. Static contact resistance measurements do not give us information related to erosion of arcing contact, misalignments of the contact, and damages to the driving mechanism.
-
Product
Resistance Meters
-
High-Speed High-Stable Resistance Meter with Low-impact Resistance Measurements for Miniature 008004-size Electronic Parts
-
Product
Resistivity Meter with Multi Electrode
POLARES
-
Till this moment the use of Electrical Resistivity Tomography (ERT) for geology has always been basically the same since its debut, based on the original vertical Electrical Soundings (VES) principles: applying a continuous current to two stakes inserted into the ground and measuring the corresponding voltage between other two. The applied current and thus the relative tension have always been continuous, with an inversion in polarity for each measure. The new tool POLARES uses an alternate current, instead, sinusoidal type, with an adjustable frequency.
-
Product
Resistivity Meter of Powder Composites
RM-200
-
The resistivity meter is fully automated and does not required any adjustments. The measurement is made by using the four-point contact probe on the ring (ø60 x ø50 x 5mm) and rectangular prisms samples (6 x 6 x 60÷80mm). The measurement results are automatically saved in meter memory, what allows user to manage of data. The RM-200 contain series connection which allow the data transmission to PC.
-
Product
Time, Current, And Resistance Meter
-
AllWin Instrument Science and Technology Co., Ltd.
1. Time, current and resistance can be displayed simultaneously2. Out put current:5~30A. Ground resistance range: 50~600 mohm