Showing results: 1291 - 1305 of 1715 items found.
-
40-190B-501 -
Pickering Interfaces Ltd.
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-201 -
Pickering Interfaces Ltd.
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-202 -
Pickering Interfaces Ltd.
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-401 -
Pickering Interfaces Ltd.
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-101 -
Pickering Interfaces Ltd.
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-001 -
Pickering Interfaces Ltd.
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-102 -
Pickering Interfaces Ltd.
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-301 -
Pickering Interfaces Ltd.
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
DSOS254A -
Keysight Technologies
2.5 GHz bandwidth (upgradable)4 analog channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.4 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15 inch capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
778033-01 -
NI
The PCI‑GPIB+ combines an IEEE 488 controller and an analyzer on one device for computers with PCI slots. You can use this device to integrate an instrument into your system using GPIB as well as to troubleshoot and solve GPIB hardware and software problems. The PCI‑GPIB+ achieves maximum IEEE 488.2 transfer rates. With an onboard bus master DMA controller, there is no microprocessor interruption in data transfers. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
780879-01 -
NI
The sbRIO‑9871 adds RS485/RS422 serial ports to CompactRIO systems. The serial ports are accessed directly from the FPGA to offer you flexibility in communicating with serial devices. The module has individual buffers on every port that save FPGA space and simplify programming. The sbRIO‑9870 supports standard start bit, stop bit, and handshaking settings. It uses an external power to provide maximum compatibility and reliability under all serial port conditions. Non-enclosed modules are designed for OEM applications.
-
780922-01 -
NI
The sbRIO‑9870 adds RS232 serial ports to CompactRIO systems. The serial ports are accessed directly from the FPGA to offer you flexibility in communicating with serial devices. The module has individual buffers on every port that save FPGA space and simplify programming. The sbRIO‑9870 supports standard start bit, stop bit, and handshaking settings. It uses an external power to provide maximum compatibility and reliability under all serial port conditions. Non-enclosed modules are designed for OEM applications.
-
FIM Series -
Axiomtek Co., Ltd.
Axiomtek's FIM (Flash in Module) series is designed into ATA protocol type with compatible IDE standard interface based on flash memory technology. This flash module is offered with various capacities ranging from 128MB up to 4GB and can operate under industrial temperature range goes from -40°C~85°C in the harsh operating environments. The features of reliability, high performance, cost-effective and easy-to-integrate designs make FIM series a perfect solution over traditional storage devices.
-
Giant-B15/B17/B19 -
ADLINK Technology Inc.
Giant Series panel PCs are designed with maximum reliability in mind. The fanless, 15, 17 and 19-inch Giant Series panel PCs offer fully enclosed, IP65 rated protection against water and dust. These rugged systems also feature optional solid state flash drives (SSD) instead of hard drives with rotating disks (HDD) for additional shock and vibration resistance, and their fanless design allows them to function reliably in a temperature range from 0°C to 40°C.
-
TE Connectivity Ltd.
TE Connectivity (TE) offers load cell assemblies for test and measurement applications that require high performance or unique packaging. Our broad range of packaged load cells feature foil strain gages enabling OEM's to measure force with low cost and high reliability. The gages produce a high level of output signal for a low operating stain using inorganic materials to offer long term stability. Load cells are gaged in a variety of materials from high strength stainless steel to special alloys.