Filter Results By:

Products

Applications

Manufacturers

RF

3 kHz to 300 GHz. AKA: Radio Frequency

See Also: Radio Frequency, Microwave, VHF, MW


Showing results: 3106 - 3120 of 3192 items found.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Current Switches

    B-1002 - ROSS ENGINEERING CORPORATION

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • Programmable Digital Attenuator

    LDA-602EH - Vaunix Technology Corporation

    The LDA-602EH has a large attenuation range of 120 dB with an exceptional 0.1 dB step size, allowing for both precision and accuracy during fading tests or device characterizations. This attenuator also features a fast 15 us switching speed, an operating temperature from -30oC to 50oC, a maximum RF input of +28 dBm, and is priced at $875. The LDA602-EH operates with a low insertion loss of 9 dB to 6 GHz, an input IP3 of +55 dBm and a typical VSWR of 1.3:1. Easily programmed for ATE applications, the LDA digital attenuators are a cost effective solution whether you are in engineering, the production test lab, or in the field. Units are ROHS compliant and can be used with any PC or laptop computer with USB 2.0 port (or powered USB hub) and Windows operating system. Lab Brick Signal Generators are provided with easy to use Lab Brick GUI software, 32 and 64 bit API DLL files, LabVIEW and Linux compatible drivers.

  • TestCentre

    ARC Technology Solutions

    ARC has experience with complex, commercially available test executives that are available for high volume production needs. Often times, when you don’t need the horsepower of a full featured executive, you are left with creating a specifically defined test program or crafting your own test sequencer. Rather than go down this path and spending your time on architecture, TestCentre brings a simple, yet elegant solution to this all-common problem. Used in many of ARC’s standard test stations, the robust, sequence based architecture of TestCentre, allows you to focus on the testing task at hand. While having some of the more advanced features found in high-end test executives, TestCentre, when mixed with RF analyzers and PXI based test solutions are a great, low cost solution to help solve your everyday testing requirements. Along with TestCentre and an ARC supplied rack-based test platform, your test challenges can be solved in doing circuit card testing, assembly/module level testing, or depot repair troubleshooting tasks.

  • Services

    Pure Engineering, llc

    At Pure Engineering, we specialize in providing custom solutions to help our clients overcome their most challenging problems. Our services range from rapid prototyping to mass production of consumer products and are backed by our deep understanding of low power design, RF complexities, design for manufacturing, and product life cycles. Our team is skilled in a variety of areas, including strategic planning, product development, and architecture design. We use engineering principles to assess the feasibility and suitability of technology for a given design and can create proof-of-concepts, prototypes, and subject matter experts to solve design challenges. We also have expertise in the Internet of Things (IoT) and have experience developing low-power systems that run on batteries and efficiently transfer data. Additionally, we have extensive experience in Bluetooth Low Energy (BLE) technology, creating sensors that connect to modern phones and computers and creating custom protocols using off-the-shelf hardware. Whether you need help with a specific aspect of your project or support throughout the development process, we are here to assist you.

  • 1207a Multi Channel Auto Switch

    Precise Time and Frequency, Inc.

    With intense competition and subscribers demanding ever more from service providers, quality and availability of service have never been more critical to maintaining and expanding your subscriber base.To complement our range of our high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new RF, Digital, and Time Code, Auto Switch / Distribution unit to insure you deliver the performance and reliability your customers demand.The ptf 1207A delivers up to eight channels of fully redundant, frequency and timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others, with NO SINGLE POINT OF FAILURE.The unit accepts two inputs on each channel from separate sources (primary and backup), monitors the inputs for signal integrity, and outputs the primary signal with no degradation of the input.If the primary input on any channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.The unit will accept up to eight channels simultaneously and independently switch on each channel.The unit also includes full remote monitoring and control via RS232 and Ethernet interfaces.

  • Noise Location Package

    Type HFDF - National RF, Inc

    National RF’s Type HFDF high frequency location system is a proven noise hunting and location directional antenna system that allows you, in many cases, to walk right up to the source of High Frequency (HF) noise! Used by several power companies around the United States, professional noise hunters, and other communications specialists, the HFDF has located noise sources that emanated from pole power transformers, arcing electric fences, CATV in-line amplifiers, plasma TV screens, and even Marijuana grower’s heating lamps! The system incorporates several plug-in, tunable magnetic loop sensors of a proprietary National RF design, that cover the frequency range between 1.8 MHz and 55 MHz. The unit is packaged in a hand-held, lightweight metallic enclosure, with a pistol grip and a magnetic compass mounted on top. The compass is used to get magnetic bearings to the noise source, which may be plotted on a map to triangulate, and ultimately pin-point, the location of the noise source. In certain cases, our customers tell us that they have been able to walk right up to the interfering noise source and correct the situation on the spot!

  • WIreless Controller

    Site Sentinel CXT - Teledyne Gas & Flame Detection

    ​Command functions include alarm reset, alarm acknowledge, alarm test and radio silence. In normal operation the control panel provides real time display of gas concentrations or the status of other field devices; battery charge levels, network RF signal quality and any number of fault diagnostic conditions affecting either an individual field device or the entire network. These fault conditions are displayed on the control screen.Options include audio alarm, visual alarm, external alarm port, alarm reset switch and up to 4 external wired sensor inputs. Standard features include a power-in port and power switch.The control panel is rated for Class 1, Division 2; Groups A, B, C, D hazardous areas. Operator interface is non-intrusive via magnetic contact switches located behind the glass lens cover. This advanced design takes advantage of a low power LCD with back light and ultra low power components. Power is provided by an internal rechargeable battery and/or 11.5 to 30VDC. Operating time is 1-2 months before recharge is required. An optional solar charging panel can be used to extend operating time for virtually any application.

  • HV Rotary Switches

    B-1003 - ROSS ENGINEERING CORPORATION

    A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use.  In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation.  G-7 silicone glass is used for special applications where RF or high temperatures are involved.  Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force.  This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions.  Ratings to 150kV, to 200A.  When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater.  In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional).  Each unit is either manually or electrically operated.  One SPDT contact is standard on most units.  The auxiliary contact is used as an interlock for protection against "Switching Hot".

  • 20 GHz Signal Source

    VCO Series - SignalCore, Inc.

    The SC5510A and SC5511A are VCO-based, synthesized signal sources with very low phase noise and an amplitude control of 0.01 dB throughout its -30 dBm to +15 dBm output power range. By utilizing a unique multiple phase-locked loop architecture, phase spurs are kept below -70 dBc across the entire tuning range, even at 1 Hz step resolution. Download the data sheet to see how the impressive features and specifications of these modules make them stand out when compared to other small modular synthesizers. These 20 GHz signal sources include an additional, independent RF2 channel with a tunable frequency range from 100 MHz to 3 GHz and a tuning resolution of 25 MHz. The extra channel makes the modules suitable for either single-stage RF conversion systems or dual-stage image suppression up/down converter systems. Both modules make great general-purpose laboratory signal sources where demanding low phase noise and signal purity are required. They are both ideal choices as an integrated clock source for fast DAC and ADC applications, especially those that require variable sampling rates. Full implementation instructions, GUI, driver software, and example code are provided with each module.

  • Custom Testing Solutions

    Enable Integration

    Test and MeasurementEnable increases the robustness of your test and measurement solutions, thereby reducing errors and associated costs. Data Acquisition (DAQ)Enable defines and builds custom DAQ systems for automated measurements of any process or manufactured part. Control and AutomationEngineeringEnable ensures that your processes are programmed to be safe, effective and optimized for both speed and quality. Real-Time and Mission CriticalSystemsEnable develops dependable real-time systems and Hardware in the Loop (HIL) simulations for high-speed applications. Motion ControlEnable creates software for synchronized multi-axis robotic control of velocity, position, force and action. Machine VisionEnable implements software and hardware-based solutions for precise image analysis, data extraction and vision-guided machine control. R&D Systems/Product DevelopmentEnable’s team of engineers and scientists works with you to address and solve problems containing technical challenges and uncertainties. Electronic Test SystemsEnable programs and builds software and hardware-based solutions for accurate measurements, from DC to RF. Mobile App DevelopmentEnable enhances your systems by integrating custom iOS and Android apps. Web DevelopmentEnable enhances your systems by integrating desktop and mobile web frameworks using PHP, CSS and HTML5. Database DevelopmentEnable decentralizes your data storage to be online, secure and accessible from anywhere.

  • Telemetry Transmitter for FM with up to 3 Bands

    LS-11-F - Lumistar Inc.

    The LS-11-F portable FM test transmitter is designed for checkout and troubleshooting of telemetry receiving systems operating with FM modulation. For applications with any of the ARTM modulations (Tier 0, Tier I, or Tier II), please refer to the LS-11-M Data Sheet. Complete ground stations including the antenna with LNA, RF down-converter, IF receiver, bit synchronizer, and PCM decommutator can be tested and bit error tests performed. The design allows secure links to be tested with an external encryptor. The Test Transmitter contains an internal PCM Data Simulator and Pseudorandom patterngenerator that operates in a BERT mode. The device provides simulated clock and data (without transmitter enabled) and accepts external data for modulating the internal transmitter. Complete setup can be achieved locally through the keypad and two-line LCD display or remotely through the USB Interface. Operational parameters include the PCM format parameter database information (frame sync patterns, wavewords, etc…), pre-modulation filter selection, transmitter carrier frequency, transmitter deviation, and output power level. Output power can be selected from approx. -60 to +5 dBm in 5 dB steps. The Test Transmitter contains a LiFePO4 Battery (Lithium Iron Phosphate), which provides higher energy density at ¼ the weight of legacy lead-acid batteries. The unit also provides an internal battery charger and will operate for up to twelve hours on battery power having received on a full charge.

  • EMC Test Equipment

    TDEMI Mobile+ series - Gauss Instruments

    The new benchmark for your fastest product pre-certifications on the planet. The new TDEMI Mobile+ (TDEMI M+) receiver series of GAUSS INSTRUMENTS is a very compact and robust designed instrument for optimum mobility and outdoor use as well as on developers workbench in your lab. It provides a vast variety of functionalities. The TDEMI M+ receiver series is equipped with a +12V supply - so it can be easily used for on-board testing, e. g. in vehicles or aircrafts and so on. By its integrated touch-sensitive and high resolution screen and the embedded PC the TDEMI M+ is a fully stand-alone instrument independent from any control or host or display unit e. g. as a PC or laptop. Thus it provides even more flexibility for your emission measurements. Furthermore the instrument can be powered by a battery pack (Option BAT-UG) making it even more flexible and easy to carry it around without any need of an external power supply. Especially designed for your todays challenging pre-certification tasks the TDEMI M+ provides the absolutely unrivaled advantages in speed and performance of the well known and market approved GAUSS INSTRUMENTS time-domain and RF technology. Thus, your pre-certification measurements and investigations can be performed up to 16000 times faster than by conventional receivers. The instruments of the TDEMI M+ receiver series are available for the frequency ranges up to 1 GHz, 3 GHz, 6 GHz or 7 GHz starting from 9 kHz each. Additionally these blazing fast measurements can be carried out even starting from 10 Hz optionally (Option MIL/DO-UG).

  • Portable CCD Spectroradiometer

    LMS-6000 - Lisun Electronics Inc.

    The Portable CCD Colorimeter Spectroradiometer has the following versions which can measure different parameters: • LMS-6000: illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000L: cd/m2, fL, Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000P: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio • LMS-6000S: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio, Rf and Rg according to TM-30 • LMS-6000F: LMS-6000 Parameters+Flicker test • LMS-6000B: LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 • LMS-6000BF: LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002

  • Generators

    Radio Pulse Signal Generator - ZETLAB Company

    The Software Signal generator allows to to produce radio pulse signals of various pulse rate and frequency at the DAC output.

Get Help