Filter Results By:

Products

Applications

Manufacturers

RF

3 kHz to 300 GHz. AKA: Radio Frequency

See Also: Radio Frequency, Microwave, VHF, MW


Showing results: 1141 - 1155 of 3195 items found.

  • RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port

    85091D - Keysight Technologies

    The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.

  • RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port

    85092D - Keysight Technologies

    The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.

  • RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port

    85094D - Keysight Technologies

    The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.

  • RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port

    85098D - Keysight Technologies

    The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.

  • Dual L-Band RF Tuner and 4-Channel 500 MHz A/D with Virtex-7 FPGA - 6U VPX

    Model 58791 - Pentek, Inc.

    - Accepts RF Signals from 925 MHz to 2175 MHz- Two programmable LNAs handle L-Band input signal levels from -50 dBm to +10 dBm- Programmable analog downconverter provides IF or I+Q baseband signals at frequencies up to 123 MHz- Four 500 MHz 12-bit A/Ds digitize IF or I+Q signals synchronously; optional: 400 MHz 14-bit A/Ds- Four FPGA-based multiband digital downconverters- Xilinx Virtex-7 VX330T or VX690T FPGAs- 8 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 & 3) interface, up to x8- Clock/sync bus for multimodule synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • L-Band RF Tuner and 2-Channel 400 MHz A/D with Kintex UltraScale FPGA - 6U VPX

    Model 57891 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Accepts RF signals from 925 MHz to 2175 MHz- Programmable LNA handles L-Band input signal levels from -50 dBm to + 10 dBm- Programmable analog downconverter provides IF or I+Q baseband signals at frequencies up to 123 MHz- Two 400 MHz 12-bit A/Ds digitize IF or I+Q signals synchronously- Two FPGA-based multiband DDCs (digital downconverters)- Xilinx® Kintex® UltraScale™ FPGA- Five GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- PCI Express interface (Gen. 1, 2 & 3) up to x8- Clock/sync bus for multimodule synchronization- Optional LVDS and gigabit serial connections for FPGA for custom I/O- Navigator BSP® for software development- Navigator FDK® for custom IP development- Spark® fully-integrated development system- Free lifetime applications support- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • L-Band RF Tuner and 2-Channel 400 MHz A/D with Kintex UltraScale FPGA - 3U VPX

    Model 54891 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Accepts RF signals from 925 MHz to 2175 MHz- Programmable LNA handles L-Band input signal levels from -50 dBm to + 10 dBm- Programmable analog downconverter provides IF or I+Q baseband signals at frequencies up to 123 MHz- Two 400 MHz 12-bit A/Ds digitize IF or I+Q signals synchronously- Two FPGA-based multiband DDCs (digital downconverters)- Xilinx® Kintex® UltraScale™ FPGA- Five GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- PCI Express interface (Gen. 1, 2 & 3) up to x8- Clock/sync bus for multimodule synchronization- Optional LVDS and gigabit serial connections for FPGA for custom I/O- Optional optical interface for data streaming- Navigator BSP® for software development- Navigator FDK® for custom IP development- Spark® fully-integrated development system- Free lifetime applications support- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • Dual-Band RF Tuner and 4-Ch 400 MHz A/D with Kintex UltraScale FPGA - 6U VPX

    Model 58891 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Accepts RF signals from 925 MHz to 2175 MHz- Programmable LNA handles L-Band input signal levels from -50 dBm to + 10 dBm- Programmable analog downconverter provides IF or I+Q baseband signals at frequencies up to 123 MHz- Four 400 MHz 12-bit A/Ds digitize IF or I+Q signals synchronously- Four FPGA-based multiband DDCs (digital downconverters)- Two Xilinx® Kintex® UltraScale™ FPGA- 10 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- PCI Express interface (Gen. 1, 2 & 3) up to x8- Clock/sync bus for multimodule synchronization- Optional LVDS and gigabit serial connections for FPGA for custom I/O- Navigator BSP® for software development- Navigator FDK® for custom IP development- Spark® fully-integrated development system- Free lifetime applications support- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • Large Size RF Test Enclosure, ≥100 DB Isolation, 300 MHz - 18 GHz

    dbSAFE MAX - DVTest Inc.

    Some applications require larger test environments. The dbSAFE MAX blends all the superior isolation characteristics of the standard dbSAFE DUO shielded box into a larger volume to guarantee you get better results.

  • Power Divider Combiner, 2 Way, SMA RF Splitter for Distributed Antenna Systems (DAS)

    PD2120 - INSTOCK Wireless Components, Inc

    Ideal for DAS (698 - 2700 MHz)Low Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)RoHS Compliant Splitter ConstructionTri Alloy SMA Female (Jack) 50 Ohm

  • 2x (1 to 8) +1X (2 to 1) 50 Ohm 2.5GHz RF Multiplexer Terminated

    YAV92501 - 6TL Engineering

    2x (1×8) Mux + 1×2 + 2x Pass trough 30Vac/dc, 10W Max Max current 500mA Control port CAN o Ethernet (con Ethernet to CAN Gateway) Dissipative

  • PXI-2596, 26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module

    778572-96 - NI

    26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2596 is an RF signal multiplexer switch with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use the PXI‑2596 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PXI-2796, 40 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module

    782356-01 - NI

    40 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2796 offers a high-density, unterminated multiplexer with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.

  • PXI-2797, 40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module

    782357-01 - NI

    40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2797 offers a high-density, terminated multiplexer with dual 6x1 multiplexer banks in the same module. The internal termination of the PXI‑2797 helps prevent high-power reflections that arise from open channels on the module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.

  • PXI-2597, 26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module

    778572-97 - NI

    26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

Get Help