Filter Results By:

Products

Applications

Manufacturers

Memory

data retained.

See Also: Memory Test, DDR, NAND, DRAM, Memory Device


Showing recent results 76 - 90 of 1566 products found.

  • PCI Express Waveform Digitizer: 14-Bit A/D, 125 MS/s, 8-CH, 100 MHz BW, 4-16 GB Memory

    Octopus Express 14 CompuScope - PCIe - GaGe

    8-CH model featuring 20 software selectable A/D sampling rates from minimum 1 kS/s to maximum 125 MS/s per channel with input bandwidth of 100 MHz. ADC data can be captured in octal, quad, dual, or single channel modes. Full-featured front-end with software selectable DC/AC coupling and 50Ω / 1MΩ inputs. Ease of integration with External or Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PCIe Gen2 x8 data streaming rates at 2 GB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PCI Express Waveform Digitizer: 14-Bit A/D, 400 MS/s, 2-CH, 200-400 MHz BW, 512 MB Memory

    PX14400A - PCIe - Signatec

    2-CH AC-coupled model with a frequency synthesized clock that allows the ADC sampling rate to be set to virtually any value from 20 MHz to 400 MHz, offering maximum flexibility for sampling rate selection. ADC data can be captured in dual or single channel modes. Hardware configurable options include a programmable gain amplifier front end with 200 MHz input bandwidth or direct transformer front end with 400 MHz input bandwidth. PCIe x8 data streaming rates at 1.4 GB/s. Programming-free operation with Scope oscilloscope software. Software Development Kits available for C++ for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PCI Express Waveform Digitizer: 16-Bit A/D, 25 MS/s, 4-CH, 20 MHz BW, 4-16 GB Memory

    Octave Express 16 CompuScope - PCIe - GaGe

    Available in 4-CH and 2-CH models featuring 15 software selectable A/D sampling rates from minimum 1 kS/s to maximum 25 MS/s per channel with input bandwidth of 20 MHz. ADC data can be captured in quad, dual, or single channel modes. Full-featured front-end with software selectable DC/AC coupling and 50Ω / 1MΩ inputs. Ease of integration with Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PCIe Gen2 x8 data streaming rates at 200 MB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PCI Express Waveform Digitizer: 8-Bit A/D, 1.5-3 GS/s, 2-CH, 2 GHz BW, 1 GB Memory

    PX1500-2 - PCIe - Signatec

    2-CH model with a frequency synthesized clock that allows the ADC sampling rate to be set to virtually any value from 200 MHz to 1.5 GHz, offering maximum flexibility for sampling rate selection. Using interleaving mode, 1-CH can sample up to 3 GS/s. ADC data can be captured in dual or single channel modes. Hardware configurable options include an amplifier front end for 1 GHz input bandwidth or transformer front end for 2 GHz input bandwidth. PCIe x8 data streaming rates at 1.4 GB/s. Programming-free operation with Scope oscilloscope software. Software Development Kits available for C++ for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PCI Express Waveform Digitizer: 14-Bit A/D, 125 MS/s, 4-CH, 100 MHz BW, 4-16 GB Memory

    Octave Express 14 CompuScope - PCIe - GaGe

    Available in 4-CH and 2-CH models featuring 20 software selectable A/D sampling rates from minimum 1 kS/s to maximum 125 MS/s per channel with input bandwidth of 100 MHz. ADC data can be captured in quad, dual, or single channel modes. Full-featured front-end with software selectable DC/AC coupling and 50Ω / 1MΩ inputs. Ease of integration with External or Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PCIe Gen2 x8 data streaming rates at 1 GB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PCI Express Waveform Digitizer: 12-Bit A/D, 200 MS/s, 4-CH, 125 MHz BW, 8-16 GB Memory

    Razor Express 12 CompuScope - PCIe - GaGe

    Available in 4-CH and 2-CH models featuring 17 software selectable A/D sampling rates from minimum 1 kS/s to maximum 200 MS/s per channel with input bandwidth of 125 MHz. ADC data can be captured in quad, dual, or single channel modes. Full-featured front-end with software selectable DC/AC coupling and 50Ω / 1MΩ inputs. Ease of integration with External or Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PCIe Gen2 x8 data streaming rates at 1.6 GB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PXI Express Waveform Digitizer: 16-Bit A/D, 1 GS/s, 4-CH, 700 MHz BW, 8 GB Memory

    RazorMax Express CompuScope - PXIe - GaGe

    Available in 4-CH and 2-CH models featuring 31 software selectable A/D sampling rates from minimum 1 kS/s to maximum 1 GS/s per channel with input bandwidth of 700 MHz. ADC data can be captured in quad, dual, or single channel modes. Full-featured front-end with DC coupling (AC optional) and 50Ω inputs. Ease of integration with External or Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PXIe Gen3 x8 data streaming rates at 4+ GB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Optical Coherence Tomography (OCT), Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PCI Express Arbitrary Waveform Generator: 14-Bit D/A, 1.2 GS/s, 4-CH, 590 MHz BW, 1 GB Memory

    PXDAC4800 - PCIe - Signatec

    The PXDAC4800 is an exceptionally high-speed 4-CH PCIe DAC card that can be used as an Arbitrary Waveform Generator (AWG), a waveform playback device, or for generating multiple communication frequency bands. The PXDAC4800 features 14-bit DAC output at up to 1.2 GS/s for 2-CHs or up to 600 MS/s for 4-CHs, and 8-bit DAC output at up to 1.2 GS/s for 4-CHs. Each output signal has a bandwidth of up to 400 MHz for AC-coupled configuration or up to 590 MHz for DC-coupled configuration. Output waveforms may be "per-trigger" or "continuously looped" from the onboard 1 GB memory. The DACs can be provided with a continuous data stream via the PCIe interface with a sustained data rate at up to 900 MB/s that allows for providing up to 112.5 MS/s addressable bandwidth at full 14-bit resolution for each of the four analog outputs. Playback Application Software provides ability to playback signal data that is loaded in RAM, playback previously recorded signal data files, and generate signal data patterns for each output including sine wave, square wave, triangle wave, sawtooth wave, and zeroes. Software Development Kits (SDKs) for C/C++, LabVIEW and MATLAB are included for custom application development.

  • Qseven V1.2 SoM With I.MX287 454 MHz (Industrial) SoC, 128MB Memory, 4GB EMMC, Gigabit Ethernet, Audio And CAN

    Q7M100 - Axiomtek Co., Ltd.

    *Ultra low power consumption ARM9*High flexibility Qseven v1.2 compliant design*2 CANBus 2.0B compliant ports*24-bit TTL LCD*Dual 10/100 Base-T Ethernet*Audio

  • PCI Express Waveform Digitizer: 12-Bit A/D, 3-6 GS/s, 1-2-CH, 1.75 GHz BW, 4-8 GB Memory

    EON Express CompuScope - PCIe - GaGe

    Available in 2-CH and 1-CH models featuring 27 software selectable A/D sampling rates from minimum 1 kS/s to maximum 6 GS/s per channel with input bandwidth of 1.75 GHz. ADC data can be captured in dual, or single channel modes. Full-featured front-end with DC coupling (AC optional) and 50Ω inputs. Ease of integration with External or Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PCIe Gen3 x8 data streaming rates at 4+ GB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Optical Coherence Tomography (OCT), Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • PCI Express Waveform Digitizer: 8-Bit A/D, 2-4 GS/s, 1-2-CH, 1.5 GHz BW, 2-16 GB Memory

    CobraMax Express CompuScope - GaGe

    Available in 2-CH and 1-CH models featuring 19 software selectable A/D sampling rates from minimum 5 kS/s to maximum 2 GS/s or 4 GS/s for single channel with input bandwidth of 1.5 GHz. ADC data can be captured in dual or single channel modes. Full-featured front-end with software selectable DC/AC coupling and 50Ω inputs. Ease of integration with Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PCIe Gen2 x8 data streaming rates at 2 GB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • Qseven V2.0 SoM Evaluation Kit With Quad/DualLite 800 MHz (Industrial) SoC, 1GB Memory, 4GB EMMC, Gigabit Ethernet, Audio And CAN

    Q7M120-120-EVK - Axiomtek Co., Ltd.

    *Ultra low power consumption Cortex™-A9*High flexibility Qseven v2.0 compliant design*2 CAN 2.0B*18/24-bit TTL LCD*LVDS/HDMI 1080P*10/100/1000 Mbps Ethernet*Linux3.0.35/Android4.3*Audio

  • PCI Express Waveform Digitizer: 8-Bit A/D, 500 MS/s - 2 GS/s, 1-2-CH, 500 MHz BW, 2-16 GB Memory

    Cobra Express CompuScope - PCIe - GaGe

    2-CH models featuring 20 software selectable A/D sampling rates from minimum 2 kS/s to maximum 1 GS/s or 2 GS/s for single channel with input bandwidth of 500 MHz. ADC data can be captured in dual or single channel modes. Full-featured front-end with software selectable DC/AC coupling and 50Ω inputs. Ease of integration with External or Reference Clock In & Clock Out. External Trigger In & Trigger Out with advanced triggering operations. PCIe Gen2 x8 data streaming rates at 2 GB/s. Programming-free operation with GaGeScope PC oscilloscope software. Software Development Kits available for C/C#, LabVIEW and MATLAB for custom application development. Ideal for applications such as Automatic Test Equipment (ATE), Wideband RF Signal Analysis & Recording, RADAR, Electronic Warfare (EW), Ultrasonic Non-Destructive Testing (NDT), LIDAR, Communications, Optical Coherence Tomography (OCT), Spectroscopy, High-Performance Imaging, Time of Flight (TOF), Life Sciences, Particle Physics, and more.

  • COM Express Basic Size Type 6 Module with 4th Generation Intel Core i7/i5/i3 Processor with ECC memory (formerly codename: Haswell)

    Express-HLE - ADLINK Technology Inc.

    The Express-HLE is a COM Express COM.0 R2.1 Type 6 module supporting the 64-bit 4th Generation Intel Core i7/i5/3 processor with CPU (formerly codenamed Haswell), memory controller, and graphics processor on the same chip. Based on the latest Mobile Intel QM87 Express chipset, the Express-HLE is specifically designed for customers who need high-level processing and graphics performance in a long product life solution.

  • Qseven V1.2 SoM Evaluation Kit With I.MX287 454 MHz (Industrial) SoC, 128MB Memory, 4GB EMMC, Gigabit Ethernet, Audio, CAN And BSP

    Q7M100-100-EVK - Axiomtek Co., Ltd.

    *Ultra low power consumption ARM9*High flexibility Qseven v1.2 compliant design*5 UART*2 CAN*24-bit TTL LCD*10/100 Mbps Ethernet*Linux 2.6.35