Filter Results By:

Products

Applications

Manufacturers

Showing results: 1576 - 1590 of 1725 items found.

  • Parallel Electrode SMD Test Fixture, DC To 3 GHz

    16196A - Keysight Technologies

    The 16196A surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.

  • Keysight 20-Channel 5A Form A Switch for 34980A

    34938A - Keysight Technologies

    The Keysight 34938A is a high power general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 20 independent single-pole, single-throw (SPST) 5A relays. This module is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. Its 30VDC/250VAC, 5A contacts can handle up to 150W on a single channel, enough for many power line switching applications. Standard 50-pin Dsub connectors allow for use with standard cables, terminal blocks, or mass interconnect solutions.

  • Ethernet To Parallel Digital Interface Boards

    ICS Electronics

    ICS's Ethernet Parallel Digital Interface boards provide the user with a wide range of IO signals that can be user configured to match virtually any application. These Ethernet boards are available with high power relay driver boards and with optional firmware designed to simplify switching applications. The 80x3 boards have high-power TTL signals that can sink 48 mA and source 24 mA. Pullup resistors make it easy to interface with CMOS logic and to sense contact closures. User configures data byte direction and polarity. The 80x3 boards are VXI-11 compliant for operation with NI or Agilent VISA, LabVIEW and VEE and support raw socket connections. The new 8113 board is a CMOS close of the 8013 board with user set 3.3 or 5 V logic levels. Pinouts and command set is the same as the 8013 board. The 8113 communicates with TCP/IP(Raw Socket) protocoland and also has a RS-232 Serrial Port. All boards are designed for mounting against the rear panel or inside a chassis and use our Ethernet Wiring Kit for easy connection to a Ethernet Connector on the rear panel.

  • Smoke Detection Sensor – 120VAC Wire-In with Battery Backup

    ENVIROMUX-SDS-120V - Network Technologies Inc

    For warning of smoke and invisible fire particles. Ionization smoke detector. Applications from 40°F to 100°F (4°C to 38°C). Front loading battery door. 9V battery backup (included) in case of power failure. One button design for easy testing and HUSH mode activation control. LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode. Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours. Voltage supply: 120VAC. Pre-stripped wiring harness with tinned strands. Audio alarm: 85dB at 10ft. Dimensions: 5" diameter x 1.75" depth. Dust cover prevents false alarms. Tamper resist feature. Links with up to 24 devices. Max distance between first and last device: 1000ft (305m). Alarm memory indicates initiating alarm in interconnected systems. Use compatible relay (ENVIROMUX-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting. ENVIROMUX-RLY-SDS120V includes normally open and normally closed contacts. Contact ratings: 10A at 120VAC, 5A at 30VDC. Regulatory approvals: UL.

  • High Temperature Axial Torsional Extensometers (1200 C or 1600 C)

    Model 7650 - Jinan Testing Equipment IE Corporation

    Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.

  • UNI-T Series

    Weshine Electric Manufacturing Co., Ltd

    mainly used to measure the wire resistance of cables, the contact resistance ofswitches, connectors, relays, the resistance of coils, motors, transformer windings, and equipment enclosures, lightning protection belts, ground beams, structures, cabinets, steel bars, Test the connection resistance between metal components of water pipes, windows, guardrails, radiators, assembly lines, etc. It is widely used in telecommunications, electric power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc.

  • PXI Single 32x8 Matrix, 1 Pole Switching

    40-531-021 - Pickering Interfaces Ltd.

    Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Dual 16 x 8 Matrix 1 Pole Screened

    40-532-021-S - Pickering Interfaces Ltd.

    This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Single 32x8 Matrix, 1 Pole Screened

    40-531-021-S - Pickering Interfaces Ltd.

    Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Dual 16x8 Matrix, 1 Pole Switching

    40-532-021 - Pickering Interfaces Ltd.

    This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • Detector And FPA Testing

    Santa Barbara Infrared, Inc.

    The FPA Test Set (FPATS) interface to the detectors under test (DUT’s) is via a custom pedestal plate which provides both a conductive heat path to both the individual DUT’s as well as the field of view limiting aperture plate. This custom pedestal plate protrudes through the customer provided DUT interface printed circuit board (PCB) and makes physical contact with the rear of the DUT packages and the aperture plate when the FPATS is in the closed position. The pedestal plate is mounted to the ambient source plate and its temperature is actively driven by this subsystem.

  • LXI Low Thermal EMF Matrix 1-pole 56x33

    60-510-001 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • LXI Low Thermal EMF Matrix 1-pole 44x33

    60-510-021 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • LXI Low Thermal EMF Matrix 1-pole 28x33

    60-510-003 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • Multi-Zone Gas Monitor

    HGM-MZ - IMR Environmental Equipment, Inc.

    The Multi-Zone Monitor provides continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions.

Get Help