Aero Nav Laboratories, Inc.
The electrical contact testing is performed to determine the reliability of equipment under various contacting conditions. A few types of electrical contact tests are: contact-chatter monitoring, contact resistance, intermediate, and low level contact switching.
-
Weshine Electric Manufacturing Co., Ltd
The loop resistance tester is used to test the conductive loop resistance of various switchgear, and the test current shall not be less than 100A. Due to the oxidation of the contact surface, poor contact tightening and other reasons, the contact resistance increases. When a large current flows, the temperature of the contact point increases, which further accelerates the oxidation of the contact surface and further increases the contact resistance.
-
Harwin Plc
ATE Probes, Pogo pins and Contact Pads. Gold-plated, spring-loaded, capable of thousands of cycles. Probes for Automated Test Equipment (ATE). Various height SMT contact pins. Flat SMT contact pads. Spring loaded contacts consist of a plunger (or head), barrel (or body), and a fully encapsulated fine spring, to provide the spring force required to maintain positive contact. All have a high durability, exceeding 10,000 mating cycles.
-
WIKA Alexander Wiegand SE & Co. KG
Wherever the process pressure has to be indicated locally and, at the same time, limit values must be monitored, contact pressure gauges find their application. The switch contacts make or break circuits dependent upon the pointer position of the indicating measuring instrument. If the reading is significantly above or below a set value, they trigger an alarm, hence also the term “alarm contact”. Contact pressure gauges are also suitable for starting, stopping or switching processes.
-
-
-
-
VLT3673-G6 -
Van Leeuwen Test Systems BV
The VLT 3673-G6 suspension / road contact testers operate according to the well-known EUSAMA principle. However, the diagnostic options are not restricted to the contents of this specification. In addition to the usual road contact values, the following values are also measured and displayed: the contact value difference, resonance frequency and wheel weight at minimum contact value, tyre rigidity, wheel weight and axle weight. There is a general final evaluation so that all these values do not have to be interpreted after every test.
-
-
610138117 -
Virginia Panel Corporation
Available in twin-female, crimp/solder, twin male, and wire-wrap design, QuadraPaddle contacts are engineered for flexible interconnect options. Rated at 5 amps continuous (1250 VAC) with a 2 ounce insertion force, QuadraPaddle contacts provide 4 reliable points of contact per pin, outstanding electrical performance, and low mating force.
-
Omega Engineering, Inc
Contact level devices come in contact with the tank media and are used for point or cocntinious level measurement. Types include Float, Optical, RF Capacitence, Conductivity, Ultrasonic, Tuning Fork.
-
Virginia Panel Corporation
VPC offers a range of pneumatic contacts that are ideal for use with automatic engagement interface systems. These pneumatic contacts also work well when used together with the VPC iDock Series.
-
WIKA Alexander Wiegand SE & Co. KG
Wherever the process temperature has to be indicated locally and, at the same time, limit values must be monitored, thermometers with switch contacts find their application. The switch contacts make or break the circuit dependent upon the pointer position of the indicating measuring instrument. If the reading is significantly above or below a set value, they trigger an alarm, hence also the term “alarm contact”. The instruments are also suitable for starting, stopping or switching processes.
-
The Motwane Manufacturing Company
High contact resistance values are a definite cause of the failure or less than optimal performance in a wide variety of electrical devices. Contact resistance testing is therefore most critical to measure the resistance of electrical connections in switching devices, circuit breakers, isolators, busbars, relays, joints, connectors, cables, and cable joints. The device helps to find destructive or corroded contacts and hence protects substation devices from damage.
-
Virginia Panel Corporation
VPC twinaxial contacts provide differential voltage options most commonly used in digital and data applications.For increased reliability and to eliminate the need for polarization, the design of VPC's twinaxial contact consists of two concentric inner conductors for termination to the twisted pair, and an outer shield for termination of the cable shield.