Showing results: 451 - 465 of 843 items found.
-
40-837-001 -
Pickering Interfaces Ltd.
The 40-837-001 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-101 -
Pickering Interfaces Ltd.
The 40-837-101 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-002 -
Pickering Interfaces Ltd.
The 40-837-002 is a 75Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-102 -
Pickering Interfaces Ltd.
The 40-837 is a 75 2x2 RF matrix available with 1 or 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
AMC080/080C -
Vadatech Inc
The AMC080 is high density versatile I/O module. The 15 banks of 8-bit I/O can be used as input and or/output and are configurable to run as +3.3V or +5V. The unit interfaces to the system via GbE and/or PCI/10GbE. The I/O’s are accessible via HDC. It also has 8 bi-color LED’s on the front panel for indication and status. All LED’s are reconfigurable.
-
42-870A-006 -
Pickering Interfaces Ltd.
The 40-870A-006 (PXI) and 42-870A-006 (PXIe) are 50Ω RF switches with 6 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
42-870A-106 -
Pickering Interfaces Ltd.
The 40-870A-106 (PXI) and 42-870A-106 (PXIe) are 50Ω RF switches with 6 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
Seward Medical
A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.
-
TE0841 -
Sundance Multiprocessor Technology Ltd.
The Trenz Electronic TE0841 is an industrial-grade FPGA module integrating a Xilinx Kintex UltraScale KU35 or KU40 with 2x banks of 16-Bit width 512Mbtyes DDR4 SDRAM, max 256 MByte Flash memory for configuration and operation, and powerful switch-mode power supplies for all on-board voltages. A large number of configurable I/O’s is provided via rugged high-speed stacking connections.
-
Elmeasure India Pvt. Ltd
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
41-670-101-AABBCC -
Pickering Interfaces Ltd.
The 41/43-670-101 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
41-670-103-AABBCC -
Pickering Interfaces Ltd.
The 41/43-670-103 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
LMC-20 -
Eddy Co.
The LMC-20 functions not only as a light monitor for coating thickness, but also allows control of multi layer/multi material coating processes. Up to 2000 individual layers in a coating are possible, by using 40 program banks of 50 layers each. The characteristics of up to 99 different coating materials can be input as well. Final thickness can be calculated to 1% of a quarter wave.
-
40-876A-004 -
Pickering Interfaces Ltd.
The 40-876A-004 (PXI) and 42-876A-004 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-876A-104 -
Pickering Interfaces Ltd.
The 40-876A-104 (PXI) and 42-876A-104 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.