Showing results: 466 - 480 of 843 items found.
-
42-876A-104 -
Pickering Interfaces Ltd.
The 40-876A-104 (PXI) and 42-876A-104 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-004 -
Pickering Interfaces Ltd.
The 40-876A-004 (PXI) and 42-876A-004 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-002 -
Pickering Interfaces Ltd.
The 40-876A-002 (PXI) and 42-876A-002 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-102 -
Pickering Interfaces Ltd.
The 40-876A-102 (PXI) and 42-876A-102 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-876A-102 -
Pickering Interfaces Ltd.
The 40-876A-102 (PXI) and 42-876A-102 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-001 -
Pickering Interfaces Ltd.
The 40-876A-001 (PXI) and 42-876A-001 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-876A-101 -
Pickering Interfaces Ltd.
The 40-876A-101 (PXI) and 42-876A-101 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-876A-101 -
Pickering Interfaces Ltd.
The 40-876A-101 (PXI) and 42-876A-101 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-837A-002 -
Pickering Interfaces Ltd.
The 40-837A-002 (PXI) and 42-837A-002 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
40-837A-102 -
Pickering Interfaces Ltd.
The 40-837A-102 (PXI) and 42-837A-102 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-102 -
Pickering Interfaces Ltd.
The 40-837A-102 (PXI) and 42-837A-102 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-002 -
Pickering Interfaces Ltd.
The 40-837A-002 (PXI) and 42-837A-002 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
778966-01 -
NI
The PCI-6511 is an industrial digital input interface, with eight banks of isolated channels. If a computer or application fault occurs, the PCI-6511 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
779081-01 -
NI
The PCI-6510 is an industrial digital input interface, with a single bank of isolated channels. If a computer or application fault occurs, the PCI-6510 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
PA72DIOS6016 -
APPLICOS
The PA72DIOS6016 is a multifunctional digital design core. The FPGA allows for implementing many different custom applications. The connector has 64 Input/Output pins which can be assigned as TTL I/O or as differential inputs. 128 MByte of DDR2 memory is available to the FPGA, and an onboard EEPROM allows for storing values in non-volatile memory. The I/O bank voltage can be FPGA-selected between 2.5 and 3.3 Volt.