SBS Storage Battery Systems, LLC
The SBS constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests. These units are quick and easy to set up. They display the voltage, current and Ah removed during the test. Since this is a constant current load bank, the user also does not have to constantly adjust the current during the test like many other load banks.
-
K-1000 Rack Mounted -
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
Mosebach Manufacturing Company
Mosebach Pad Mounted Load bank is designed to be permanently mounted next to a generator for dedicated testing. Its unique design allows it to be one of the smallest on the market! This size enclosure will fit 50 kW, 75 kW or 100kW of testing ability. Also available in 300kW and larger load banks.
-
RL -
Junxy Energy
Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit. JUNXY has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.
-
K-1000 Resistive & Inductive -
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
RCD -
Junxy Energy
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
Mosebach Manufacturing Company
Mosebach’s XR series load bank offers you a range of options for resistive reactive loads in both lower voltages of 480 and 600 or MV at 4160 and higher. Outdoor rated user friendly for years of use.
-
BTS4000 -
Shenzen Neware Electronic Co LTD
Battery testing system for power banks(BTS-4000-6V4A-CCDC-USB) is based on Neware BTS4000, it shares all the main feature of BTS4000, such as 0.05%FS accuracy, 10Hz data acquisition frequency, based on Ethernet communication, etc.
-
Eagle Eye Power Solutions
The LB-Series AC Load Banks are designed for high power portable load testing of generators, UPS, and other critical AC power sources. Available models meet a range of voltages including but not limited to 208, 380, 440, and 480 VAC. Load power model options reach 1000 kW standard with other options available.
-
RLC -
Junxy Energy
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
SLB-Series -
Eagle Eye Power Solutions
SMART Constant Current DC Load Banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other testing for DC power with load. The SMART technology allows a constant current discharge without the need for manual adjustment of current during the discharge test. Our SLB-Series load banks are portable, durable, economic, safe, easy-to-use and come complete with our DataView software, providing the user with a complete data management and analysis program.
-
40-617-021 -
Pickering Interfaces Ltd.
The 40-617 18-Bank, 3-Channel, 1-Pole Multiplexer Module forms part of the System 40 PXI Programmable Switching system. The Module consists of 18 electrically isolated banks of multiplexers controlled by a PXI/PCI interface. Each bank is a 1 to 3 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously. Inter-bank linking relays allow multiplexer size to be increased in multiples of 3 by joining the common terminals of adjacent banks. Closing one linking switch produces a 6 channel multiplexer, closing all linking switches produces an 54 channel multiplexer.
-
40-616-021-16/5/1 -
Pickering Interfaces Ltd.
The 40-616 16-Bank, 5-Channel, 1-Pole Multiplexer Module forms part of the System 40 PXI Programmable Switching system. The Module consists of 16 electrically isolated banks of multiplexers controlled by a PXI/ PCI interface. Each bank is a 1 to 5 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously. The module is suitable for cascading in applications that require large multiplexer systems, it is also suitable for test systems that require the switching of a large number of signals in parallel.
-
40-659-102 -
Pickering Interfaces Ltd.
Model 40-659 is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC.The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.