Electra -
Simplex Inc
The Electra provides 460KW, 560KW or 660 of resistive load at both 240V and 480V, 3-phase. It can be applied at any AC voltage to 480V AC, 50-60-400 Hertz, single or 3-phase. Load step resolution is 5KW.
-
Atlas-Megawatt -
Simplex Inc
The Atlas-Megawatt provides 1000KW of resistive load at both 240V and 480V, 3-phase. It can be applied at any AC voltage to 480VAC, 50-60-400 Hertz, single or 3-phase. Load step resolution is 5KW.
-
LBP-350 -
Miller Electric Mfg Co.
Designed to provide an adjustable load for troubleshooting or demonstrating welding power sources or generators. Includes analog meters for AC and DC output with jacks for external metering connections.13 ft 115V power cord. Seven 50 amp load switch.
-
X250S Series -
Mosebach Manufacturing Company
The X250S is the only one of its kind: 250 kW in a very small package. Light, portable; with digital meter and recording capability. Center lifting bar and casters are both available as options. Ideal for "Black Tests" in data centers as blowers are powered externally with 120VAC
-
DSR-WB series -
MF Power Resistor Ltd
Power can be up to 20kW, depends on the resistance value and application- Support High Current up to 80A.- For some cases, can support 3 phase Rheostat application
-
FLT-1 WB -
Matrix Test Equipment Incorporated
The Model FLT-1-WB is our Wide Bandpass filters for measuringthe Video Carrier and the Composite Second Order Beatdistortion on both sides of the carrier.
-
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
BSC Filters
BSC have independently developed a fully reconfigurable adaptive filter solution, designed for fast & seamless switching into any of 256 filter states across the 2-18 GHz range. Ideally suited to EW front-end preselection or protection, any combination of bandpass and bandstop states can be selected INTRODUCTION. Each 2 GHz channel can be switched in (bandpass) and out (bandstop) of the signal path with a switching time of less than 100 ns. DC power and 8-bit TTL control is supplied through a standard 15-pin MDM connector. In the crowded spectrum of the future, front-end flexibility is of increasing importance. Not limited to 2-18 GHz or equal channel widths, the same core architecture may be used in more specific bands, for example at VHF/UHF frequencies. This makes the system equally as suited to EW as it is to Mil Comms applications, where sampling sensitivity or frequency-agile protocols respectively are key to system function.
-
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.
-
TOB-BTS-6V4A -
Xiamen Tob New Energy Technology Co., Ltd
Power Bank Tester Used For Power Bank Capacity,Voltage And Cycle Testing. The TOB-BTS-6V4A Power bank tester is used for power bank quality detection, it can test the power bank capacity, voltage and life cycle performance with connecting computer.
-
K-1000 Resistive/Capacitive -
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
-
-
RD-Series -
Hilkar
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
K-1000 Resisitive -
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.