Showing results: 706 - 720 of 843 items found.
-
40-877A-002 -
Pickering Interfaces Ltd.
The 40-877A-002 (PXI) and 42-877A-002 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877A-102 -
Pickering Interfaces Ltd.
The 40-877A-102 (PXI) and 42-877A-102 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-870A-006 -
Pickering Interfaces Ltd.
The 40-870A-006 (PXI) and 42-870A-006 (PXIe) are 50Ω RF switches with 6 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40/42-870A has been minimized by careful attention to the mechanical and electrical design.
-
40-870A-106 -
Pickering Interfaces Ltd.
The 40-870A-106 (PXI) and 42-870A-106 (PXIe) are 50Ω RF switches with 6 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40/42-870A has been minimized by careful attention to the mechanical and electrical design.
-
42-877A-102 -
Pickering Interfaces Ltd.
The 40-877A-102 (PXI) and 42-877A-102 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-877A-002 -
Pickering Interfaces Ltd.
The 40-877A-002 (PXI) and 42-877A-002 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
778968-01 -
NI
The PCI-6512 is an industrial digital output interface, with eight banks of isolated channels. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6512 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
780176-01 -
NI
24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The NI‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The NI‑9425 offers isolation between the input and output banks from channel to earth ground. You cannot use the NI‑9425 in a CompactDAQ chassis to perform counter operations.
-
785044-01 -
NI
24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The NI‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The NI‑9425 offers isolation between the input and output banks from channel to earth ground. You cannot use the NI‑9425 in a CompactDAQ chassis to perform counter operations.
-
779139-01 -
NI
24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The NI‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The NI‑9425 offers isolation between the input and output banks from channel to earth ground. You cannot use the NI‑9425 in a CompactDAQ chassis to perform counter operations.
-
778971-01 -
NI
64-Channel, ±30 VDC, Sink Outputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6513 is an industrial digital output interface with eight banks of isolated channels. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6513 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.
-
778970-01 -
NI
The PCI-6513 is an industrial digital output interface, with eight banks of isolated channels. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6513 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
778836-01 -
NI
The PCI-6514 is an industrial digital I/O interface, with eight banks of isolated channels. With programmable power-up states, you can configure the initial output states in … software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6514 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of products for testing and measurement of battery from your critical power systems. It includes battery online monitoring system, battery tester for internal resistance/conductance, battery charger, battery load bank, battery data logger, battery charger/discharger and so on.
-
40-710-514 -
Pickering Interfaces Ltd.
This RF switching card has a bank of four individual high performance RF changeover switches (50 or 75 Ohm, Bi-directional) with very low insertion loss, suitable for handling signals up to 2.5GHz. Applications include aerial switching, routing high frequency signals into oscilloscopes and analyzers.