Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
Pyranometer First Class standard (ISO 9060 / WMO)
CMP 6
-
The CMP 6 pyranometer is intended for routine global solar radiation measurement research on a plane/level surface.Fully compliant with ISO-9060 specification for a First Class pyranometer, the CMP 6 features a sixty-four thermocouple junction (series connected) sensing element. The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long term stability characteristics
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I35-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
DC Josephson Voltage Standard
-
The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
CMOS Standard Image Sensors
-
The vision market is constantly looking for highly specialised, cost effective solutions where performance is not compromised. Teledyne e2v has over 40 years of heritage in imaging, with a background in the design and manufacture of CCD and CMOS image sensors.Capabilities include ultra-high speed and ultra-low noise. Teledyne e2v’s unique approach involves listening to the market/application challenges of customers and partnering with them to provide an innovative solution which brings real value to their systems.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1R1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Millimeter-wave Operation With Frequency Extenders For M980xA PXI VNA
S95560B
Vector Network Analyzer
banded vector network analyzer (VNA) using the M980xA PXI VNAs and N5252AW or N5262BW Frequency Extenders.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) Battery Probe
BIP-2
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 365Overall Length (mm): 9.27
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2262AG-1C1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Frequency Response Analyzers
350C Series
-
Venable Model 350c is the 3 channel successor to the original workhorse Model 350a/b that launched in 1986 and established Venable Instruments as a market leader. The contemporary 350c Series incorporates a 3rd channel, allowing the user to measure more transfer functions simultaneously with one sweep, such as source and load impedance. The 350c is the only frequency response analyzer in the industry that can measure absolute phase, using a reference channel.
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1P1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Frequency Multipliers
-
RF coaxial frequency multiplier (also referred to as a coaxial frequency doubler) PE8600 from Pasternack has SMA conectors and are 50 Ohm. Our SMA frequency multiplier is manufactured for a minimum frequency input of 1.5 GHz and a maximum frequency input of 5 GHz. This SMA microwave frequency multiplier / doubler output minimum frequency is 3 GHz and output maximum frequency of 10 GHz.
-
Product
Integrated Frequency to Voltage Converter
FV
-
The FV6 Frequency to Voltage Module provides a convenient method of converting up to six frequency signals to analog voltages that can be fed into common data acquisition equipment.
-
Product
Frequency and Phase Agile 120 MHz Signal Generator.
DDS8p
-
The DDS8p generates cosine, sine and ACMOS/TTL output signals. The frequency is programmable in 1µHz steps from 100Hz to 120MHz. The phase is 14-bit programmable. The DDS8p is controlled by a binary parallel interface that allows frequency and phase changes as fast as 600 nanoseconds. It is accurate to 1ppm and requires 5 VDC power.
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3D
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
HF Frequency Counter LXI, GPIB/IEEE48
53210A
-
For fast and accurate frequency and time-interval measurements, you need reliable devices in research and development. The Keysight 53210A HF frequency counter meets the requirements with its high accuracy, bandwidth and speed. Depending on the application and budget, choose one of the three available models. The connection to the PC is via USB, Ethernet/LXI or via GPIB.
-
Product
800MM 31.5In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles IP54 Standards
DL411
-
Advance Plus Trading Co., Ltd.
Model Number: DL411 Key Specifications/Special Features: 800MM 31.5INCH Digital Level with level bubbles, 2 hand shanks, LCD bright backlight display, IP54 standards 1. 800mm 31.5inch level with 2 bubbles, 800*28*64mm(L*W*H), net weight: 700g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. 2pcs Handshanks design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
Product
Frequency Meter up to 330 GHz
-
Frequency meter is intended for measuring frequency in range 70-330GHz.The Frequency Meter is based on sweepable heterodyne receiver. Fully outomated system allows to measure frequency without preslection frequency range.This solution is ideal for laboratory test measurement.
-
Product
High Frequency Synthesizer
HFS Series 1.25” x 1” x 0.25”
-
*Surface Mount Package *Broadband Designs Available *Optional Internal Reference *Optional Reference Detect Switch *Internal Reference Output Available *Off-the-Shelf Products Available
-
Product
Universal Frequency Counter LXI, GPIB
53220A
-
For fast and accurate frequency and time-interval measurements, you need reliable devices in research and development. The Keysight 53220 universal frequency counter meets the requirements for this with its high accuracy, bandwidth and speed. Depending on the application and budget, choose one of the three available models. The connection to the PC is via USB, Ethernet/LXI or via GPIB.
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1C1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Small Step Frequency Synthesizer
ZFR Series
-
ZFR series programmable frequency synthesizers combine multi-octave bandwidth, small step size, low phase noise, fast switching speed, and a compact package size to create a truly versatile synthesizer. The ZFR series can be tailored to the specific frequency range and control interface required, with programmable frequencies to 31 GHz.
-
Product
Gas Flow Standards
-
Fluke Calibration offers molbloc/molbox gas flow calibration systems to calibrate flow meters and controllers over a very wide range of flows. The systems are fast, precise and transportable and can be fully automated using COMPASS for Flow software. molblocs, which are the heart of the measurement system, are mechanically stable, gravimetrically calibrated laminar flow and sonic nozzle elements.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Charge Coupled Device (CCD) Standard Image Sensors
-
Teledyne e2v is the leading supplier of scientific grade Charge Coupled Device (CCD) image sensors for the most challenging low light imaging and spectroscopy applications.
-
Product
Frequency & Pulse Distribution
-
Timetech frequency distribution amplifiers and pulse distribution units.