Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
Global Standard Model For 4 Point Probe Sheet Resistance Automatic Measurement System
RT-3000/RG-1000F
-
*Fully automatic system for large sizes of flat panel with glass loading robot*Tester self-test function, Measurement position correction function, wide measurement range*Min. 0.1 mm meas. resolution and user programmable test pattern*Host (CIM) communication and 2-D/3-D Mapping software
-
Product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T30-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-2W1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Signature Model High Frequency Surge Testers
S
-
Bench size performance & durability with PJ's exclusive/unique High Frequency Technology capable of testing the integrity of any turn to turn insulation, including low inductance windings. These Digital Surge Testers come standard with a rack-mounted, Tektronix TDS1002, 1 Billion Samples/sec, real time, programmable, storage oscilloscope.
-
Product
Low frequency Amplifiers
-
Low-frequency amplifiersCurrent sourcesSystems with multiple amplifiersCustomized systems
-
Product
High Frequency Synthesizer
HFS Series 1.25” x 1” x 0.25”
-
*Surface Mount Package *Broadband Designs Available *Optional Internal Reference *Optional Reference Detect Switch *Internal Reference Output Available *Off-the-Shelf Products Available
-
Product
Standard IR Target Projectors
-
Santa Barbara Infrared’s 14000Zi Series reflective infrared target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies and 300 Series Target Wheels. SBIR also offers a standard athermal target projector with a 5.7° field of view (FOV).
-
Product
Standard Shackle Load Cell
SS-3.0
-
The DLM Standard Shackle Load Cell is a high strength marine grade cable connected Load Cell. Manufactured from industry leading Crosby or GN Shackles along with a stainless steel load pin.
-
Product
Radio Frequency Probes (Consumer) HF860RFm016G530MCXfS
1039104
-
Introducing the Radio Frequency Probes HF860, designed with precision to meet the demanding needs of RF applications. This coaxial probe features an impressive pitch of 6mm/236mil and operates effectively across a temperature range of -45°C to +100°C. With capabilities extending to a frequency of 6 GHz, it ensures reliable and accurate measurements in various settings. The product's design incorporates high-quality materials, including a beryllium copper plunger and brass barrel, both plated with gold for enhanced conductivity and durability.
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Unterminated for Pickering
-
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5A
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Primary Standard Capacitors
GenRad 1404 Series
-
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
Product
High-Performance Radio Frequency Probe HF860FAKRAf016G930MCXfSV1
1037081
-
The HF860FAKRAf016G930MCXfSV1 is a high-performance Radio Frequency Probe designed specifically for automotive applications. This coaxial probe, with an order code of 1037081, delivers exceptional performance with its ability to handle temperatures ranging from -45°C to +100°C and accommodate a continuous current of up to 10A. At a compact pitch of 6.50mm (256mil), it is engineered for precision and durability, making it ideal for rigorous automotive testing environments.This probe features impressive electrical characteristics, including a 50-ohm impedance and a frequency range of up to 6GHz, ensuring reliable and efficient signal transmission. The mechanical specifications include a preload force of 450cN and maximum travel capabilities that increase operational flexibility. The tip and barrel of the probe are constructed with high-grade materials, such as beryllium copper and brass, plated with gold for enhanced durability, corrosion resistance, and conductivity. The HF860FAKRA's robust design is complemented by its standard plug connection type, ensuring easy integration into existing systems.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3E
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1J-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency Dividers
-
These instruments feature a simple front-panel interface and provide low-jitter frequency division. A reset input (and manual switch) provides a method of synchronizing a high-speed input pulse train with lower-speed devices on the output.
-
Product
Standard 0.88 (24.90) - 4.50 (128.00) Switch Probe
SSP-5C
Switch Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Spring Force Remark: Force at switch point: 2.36 (66)Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 150Full Travel (mm): 3.81Recommended Travel (mil): 100Recommended Travel (mm): 2.54Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,210Overall Length (mm): 30.73Switch Point (mil): 25Switch Point (mm): 0.64
-
Product
Radio Frequency Probe HF860PCBCO016G530MCXfSV2
1038941
-
The HF860PCBCO016G530MCXfSV2 Radio Frequency Probe represents an optimal choice for precision measurements in various applications, particularly in consumer electronics. With a robust design characterized by a coaxial probe configuration, it offers enhanced performance across multiple frequencies, specifically designed to meet the demands of high-frequency applications up to 6 GHz. This probe provides excellent connectivity thanks to its MCX female connection type, ensuring reliable interfacing with various RF components.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Software Development Standards Compliance Solution
-
The most comprehensive development compliance solution; FDA, DO-178B/C, MISRA, JSF, PCI-DSS, ISO, IEC, and more. ntegrate compliance policies into the SDLC and team workflow. Accurately and consistently automate verification and validation tasks
-
Product
Integrated Frequency to Voltage Converter
FV
-
The FV6 Frequency to Voltage Module provides a convenient method of converting up to six frequency signals to analog voltages that can be fed into common data acquisition equipment.
-
Product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2LB-6
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Radio Frequency Probes (Industrial) HF890MMBXf-SMAf0112G910SMPmP
1042148
-
The Radio Frequency Probes (Industrial) HF890MMBXf-SMAf0112G910SMPmP is designed for high-performance applications, providing exceptional reliability and precision in environmental conditions ranging from -45°C to +100°C. Its innovative design features a pitch of 12.0 mm (472 mil) and incorporates both impedance and frequency ratings at 50 ohms and 12 GHz respectively, ensuring optimal signal integrity. This probe is particularly suited for demanding applications where electrical specifications, such as a continuous current rating of 10 A, are crucial for maintaining service stability.
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4L
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.