Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
Audio Frequency System
Locator Set / UL 30
-
Cable fault location with the BAUR Locator Set / UL 30. The audio frequency system Locator Set is used to exactly determine the alignment of cables and metal gas or water pipes. With various accessories, this system becomes a universal, indispensable device for power companies, industries, installation companies and water suppliers.* Output energy up to 50 VA* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72F-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Absolute Contamination Standards (ACS)
-
The Absolute Contamination Standard (ACS) is used to calibrate instruments which size and detect particles on the surface of bare silicon wafers. Use ACS to characterize particles, before particles characterize products.
-
Product
1229a Frequency Generator
-
Precise Time and Frequency, Inc.
The ptf 1229A utilizes the latest technological advances in precision frequency synthesizers to provide a multiple output, wide range, high precision frequency reference instrument, capable of delivering frequencies over the range of 0.1Hz up to 30MHz with a resolution of 0.1 Hz over the full range.The unit includes an external reference input to allow extremely high accuracy outputs at precisely the frequency required, together with a front panel indicator to verify “lock” to the external reference. The standard unit includes two independent frequency outputs of any frequency within the range, and provides both sine and square wave outputs for each frequency.An expansion module gives the capability to increase the number of independent frequency outputs up to a total of four frequencies, with sine and square wave outputs for each, giving a total of eight outputs.
-
Product
AC Measurement Standard
5790B
-
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
Product
WR5.1 Frequency Extension Solution, 140-220 GHz with VDI Extender Modules
CobaltFx 140 to 220 GHz
-
CobaltFx cost-effective millimeter wave frequency extension system allows you to build a scalable and affordable 5G testing solution.
-
Product
PXIe Frequency Reference: 10 MHz And 100 MHz
M9300A
Signal Generator
The M9300A PXIe frequency reference is a PXIe-compatible, compact, modular instrument that can be used with the Keysight M9301A synthesizer, M9310A source output, and M9311A modulator to create the world’s fastest vector signal generator, the M9381A. Create a CW source, the M9380A, by combining the M9300A with the M9301A and M9310A or use it as the 10-MHz or 100-MHz reference with other PXI solutions. Control the instrument through a soft front panel and programmatic interfaces tuned to your application development environment of choice.
-
Product
Low frequency Amplifiers
-
Low-frequency amplifiersCurrent sourcesSystems with multiple amplifiersCustomized systems
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L24-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Certified Leak Standards
-
Cincinnati Test Systems provides certified, high-performance air flow leak standards and tracer gas leak standards.
-
Product
Standard 0.83 (23.50) - 2.85 (80.80) Battery Probe
CCA-004
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 470Overall Length (mm): 11.94
-
Product
Standard Signal Loop-Powered
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation and 1: 1 transmission of 0/4 ... 20 mA current signals without additional auxiliary power. Also for use in hazardous areas. Particularly high reliability and certified functional safety up to SIL 3 / PLe.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20G
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Wireless Connectivity Digital Multimeter 6000 Count / NCV / SPT / Wide Frequency
MS-WP6DMM1
-
This is a compact, slim, light weight, pocket size external wireless connectivity Digital Multimeter integrated with 6000 Count, True RMS auto and manual measurement.
-
Product
Coating thickness XRF Standards
-
We manufacture high accuracy reference standards capable of calibrating virtually any X-Ray Fluorescence (XRF) coating thickness and composition analysis system.
-
Product
Frequency Counter (225MHz - 18GHz)
S43180
-
S43180 series high-precision frequency counter is a high-precision frequency measurement instrument. It has a frequency measurement resolution of 10 bits per second. The whole machine scheme adopts countdown technology and digital interpolation technology to realize the high-precision measurement of the instrument. It has measurement functions such as frequency, period, frequency ratio and powerful mathematical statistics operations (maximum value, minimum value, average value, PPM, standard deviation, Allan variance).S43180 series has reliable performance, complete functions, high measurement accuracy, wide frequency measurement range, high sensitivity, large dynamic range, high cost performance and easy to use. It is especially suitable for frequency measurement in scientific research and measurement fields such as aerospace, crystal oscillators, and components.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-F180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard Voltage 50 Pin D-Type Connectors for Pickering
-
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Explosion Proof Area Hydrogen Monitor
HY-ALERTA™ 2620
-
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L18-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I40-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Power Frequency Transducer
PP1S
-
1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1W1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Signal Generator Frequency Extenders
FES
-
These frequency extension modules easily connect to the output of your signal generator so you have high-performance source for your DUT characterization activities. Characterize your DUT with the confidence that the superior performance in terms of output power, spurious and harmonic will provide product accurate results.
-
Product
Oxygen/Nitrogen/Hydrogen Analyzers
EMGA-Expert
-
The characteristics and performance of metal and solid materials, including steel, various other metals, ceramics, and electronic materials, are determined by the amount of oxygen, nitrogen, and hydrogen. Analyzing elements in such materials at high accuracy and with a small amount has become increasingly important in the study and performance analysis of materials.The EMGA Series Oxygen/Nitrogen/Hydrogen Analyzers significantly reduces analysis time and costs while enhancing analysis accuracy and functionality. Pursuing also usability, the EMGA Series strongly supports improved efficiency in material research and development and quality control.
-
Product
125 Mbps Low Frequency Bit-Error-Ratio Test System
OPBK125
-
The OPTELLENT OptoBERT™ OPBK125 is a costeffective easy-to-use bit-error-ratio (BER) measurement system for testing components and systems in R&D and manufacturing environments as well as field installations. It incorporates a pattern generator, clock recovery circuits, and a bit-error-ratio analyzer in one compact module that provides electrical interfaces at data rates up to 125 Mb/s.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2T
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64