Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72J-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-6
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
0.5-2.4GHz Instantaneous Frequency Measurement Unit
DR063-M2
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.
-
Product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2P
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard VXI Module Shield Kits Without Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Same design described above but without the address switch opening.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Standard Optical Interleaver
-
An innovative technique for expanding the number of channels per fiber involves an optical device, called an optical interleaver. For example, in most DWDM equipment, the standard channel spacing is 100 GHz. But spacing the signal-carrying frequencies every 50 or even 25 GHz can double or even quadruple the number of channels per fiber. This job is accomplished by an optical interleaver. Such a device takes two multiplexed signals with 100-GHz spacing and interleaves them, creating a DWDM signal with channels spaced 50 GHz apart. The process can be repeated, creating even denser composite signals with 25-GHz or 12.5-GHz spacing. The signals at the receiving end are recovered with the same devices used as splitters or optical de-interleavers. Thus, devices and/or networks can be upgraded without requiring that all devices be upgraded, or network bandwidth can be increased.
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4C
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HL-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
UV SHG Cavity Compact Frequency Quadrupling Module
SolsTiS ECD-X-Q
-
SolsTiS ECD-X Q extends the range of the SolsTiS platform into the deep UV providing unrivalled power and tuning. SolsTiS ECD-X-Q is used in combination with the ECD X doubling cavity (wavelength ranges between 210–250 nm) or the EMM mixing module (wavelength ranges between 250–300 nm).
-
Product
Frequency Dividers
-
Precision Test Systems manufacturers' various divider boards as options to its range and frequency standards and distribution amplifiers.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard Systems With Customization
-
When the cable assembly product offerings on the website – cable, connectors, and markers – do not meet the needs of your application, Teledyne Storm Microwave provides our Standard with Features (SWF) offering. SWF allows the customization of your cable assembly needs by discussing your needs with our Applications Engineering professionals and without needing a detailed specification.
-
Product
Frequency Synthesizers 50 MHz to 21 GHz
Luxyn Model MLVS-0520
-
Lyxyn synthesizers are ideal main local oscillators in Receiving Systems, Frequency Converters and Test & Measurement Equipment. MLVS-0520 is VCO-based and provides 0.001 Hz frequency resolution over the 50 MHz to 21 GHz frequency range. Output power level of +15 dBm is provided throughout the full frequency range. Full band switching speed is 50 μsec maximum. The MLVS-0520 is 4” x 3.6” x 0.94” high.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L18-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
AC Power Source, Frequency Converter
BL1350 Series
-
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
Product
Xytronic Three-Phase Site Analyzing Standard
RADIAN RX-3X-A
-
The RX-3X-A Xytronic Three-Phase Site Analyzing Standard brings precision measurements, normally associated with laboratories, to the meter site at a surprisingly affordable price. How is this possible? Radian has always designed state of the art precision measurement equipment with extreme high and low operating temperatures in mind – all site analyzers are tested at -20C to +70C. Couple precision measurement with ruggedness, throw PCSuite software automation into the mix, you have the premier RX Site Analyzing solution to meet the most demanding site measurement challenges
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1A-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Phase Frequency Detectors
-
Analog Devices phase frequency detectors offer high performance and ultralow phase noise in a low cost, compact package. Our devices can significantly improve frequency lock time, and include automatic and configurable lock detect indicators.
-
Product
High Frequency LCR Meters up to 30MHz
11050
-
Chroma Systems Solutions, Inc.
The Chroma 11050 Series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range 75kHz~30MHz/1kHz~10 MHz/60Hz~5MHz suitable for analyzing component characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.
-
Product
Standard 0.87 (24.70) - 5.40 (153.00) Battery Probe
BIP-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 394Full Travel (mm): 10.00Recommended Travel (mil): 315Recommended Travel (mm): 8.00Overall Length (mil): 1,220Overall Length (mm): 31.00
-
Product
Standard Flexiforce Sensors for Force Measurement
FlexiForce
-
FlexiForce force sensors are ultra-thin and flexible printed circuits, which can be easily integrated into force measurement applications. These sensors are available for purchase in our online store.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
Radio Frequency (RF) Testing
-
Comprehensive testing and certification services helping you ensure that your wireless or radio devices achieve compliance to international regulatory RF or immunity requirements.
-
Product
Hydrogen Peroxide Gas Concentration Analyzer
PI2114
-
The Picarro PI2114 gas concentration analyzer measures hydrogen peroxide levels as low as 4 ppb to help avoid oxidation and safeguard drug stability. Major pharmaceutical, CMO, and isolator companies use Picarro hydrogen peroxide analyzers in high-potency API and biologics manufacturing and in aseptic fill and finish. The PI2114 analyzer is fast and easy to use. It doesn’t need chemicals or consumables. And it requires infrequent calibration and maintenance to minimize operating costs.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
Product
High Frequency Infrared Carbon and Sulfur Analyzer
CS-8820
-
Wuxi Jinyibo Instrument Technology Co., Ltd.
Infrared detector with low noise, high sensitivity and high stability. The modular design of the whole machine improves the reliability of the instrument. The electronic balance is automatically connected. WINDOWS full Chinese operation interface, easy to operate, easy to master. Dynamic display of various data and carbon in the analysis process. Measuring linear range is wide, and can be expanded. High-frequency circuit design is reasonable, high-frequency furnace power is adjustable, suitable for different material sample analysis requirements. The automatic cleaning device of the burner can reduce the influence of dust on the analysis results. The burner heating device makes the conversion rate of sulfur tend to be consistent, which improves the stability of sulfur determination. Measuring linear range is wide, and can be expanded. The software is fully functional, providing more than forty functions such as file help, system monitoring, channel selection, mathematical statistics, result correction, breakpoint correction, and system diagnosis.
-
Product
Amplifier for the Frequency Range from 2 Hz to 50,000 Hz.s
Trig-Tek™ 203M
Amplifier
Versatile amplifier covers the frequency range from 2 Hz to 50,000 Hz.s and provides has three simultaneous outputs
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T1-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
1KVA Variable Frequency Power Source
CX- 9001
-
Shenzhen Chuangxin Instruments Co., Ltd.
1KVA Variable-Frequency Power Source