Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HC-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Three Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
Product
Primary VoltageE Standard: Cryocooler (Closed- Cycle Refridgerator) System
-
The Hypres Primary Voltage Standard System with cryocooler (closed-cycle refrigerator) is a complete, computer controlled system implementing a variety of voltage calibration functions. This system configuration is a cryogen-free complete Primary Voltage Standard System with parameters that are identical to the liquid helium version.
-
Product
European Standard for Remote Reading of Measuring Devices
M-Bus
-
M-Bus (Meter-Bus) is a European standard for remote reading of measuring devices. M-Bus is predominantly used in buildings, for example in electricity meters, gas meters, water meters or other types of consumption meters. It is also used for various sensors and actuators.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3E
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72J-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
UV SHG Cavity Compact Frequency Quadrupling Module
SolsTiS ECD-X-Q
-
SolsTiS ECD-X Q extends the range of the SolsTiS platform into the deep UV providing unrivalled power and tuning. SolsTiS ECD-X-Q is used in combination with the ECD X doubling cavity (wavelength ranges between 210–250 nm) or the EMM mixing module (wavelength ranges between 250–300 nm).
-
Product
Standard Test Chambers
-
HIACC Engineering & Services Pvt. Ltd.
Designed for testing the durability, safety, and performance of products under various conditions.
-
Product
Uniform Light Sources, Luminance Standards
-
Uniform light sources for the adjustment of pixels and intensity of image sensors and cameras as well as for the calibration of luminance and spectral radiance or in other words: Solutions for Imaging, Sensing & Remote Sensor Calibration.
-
Product
FlexVNX+ 3-Slot Test And Development Platform Aligned To SOSA And VITA 90 Standards
39S03VPXZZY2VAND
-
Elma’s 3-Slot FlexVNX+ Development Chassis is the industry’s first compact, SOSA™ and VITA-90 aligned VNX+ platform, purpose built for rapid board bring-up, validation, and test of plug-in cards (PICs).
-
Product
Standard 0.83 (23.50) - 2.85 (80.80) Battery Probe
CCA-004
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 470Overall Length (mm): 11.94
-
Product
1KVA Variable Frequency Power Source
CX- 9001
-
Shenzhen Chuangxin Instruments Co., Ltd.
1KVA Variable-Frequency Power Source
-
Product
SF6 Filled High Precision Standard Capacitors
YL Series
-
Shanghai Jiu Zhi Electric Co., Ltd.
The SF6 insulated standard capacitor is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tanδ of all types including cables, capacitors, bushings, instrument transformers and power transformers. Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L24-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Time And Frequency Meter
-
A high-precision electronic instrument that measures the frequency of periodic signals and the time interval between events.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1E
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Four Terminal Pair Standard Resistor Set
42030A
Programmable Resistor Module
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Universal Frequency Counters
GT210PXI-2
-
GuideTech’s GT210PXI-2 3U form factor, meets industrial standard chassis with an expandable platform, achieving optimal test system with optimal cost. The ability to precisely resolve frequency and time yields both increased accuracy as well as reduced measurement time.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1R1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard Handheld Display
TW-3.0-S
-
The TW-3.0-S Standard Handheld Display is a modern, slimline, multifunctional load monitoring device which is unique to DLM. This innovative design is built with the user in mind. It has a large, high quality LCD screen which is optically bonded removing the need for a back light and improving clarity in bright sunlight. For ease of use each handheld can be given a customisable friendly name made visible on the screen to make instant identification possible. This multi featured high precision unit ensures reliable load readings while also being simple to operate. It can be used in conjunction with any DLM manufactured load cell, just look for the d+ logo on our products.
-
Product
Frequency Counters/Timers
-
The Tektronix FCA Series frequency counter / timer / analyzer packs the functionality of a frequency counter, frequency meter and timer into one feature-rich instrument. With unprecedented resolution, you can capture very small frequency and time changes. Tektronix frequency counters and timers offer comprehensive analysis modes, including measurement statistics, histograms, and trend plots.
-
Product
Explosion Proof In-line Hydrogen Process Analyzer
HY-OPTIMA™ 2700 Series
-
The HY-OPTIMA™ 2700 Series uses a solid-state, non consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases. The HY-OPTIMA™ 2700 Series is ideal for applications where real-time, hydrogen specific measurements can enhance process plant efficiencies, diagnostics and maintenance management.
-
Product
Standard Pitch Spring Probes
-
Other than spring probes with gold plating, we have spring probe with anti-solder migration coating and plating that were developed by KITA. We also have anti-solder migration material for plunger tip. These are all included in “MARATHON” series. They have wide range of tip type for various use for every popular total length.
-
Product
NTSC Standard Pattern Generator
PG315N
-
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
Product
Three Phase High Precision Reference Standard Energy Meter
SY3102
-
Hong Kong Songyang Industrial Ltd.
There are three ports for pulses to output. And its constants can be set automatically or manually. Types of constants can be set also: active power, reactive power, apparent power, voltage, and current.
-
Product
CPCI-S.0 Standard Compliant Peripheral Board Controlled by a PCIe Channel Derived from the Backplane Connector P1
MIC-3820
Backplane
MIC-3820 is a 2.5" on board SSD/HDD carrier board running at SATA Gen3 speed. A fast swap of the drive can be accomplished via a reserved thumb screw to help open a door on the front panel and eject the drive. The excellent mechanical design makes it easy to replace modules.
-
Product
Frequency Response Analyzers
6300 Series
-
The Venable Model 6300 Series is our popular 2-channel hardware/software system supplying the same functionality as all Venable FRAs, with the 6300 leading the industry with more integrated testing and measurement capabilities than any other instrument in its class.





























