Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
CMOS Standard Image Sensors
-
The vision market is constantly looking for highly specialised, cost effective solutions where performance is not compromised. Teledyne e2v has over 40 years of heritage in imaging, with a background in the design and manufacture of CCD and CMOS image sensors.Capabilities include ultra-high speed and ultra-low noise. Teledyne e2v’s unique approach involves listening to the market/application challenges of customers and partnering with them to provide an innovative solution which brings real value to their systems.
-
Product
Frequency generator
F170
-
The new F170 square wave frequency generator is based on the same hardware as the F165. It has all the features of the F165 plus 3 additional internal channels for a total of 6 programmable channels. It can run standalone up to 1500 program files copied from a PC or Mac or created from the keypad
-
Product
1202a High Frequency Distribution
-
Precise Time and Frequency, Inc.
The ptf 1202A High Frequency Distribution amplifier provides high performance frequency references for laboratory or system use requiring distribution at frequencies of 30MHz and above.The ptf 1202A is especially designed to distribute the high frequency input signal to 12 separate outputs, with minimum signal distortion and maximum isolation between individual output signals.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-7
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-4V1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
DC High Current And Power Resistance Standards
-
Specialized high-accuracy electrical metrology equipment designed to measure, source, and calibrate high direct current (DC) and power levels with extreme precision and low uncertainty.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Standard DIP Socket with Solder Tail Bifurcated Contacts
Series 511
-
Standard DIP Sockets with Wire Wrap Bifurcated Contacts. Features: Standard DIP sockets are available with solder tail or wire wrap pins, all with bifurcated contacts. Consult Data Sheet No. 12005 for wire wrap pins. Aries offers these standard DIP sockets in more sizes than any other manufacturer.
-
Product
AC Voltage and Frequency Transducers
NMTU/F
-
The NMTU/F device is an AC voltage and frequency transducer with two independent analogous outputs. The A output measures AC voltage, the B output measures the frequency of input voltage. That´s why one single NMTU/F transducer is able to replace two customary transducers, thus making it possible to achieve significant savings in installation space.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25F-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.63 (46.00) - 4.50 (128.00) Battery Probe
CP-059-19
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72J-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Radio Frequency Probes HF77MATEAXm0112G540MSMPmP
1035527
-
The Radio Frequency Probes HF77MATEAXm0112G540MSMPmP is engineered for high precision and reliability in the realm of coaxial probing applications. With a pitch of 4.00 mm, this probe can operate effectively within a temperature range of -45°C to +100°C, ensuring versatility for various environments and conditions. Capable of handling continuous currents up to 0.50 A and operating at a frequency of 12.00 GHz, this model delivers exceptional performance for RF testing and measurement tasks.
-
Product
Radio Frequency Probes HF77HMTDf0220G1500HMTDmF
1171006
-
The HF77HMTDf0220G1500HMTDmF Coaxial Probe is designed with precision and versatility in mind, particularly suited for applications requiring high-frequency connectivity. This coaxial probe features a pitch of 19.5 mm (748 mil), making it a reliable choice for various electronic testing scenarios. The robust design is complemented by a nominal travel of 2.50 mm and a maximum travel of 3.50 mm, ensuring optimal performance while catering to demanding specifications in electrical measurements. With a frequency capacity of up to 20 GHz and an impedance of 100 ohms, this probe guarantees effective signal transmission suited for high-bandwidth applications.
-
Product
ITA, G10, 10 Module, 0.5" Standard thickness
410104123
ITA
ITA, G10, 10 Module, 0.5" Standard ThicknessUses VPC 90 Series Modules.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-J100-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2LB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z1-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
The Standard R&D Wafer-Lifetime Tool
WCT-120
-
Best available lifetime measurement accuracy. Measure lifetime and surface recombination for a wafer of any quality or crystallinity.
-
Product
Low Phase Noise Frequency Synthesizer
-
Corech’s low phase noise frequency synthesizer series generates precise and stable frequency signals across a wide frequency range, available in SPI serial interface. These cost competitive, rugged and compact module are the ideal choice for RF & Microwave systems such as communication systems, test and measurement equipment, radar systems etc.
-
Product
GPS Locked Mm-Wave Frequency Meter up to 170 GHz
-
Elva-1 specially designed GPS synchronized mm-wave frequency meter GPSFC-xx series. This solution allows to provide independent frequency measurement in different laboratories with absolute accuracy.
-
Product
Standard Precision GNSS Module
AIW-213
-
Half size mini-PCIe form factorStandard Precision GNSS L1 band92 Channels u-blox NEO-M9 engine (GPS, GLONASS, BeiDou, Galileo, QZSS and SBAS)USB 2.0 communication interfaceSupport Dead Reckoning (DR), Including IMU and Oscillator2 second TTFF for Hot Starts, Open sky code start 24 second.Accuracy 1.5M CEPOperating temperature: -40°C ~ +85°C / -40°F ~ 185°F
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I35-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-2
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
PXI Standard Programmable Resistor Modules
-
Pickering's PXI Standard Programmable Resistor Modules include fully programmable resistor and potentiometer modules for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Modules can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection. For applications with more demanding accuracy and resolution requirements, consider our Precision Programmable Resistor Modules .
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF120
-
Lifasa - International Capacitors, SA
Accessories: Differential protection
-
Product
Low Frequency 3-Way Power Dividers To 1500 MHz
-
Pulsar Microwave manufactures 3-way power dividers from 1 MHz to 1.5 GHz in both surface mount and connectorized packages. They are rated for an input power of 1 watt maximum for a load VSWR of 1.20:1 or better. This series of 3-way power dividers are currently offered in four outline packages. The hermetically sealed outline 301 and surface mount outline B are useful in portable applications where space is premium. Outlines 412 and 433 are connectorized versions in cross or in-line format, respectively.
-
Product
Audio Frequency Output Power Meter
-
PGP Electronics Private Limited
PGP Electronics AF Output Power meter, model 3301provides reliable measurement of Audio Frequency Output Power. The audio power output meter, measurable from 0.01mW to 30W in 12 decades with 10 different termination impedances with both balanced and un balanced inputs. The instrument is very useful to conduct students projects, design and test simple sub systems in laboratories. New improved design features provides reliable working even in adverse environments.
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.





























