Filter Results By:

Products

Applications

Manufacturers

Mains

chief conduit of electricity, gas or water distribution.


Showing results: 496 - 510 of 664 items found.

  • PXI Single 8x2 1-Pole 10A Power Matrix

    40-551-002 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • 10-Ch Pneumatics CAN

    YAV90PNE - 6TL Engineering

    The YAV90PNE is a complete “plug & play” pneumatics subsystem controlled by CAN, for ATEs with Virginia Panel receiver. Thanks to this module, pneumatics actuators that are commonly used in the fixture side of an ATE, can be controlled. 10 3-way micro-valves are able to contorl 10 simple effect actuators or else 5 double effect ones. The module includes input for the position sensors. A pressure sensor is also included, so that the system air mains working pressure can be set between a minimum and a maximum.

  • PXI Single 8x4 1-Pole 10A Power Matrix

    40-551-001 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, also available with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI Single 4x4 1-Pole 10A Power Matrix

    40-551-003 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • EMI Receiver System

    EMI-9KC/EMI-9KB - Lisun Electronics Inc.

    EMI-9KB is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.

  • Hall Effect Measurement system

    HMS-3300 - ECOPIA

    Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.

  • 180V-260V AC Socket Tester (For UK)

    1941 - Peaceful Thriving Enterprise Co Ltd

    *With UKCA Approval.*LED indicators & Digital display.*Test for 180-260VAC circuit.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 4W*Frequency: 50Hz

  • BDV Transformer Oil Test Sets

    Neutronics Manufacturing Co.

    NMC''s Transformer BDV Oil Test Set is a portable unit as per relevant Indian Standard Specification IS :6792 :1992, suitable for operation on 230 / 240 Volts, A.C. 50 Hz. A three core flexible cable is connected to the unit with three pin socket to connect the mains. The H.V. Transformer is a completely dry, resin encapsulated with two H.V. terminals with mounting saddles. The center point of the transformer is earthed, so that the voltage of each terminal to earth is only half the test voltage.

  • Digital Vibration Control System

    DSC-98000MJ - EMIC Corporation

    The DCS-98000MJ series vibration control system is the most suitable digital vibration control system used for an electrodynamic vibration testing system to perform vibration evaluation test for highly advanced industrial products. The system is a highly stable Embedded Computer based system, the computer on which the Intel® Celeron™ Processor is installed. It consists of the vibration control, the communication Dynamic Control Unit (main DCU), and the expandable measuring input/output Dynamic Control Unit (sub DCU).

  • PXI 8 x DPDT Power Relay Module, 5A

    40-157-001 - Pickering Interfaces Ltd.

    40-150/151 modules have 8xDPST or 12xDPST power relays, suitable for switching inductive/capacitive loads up to 5A at 250VAC. 40-155/156 modules have 8xSPDT or 16xSPDT power relays and 40-157 is configured as 8xDPDT. Power relay modules are intended for switching heavy AC or DC loads or for slave switching large external relays, contactors and solenoids. The 40-150 series of power relay module are suitable for applications requiring switching of either mains voltage or DC current.

  • High-Frequency Amplifier

    Dr. Hubert GmbH

    The RF broadband power amplifiers from the A1020 product range are robust class -A/-AB amplifiers for EMC testing and general laboratory applications. Stability under all load conditions occurring in practice, a wide frequency range, low degree of distortion, and a fair purchase price are the main characteristics of these amplifiers. Optimum cooling is ensured through implementation of a high-power heat sink with temperature-controlled fans. Sophisticated protection equipment ensures hardware integrity, even at extreme load conditions.

  • Traveling Wave Tube Amplifier

    Skylink Microwave

    Skylink a leading provider in design and manufacture a wide range of traveling wave tube amplifiers(TWTAs) and microwave power modules(MPMs).Skylink's new generation of MPMs are based on a modular design, and use new technology, material and computer simulation system to improve weight, size and efficiency.Our main MPM series frequency covers range from 2 to 40GHz and providing more than 100W. They combine a helix TWT, a solid state amplifier and an integrated power conditioner in a compact package.

  • Audio Frequency System

    Locator Set / UL 30 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR Locator Set / UL 30. The audio frequency system Locator Set is used to exactly determine the alignment of cables and metal gas or water pipes. With various accessories, this system becomes a universal, indispensable device for power companies, industries, installation companies and water suppliers.* Output energy up to 50 VA* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output

  • Multiparameter Water Quality Meter

    ProDSS - YSI Incorporated

    Handheld multiparameter instrument with multiple cable options. The YSI ProDSS (digital sampling system) handheld multiparameter meter provides extreme flexibility with two main cable options. Choose between the fully loaded 4-port cable assembly outfitted with any four DSS sensors (with depth or no depth) or the ODO/CT probe and cable - where you get accurate DO measurements every time with an optical dissolved oxygen sensor with an inline conductivity sensor, allowing for real-time salinity compensation.

  • 8x4 Power Matrix, 2-Pole, 2xGMCT

    40-550-902 - Pickering Interfaces Ltd.

    This version of the 8x4 power matrix is for heavy current/low duty cycle power switching. Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current.

Get Help