Filter Results By:

Products

Applications

Manufacturers

Mains

chief conduit of electricity, gas or water distribution.


Showing results: 661 - 672 of 672 items found.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Rugged, Long Gauge Length Extensometers

    Model 3543 - Jinan Testing Equipment IE Corporation

    With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Circuit Breaker Analyzers & Timers

    CAT Standard Series - IBEKO Power AB

    Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

  • 60kw off grid power inverter 110/220V split-phase output converter

    SDP-60KW - Zhejiang Sandi Electric Co., Ltd

    Our SDP series Off Grid Pure sine wave inverter is one of the most advanced DC to AC conversion products in the world, it is suitable use for areas without electricity, vehicles, ships, solar energy, wind turbine and other renewable energy systems and etc, can supply power and provide guarantee effectively for the areas with traffic inconveniences, in the mountains, pastoral, border, island and other areas without electricity. It has the main advantages of high quality sine wave AC output, microcomputer control, humanness design, and it is high efficiency and low no-load loss, and no pollution. The inverter can also supply AC power to all kinds of electric equipment, air conditioners, motors, refrigerators, lights, TV, electric fans and other industrial power supply.1. Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more.2. Intelligentized, modularized, simple structure design with powerful function.3. Two kinds of start mode: Step-down Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control.4. The output frequency can be setting via LCD panel, it’s very convenient for customer.5. The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy ±1%.6. The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.7. Pure sine wave output. With good dynamic response less than 50MS, waveform distortion rate smaller, higher conversion efficiency and stable output voltage.8. Low Frequency Transformer, which ensures that inverter has high efficiency.9. High conversion efficiency, Max. Efficiency≥94%,if 48VDC input,the efficiency can more than 85%.10. Adopts black pure aluminum radiator, which confirms the best radiating performance.11. Powerful data display function. LCD can display the DC input voltage, output frequency, phase voltage, phase current, AC bypass input voltage, output power KWH, time and date, temperature, fault code display.12. Wide input voltage can be set according to customer’s requirement. Input voltage range can be selected from 150-400V or 300-600V or 400-800V.13. Wide input voltage can work without battery and solar charge controller,save more cost and With MPPT wide voltage input function, maximum use of solar power

  • Lithium battery 128kWh Lifepo4 Battery pack 280Ah with BMS for Solar Energy Storage System

    SPVLI-128kWh - Zhejiang Sandi Electric Co., Ltd

    ESS lithium battery system is composed of lithium battery modules, BMS system, PV charge controller, AC/DC Charger, central control unit CCU, temperature detector, integrated structure and other parts; the solar panels in the system are battery storage and power for output; BMS module completes the detection and control of voltage, current, temperature, SOC, SOH and charging and discharging related parameters of power battery pack; PV controller and inverter realize bidirectional AC/DC function to meet the charging and discharging conversion demand of power battery pack; each detector is used to monitor the ambient temperature in real time to ensure the safety of the system.1. Standardized components, modular architecture, easy for expansion2. High energy density, small footprint, short construction period, strong environmental adaptability3. Battery module within the layered stack design, with more than 10 years of long design life 4. Long Cycle Life LiFePO4 Lithium ion Battery system from 20KWH—500KWH optional5. The use of international advanced Mitsubishi IPM module and intelligent power module, with high power fast adjustment capability6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system8. Product communicates with the monitoring platform in real time through RS232, CAN communication interface, and reports various records in time to ensure real-time monitoring of the battery pack of the monitoring platform9. PV charge controller adopts three charging stages (buck charging, equalize charging and float charging) which can maximize the utilization of PV modules and batteries10. Colorful LCD display all module working information and statusPerformance characteristics:Small size and light weight, Maintenance-free;Environmental protection and pollution-free materials, no heavy;Accurately estimate the state of charge of the battery pack, that is, the remaining power of the battery, to ensure that the power of the battery pack is maintained within a reasonable range;Built-in BMS management system with comprehensive protection and monitoring control functions;5" LCD screen display, easy to operate, can check the temperature, voltage, working status, discharge current, dynamic and static SOC algorithm of a single cell, local display of alarm info, alarm level distinction, accurate positioning of abnormal cells;Main control MCU can be centrally controlled and manage peripheral settings (AC charging module, inverter module, solar charging module) to adjust the charging current and voltage of peripheral devices according to the battery charging curve, making the system more reliable;BMS battery management system, with SOC automatic calibration and high current passive balance function, combined with perfect operation control and management strategy, to achieve accurate and efficient management;EMS energy management system, BMS with solar controller/AC charger, inverter centrally manages charge and discharge, effectively controls the charge and discharge current within the cell usage conditions, protects the cell and extend its service life;SpecificationLithium battery 128kWh Lifepo4 Battery pack 280Ah with BMS for Solar Energy Storage SystemModel SPVLI-128KWHType of cell LiFePO4 (Lithium iron phosphate)Battery cell configuration 3.2V 280AH 144PCSRated capacity (KWH) 128kwhNominal capacity (AH) 280AHNominal voltage (VDC) 460VOperating voltage range (VDC) 375-540VRecommended Charge Voltage (VDC) 504VRecommended discharge cutoff voltage (VDC) 382VRecommended charge current(A) 140AMax Charge Current (A) 280ARecommended discharge current (A) 140AMax Discharge Current (A) 280ACharge temp range 1~45℃Discharge temp range -10~45℃MPPT Solar Charge Controller InputMaximum. Input voltage of solar array(Vdc) <900VdcBattery system voltage 460VDCMaximum power of solar array 64KWMaximum charge current(A) 140AEqualization charging voltage (Vdc) 511.2VEqualize charging recovery voltage (Vdc) 486.72VOver voltage disconnect voltage (Vdc) 525.6VOver voltage recovery (Vdc) 518.4VWorking temperature -20~50℃Protection level IP20Communication interface CAN2.0, BMSDisplay 5" LCD, EnglishCooling system Fan coolingWorking Altitude (m) ≤3000mReference Weight (Kg) 1530KgReference size (W*D*H mm) 1200*1120*1950mm

Get Help