Showing results: 1006 - 1020 of 1892 items found.
-
MC140i -
Powertek LLC
Multifunction calibrator MC140i is ideal for calibration of voltmeters, ammeters, DMMs and panel meters. AC/DC voltage 1uV to 1000V. Current 50uA? to 1000A using test coil. Deviation control along readout. 0.0035% basic dc accuracy. 0.03% basic ac accuracy. Supplied with RS232 interfaces. UKAS/NIST Traceable
-
MRC ltd.
* Three reading modes* Smart-Read function. More stable the reading with auto recognition end-point* Cont-Read function. It is clear to read the sample changing in measurement process* Timed-Read function. Auto timed to store the reading* Auto upgrade hardware* Power-off protection, protect your data* Remind the electrode performance and calibration.
-
MRC ltd.
* Field calibration of probes* Automatic probe recognition* Field replaceable probes* Battery backup* Independent channel alarms* 60 assorted charts included* LCD display (2 line)* Alarm delay: NO DELAY, 10 mins., 30 mins., 1 hr. or 2 hrs.* Real time data view.
-
cm-145 -
AudioControl Industrial
The CM-145 is a very low noise, flat frequency response, omni-directional microphone built to IEC651 Type 1 standards and comparable to the B & K 4006. This is an electret condenser microphone with a 1/2 diaphram of nickel-copper alloy. Included with the microphone is a shock mount, foam lined wood storage box and individual calibration chart.
-
OAI
OAI’s UV Measurement Instrumentation are the standard for Semiconductor Lithography, MEMS, Sensors, Microfluidics, UV Curing, 3-D Printing, Sterilization, Water Purification and Solar/PVC industries. For over 45 years our meters have earned a reputation for accuracy, repeatability and dependability. We offer full calibration and support services worldwide.
-
DAQ-2208 -
ADLINK Technology Inc.
- 12-bit A/D and sampling rate up to 3MS/s- 96-CH single-ended or 48-CH differential inputs- 1024-configuration channel-gain queue- Analog and digital trigger- Bus-mastering DMA with scatter-gather technology- Full auto calibration- Multiple cards synchronization- 2-CH 12-bit 1Ms/s analog outputs with waveform generation functionality (DAQ-2204 only
-
5790B -
Fluke Calibration
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
IMADA, Incorporated
Automatic Breakaway Torque Tester can be used to verify the actual tightened torque of a bolt. Torque controlled power tools are set to apply consistent torque, but fasteners are not necessarily tightened to that value if the tools are out of calibration. Breakaway torque tests require a skilled, experienced operator to sense when the bolt begins to breakaway.
-
Kaman Fuzing & Precision Products
High precision electro-mechanical assembly is also one of Kaman's core competencies. Many of our OEM customers use our products in larger assemblies. They benefit from allowing us to build the higher-level assembly, because our product is then part of in-situ calibration, the optimum solution for high performance and high reliability.
-
Extech 650470 -
Extech Instruments Corporation
The Extech 650470 is a set of Tripak Dry Powder Buffer Capsules. It provides convenient calibration solutions in capsules for pH meters. Includes 3 vials (10 capsules each) of 4 pH, 7 pH, and 10 pH dry powder buffers as well as one dispenser vial of color key preservative.
-
Traceable Products
An individually-numbered Traceable® Certificate provided with each unit, assures accuracy from our ISO/IEC 17025:2005 (1750.01) calibration laboratory accredited by A2LA. It indicates traceability of measurements to the SI units through NIST or other recognized national measurement institutes (NMI) that are signatories to the CIPM Mutual Recognition Agreement.
-
Traceable Products
An individually-numbered Traceable® Certificate provided with each unit, assures accuracy from our ISO/IEC 17025:2005 (1750.01) calibration laboratory accredited by A2LA. It indicates traceability of measurements to the SI units through NIST or other recognized national measurement institutes (NMI) that are signatories to the CIPM Mutual Recognition Agreement.
-
Morehouse Instrument Company Inc.
Morehouse Universal Calibrating Machines (UCM) are an easy to use, cost-effective, hydraulic force calibration system that lasts for generations. UCMs built in the 1950s are still operating today! The UCM can be used to calibrate both tension and compression instruments in accordance with ASTM E74, ISO 376, and other internationally recognized force standards.
-
LDC-5/D -
Doble Engineering
For LDS-6. Double impulse calibrator. For external calibration of the standard PD measuring circuit according to IEC 60270 (single pulses). PD measurements on long cables and in accordance with standards requiring the verification of the double pulse behavior of the employed PD measuring system. Produces these standardized time parameters according to the IEC 855-3.
-
TorqueLab® LTT-Series -
Mountz Inc.
The torque analyzer is designed for calibrating tools, joint testing, auditing and measuring torque. Torque tools go out of calibration with use. To maintain consistent accuracy, torque tools must be checked periodically for wear or defective parts. A power or hand torque tool is a measuring tool that must be properly calibrated and maintained.