Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 796 - 810 of 1892 items found.

  • Temperature Simulators

    ThermoWorks

    A single select button scrolls quickly between the 3 factory set calibration points for efficiency. Two models to choose from: 271-018 (0°F, 32°F, 212°F) and 271-019 (32°F, 212°F, 500°F). Each unit includes a 3-point UKAS Accredited Calibration Certificate so you know that you''re using a precision instrument. Also included is a 3 foot type K test lead for connecting up your type K meters. You get precision at an economic price. Simple and fast!

  • MPS™ Flammable Gas Sensor

    NevadaNanotech Systems, Inc.

    NevadaNano’s Molecular Property Spectrometer™ (MPS™) Flammable Gas sensor is powering the next generation of combustible gas detection. The MPS delivers unprecedented reliability, accuracy, and worker safety by simultaneously detecting over a dozen of the most common combustible gases, including Hydrogen, Methane, Propane, Butane, and many more. We call this TrueLEL™. No other flammable gas sensor can accurately report 0-100% LEL across over a dozen different gases with just one factory calibration, the MPS never requires field calibration.

  • GRIDSCAN 5000

    Hydrogen Series - H2scan Corp.

    The H2scan GRIDSCAN 5000 Hydrogen Sensor pairs a high performance ASIC to H2scan’s field-proven solid-state hydrogen sensor. This stand-alone sensor system has been designed to provide precision hydrogen measurement, at a lower cost for the high-volume OEM or utilities. No calibrations or maintenance is needed for up to 10 years, and the GRIDSCAN 5000 is the lowest cost by thousands to any other available hydrogen DGA system. H2scan is the only company in the industry that can state retail sales of over 15,000 sensor systems worldwide with no after sale calibrations performed since 2012.

  • PXI RTD Simulator Module 6-Channel PT1000

    40-262-102 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • Pressure Sensors

    ESCP-BMS1 Sensor - ES Systems

    ESCP-BMS1 is an absolute, gauge or differential pressure sensor of ultra-high resolution with analog (0-3,3V), PWM, SPI or I2C interface. The output is fully calibrated, and temperature compensated based on the internal temperature sensor and the factory calibration coefficients which are stored in the embedded memory. The sensor is ready to be installed directly to the end system without further processing with medical, HVAC, industrial, commercial & automotive applications. The total error including repeatability, hysteresis, non-linearity, thermal offset and calibration error between 0°C and 60°C is better than 0.25% FS.

  • PXI RTD Simulator Module 12-Channel PT1000

    40-262-202 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • PXI RTD Simulator Module 18-Channel PT1000

    40-262-002 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • PXI RTD Simulator Module 6-Channel PT100

    40-262-101 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • Analysis Tool for ECU Networks and Distributed Systems

    CANape - Vector Informatik GmbH

    The primary application area of CANape is in optimizing parameterization (calibration) of electronic control units. During a measurement process, you can simultaneously calibrate parameters and record signals. The communication between CANape and the ECUs takes place via protocols such as XCP or via microcontroller-specific interfaces with the VX1000 measurement and calibration hardware. CANape supports various ADAS sensors such as radar, LIDAR and video. Combined with high-performance hardware, CANape can store multiple gigabytes of data per second. Calibration data management and convenient measurement data evaluation including data management as well as reporting make CANape a complete tool for ECU calibration. Of course, CANape also provides access to bus data, diagnostic data and analog measurement data.

  • Thermocouple Calibrator

    Extech PRC20 - Extech Instruments Corporation

    The PRC20 sources and measures eight thermocouple type devices (J, K, T, E, C, R, S and N) and provides precision output displayed as Centigrade/Fahrenheit or mV. It has five user adjustable calibration presets and a Type K temperature range of -58 to 2498 degrees F (-50 to 1370 degrees C). The PRC20 is suitable for Lab and field calibration, Engineering research and design, Manufacturing and test engineering, Temperature control process troubleshooting and HVAC applications. Comes with thermocouple calibration cable with subminiature connectors, standard calibration cable with subminiature connectors, 100V-240V AC universal adaptor with four plugs, six 1.5-volt AA batteries, hard case, and user manual.

  • Four-Wavelength Laser Source

    CA6017 Series - UC Instruments, Corp.

    The CA6017 Can transmit with a wavelength-identification digital encrypted protocol, enabling the FHP2 power meter to automatically use the proper calibration wavelength. This feature reduces the need for communication between the two technicians and decreases the possibility of making mistakes

  • Multilogger

    M1200 - COMET SYSTEM, s.r.o.

    Universal datalogger with 4 inputs for thermocouples K, J, S, B, T, N. Multilogger can be installed permanently to Ethernet network or work as portable device. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

  • Proximity Sensors

    Premier Electrosystems

    Premier Electrosystems is an esteemed name in the manufacturing of inductive proximity switch, photo sensors, capacitive sensors, magnetic sensors, hall effect sensors, analog sensors, encoders, infrared sensors, etc. with NABL calibration certificate

  • RF Capacitance Level Switches

    ABB Ltd.

    ABB's RF Capacitance level switches feature one-step external calibration, immunity to material build-up, and a wide selection of probes for even the most challenging applications from low dielectric bulk solids to sticky slurries.

  • Programmable Gamma For Automotive

    Renesas Electronics Corp.

    Renesas' automotive-grade programmable gamma buffer ICs for infotainment, ADAS and instrument cluster displays deliver the highest accuracy gamma calibration to ensure consistent brightness and color matching of every LCD panel inside a vehicle.

Get Help