Showing results: 901 - 915 of 1892 items found.
-
Krohn-Hite Corporation
Our DC Source/Calibrators are designed for a typical applications such as the design, check and calibration of high speed, high resolution A/D converters; design and certification of high speed data logging and process control systems; calibration of digital voltmeters and multimeters; as an “IMBEDDED STANDARD” and/or simulator; design, testing, simulation and certification of thermocouples, strain gages and transducer instrumentation.
-
6003A -
Fluke Calibration
The Fluke Calibration 6003A Three Phase Electrical Power Calibrator is the most cost-effective way to get the superior accuracy and performance of three independent phases in one instrument. It is an ideal solution for calibration laboratories, electronics manufacturers, electric utility meter shops, and other organizations that manufacture and maintain energy meters, power quality analyzers, and similar tools.
-
Seaward Group USA
The range of resistance decade boxes includes 5, 6 and 8 decade boxes which are designed to provide highly accurate and variable standard values of resistance and current for calibration, comparison and test applications in electrical and electronic workshops, test laboratories and educational environments
-
CNR LOCK -
Com-Ten Industries
CENTOR Manager is a simple, user-friendly utility that enables you to communicate with your CENTOR Easy, Star or Dual memory.It enables you to:– modify the calibration date,– reset the overload counter to zero if the sensor has not been damaged,– block access to the menus and configuration.
-
ION 2700 -
Thermo Scientific
Intuitive, self-diagnostic and flexible with advanced set-up options for user-customization, the Eutech ION 2700 series comes with a large, one-glance-sees-all screen. View pH, ION or Redox reading together with temperature, electrode status, calibration points, date and time all at once!
-
VLSI Standards, Inc.
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
GRL-PCIE3-BASE-RX -
Granite River Labs Inc.
GRL’s PCI Express®3.0 Base Specification Receiver Calibration and Test Automation Software for the Tektronix BERTScope™ BSA (GRL-PCIE3-BASE-RX) provides an automated, simple, and efficient way to test your PCIe 3.0 Receiver to the Base (ASIC) Specification.
-
JETI Technische Instrumente GmbH
JETI offers two model series of spectroradiometers: spectraval and specbos. Both instruments are based on high quality array spectrometers with controlled properties. They are available in different versions (see table below). Additionally, a variety of accessories is available. All calibrations are NIST traceable.
-
Guildline Instruments Ltd
QUANTUM HALL SYSTEM has been developed to meet the needs of Standards Laboratories around the world for an improved level of accuracy in the calibration and maintenance of primary resistance standards. Includes QHR Sample(s), Magnet, Cryogenics and Room Temperature 6622A-QHR Resistance Bridge.
-
SMART Trac II -
CEM Corp.
Direct measurement means delivering the right answer, no matter what; changes in color, additives, temperature, or granularity do not alter the results. Because the moisture and fat are being measured directly, costly maintenance calibrations and are not required for accurate results, saving time and money.
-
Elcometer Limited
Supplied with either standard cables or armoured metal reinforced heavy duty cables, Elcometer convex surface profile probes are supplied with a glass zero tile, calibration test foils (nominal values 125μm (5.0mils) & 508μm (20mils)) and an Elcometer test certificate.
-
E1739A -
Keysight Technologies
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
34308A -
Keysight Technologies
thermistors, epoxy encapsulated with bead construction. The operating temperature range is 0 degrees C to 75 degrees C, with 0.1 degrees C interchangeability. The 34308A is recommended for high accuracy, high sensitivity temperature measurements and for calibration of the Keysight 34970A multiplexer modules.
-
E1739D -
Keysight Technologies
The E1739D 25-meter (82 feet) Sensor Cable is used to connect E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
1251 -
Ballentine Laboratories, Inc.
The BLI Series of Micropotentiometers consist of a Model 1251 terminating resistor and a Model 1351 Thermoelement housing. These micropots are true RMS current to voltage converters for calibrating AC instruments. The NIST calibration range is from dc to 500 MHz (available to 1.2 GHz)