Showing results: 436 - 450 of 1892 items found.
-
CyberScan CON 110 -
Thermo Scientific
Single & Multi-point Automatic or Manual Calibration for quick and easy calibration±1% Full Scale Accuracy for precise and accurate measurements
-
CyberScan Ion 510 -
Thermo Scientific
Low Cost Plus High Performance - offers laboratory-quality readings for a very economical cost :: Multi-Point Push-Button Calibration (up to 3 points) with Auto-Buffer Recognition - choice of USA and NIST pH buffer standards for quick calibration with no calibration mistakes
-
CyberScan pH 510 -
Thermo Scientific
Low Cost Plus High Performance - offers laboratory-quality readings for a very economical cost :: Multi-Point Push-Button Calibration (up to 3 points) with Auto-Buffer Recognition - choice of USA and NIST pH buffer standards for quick calibration with no calibration mistakes
-
Morehouse Instrument Company Inc.
Aircraft and truck scale calibration often requires special adapters to simulate a tire. Scales come in a variety of sizes and have specific tolerances. Many other calibration laboratories do not use the right adapters or consider the impact of the uncertainty of the reference standard used for calibration.
-
Rice Lake Weighing Systems
Say Goodbye to Paper Cal Reports! No more manually creating, printing, storing and retrieving calibration certificates.Using CRS™ calibration and certificate management software, scale technicians performing onsite calibrations enter data directly on their mobile tablet. Customers can access and print their scale calibration certificates online via a password-protected and secure website.Get the power of automated certificate management and gain a competitive edge. Visit www.CertificateRetrievalSystem.com
-
all-sun
is a multifunction calibrator-tester, to be used primarily as a standard for calibration laboratories. It can be used for calibration of any measuring instrument which measures voltage, current, resistance, capacitance and frequency.
-
840A -
TEGAM Inc.
Used by calibration technicians or manufacturing engineers to perform field calibrations on K-J-T thermocouple thermometers. The single input/output meter doubles as a K-J-T thermometer.
-
N2002A -
Keysight Technologies
The N2002A noise source test set is a low cost, stand-alone instrument that, as part of a calibration system, enables fast, repeatable calibrations with minimal levels of uncertainty.
-
WIKA Alexander Wiegand SE & Co. KG
Hand-helds are portable calibration instruments for mobile use for the accurate measurement and recording of temperature profiles. For the instruments there are various designs of thermometers available. Through this, hand-helds are particularly suitable as test instruments for a large variety of applications in the widest range of industries. Data recorded in the hand-held can be evaluated via PC software, some instruments document calibrations in the internal memory, which can later be read on a PC. Optionally, a calibration certificate can be generated with our calibration software WIKA-Cal.
-
Mensor Corp.
Hand-helds are portable calibration instruments for mobile use for the accurate measurement and recording of temperature profiles. For the instruments there are various designs of thermometers available. Through this, hand-helds are particularly suitable as test instruments for a large variety of applications in the widest range of industries. Data recorded in the hand-held can be evaluated via PC software. Some instruments document calibrations in the internal memory, which can later be read on a PC. Optionally, a calibration certificate can be generated with our calibration software WIKA-CAL.
-
M2000/M2001 -
Martel Calibrators
The Lab Calibrator combines the power and features of a voltage/current calibrator, with the addition of thermocouple, RTD, and pressure calibration, for a single laboratory calibration instrument unmatched in versatility, performance, and value.
-
2575A -
Valhalla Scientific Inc.
A versatile, powerful calibration tool, the 2575A Precision AC-DC Active Current Shunt measures both AC/DC current and works as a standard for low-level resistance calibration requirements.
-
IEC61000 -
Newtons4th Ltd
N4L are the only IEC61000 EMC test system manufacturer in the world* with an on site UKAS ISO17025 calibration laboratory offering accreditation to IEC61000-3-2, IEC61000-3-3, IEC61000-4-7 and IEC61000-4-15. Calibration and trace-ability are a vital aspect of any EMC test solution and the coverage provided through N4L’s UKAS Laboratory is comprehensive. N4L’s IEC61000-4-15 calibration procedure is particularly noteworthy as it covers the entire test protocol detailed in Annex C of IEC61000-4-15. It is commonplace for specific parameters within IEC61000-4-15 (d parameters are frequently omitted from calibration procedures) to remain untested during typical flicker calibration due to the difficulty in providing trace-ability for such measurements. All tests within the test protocol of Annex C are included within the scope of accreditation and calibration procedures at N4L.
-
-
CHINO
Standard thermocouples for calibration of thermocouples.