Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
High Temperature, Low Strain Capacitive Extensometers (1200 C or 1600 C)
Model 3648
-
Jinan Testing Equipment IE Corporation
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
-
Product
VXG Vector Signal Generator
M9484C
Vector Signal Generator
The M9484C VXG is the industry’s first vector signal generator capable of generating signals up to 54 GHz with 2.5 GHz of modulation bandwidth per channel. The VXG vector signal generator helps you deliver the next frontier of wireless technology such as 5G and satellite communications with a fully integrated, calibrated, and synchronized solution.
-
Product
AmeTrim
-
AMETEK Sensors, Test & Calibration
Using the external reference sensors on the temperature calibrators or indicators to measure the true temperature, AmeTrim can perform a fully automatic calibration and adjustment of the internal sensor.
-
Product
Analoge Sound Level Meter
Model KM-20/ YF-20
-
Kusam Electrical Industries Limited
One-handed simple, easy to operate. Inbuilt reference signal. Inbuilt battery test. Quickly, accurately sures sound level. Compressed scales minimise range switching. An internal reference signal is available for checking the meter’s operation. Calibration Check. Microphone with Capacitance Microphone.
-
Product
Mass Calibration
-
Trescal provides full Mass Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Mass Calibration services can be delivered at your site or at our lab. Accreditations for our mass calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Waveform Generation Toolbox for Wideband Signal Simulation
N7509A
-
The Waveform Generation Tool provides a simplified interface for baseband modulation of Keysight's wide bandwidth signal simulation solutions, for signals with up to 1 GHz RF bandwidth. Even the most complex signals are defined and implemented easily through the software interface. Signals can be defined through basic parameter entry or from files created in MATLAB or other engineering environments. For each selection in the main menu, a subsequent screen appears, enabling the user to enter the parameters required to define the waveform and invoke the built-in calibration routines. A display on each sub-panel shows the ideal frequency domain waveform calculated from entered parameters. A simulation mode is provided to enable development and operation without connection to the instrument hardware.
-
Product
Mass Flow Controller for Low Flow
HFM-200 / HFC-202
-
The HFM-200/HFC-202 is Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM's for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-200 / HFC-202 meters and controllers have flow ranges from 0-10 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
Product
Spectrophotometer - Spectrometer
-
Spectroscopy has a wide area of application in many fields. Spectroscopy is based on the concept of Energy = frequency x Planck (E=ʎh) constant which is used to study matter. Spectrometry is the technique which is used to analyze the concentration of elements in the sample being tested. Our products are able to analyze carbon, aluminum, sulfur, gold, silver, magnesium, steel, alloys and many other elements. We can also calibrate our products to account for elements like oxygen which are present in many compounds by calibrating with a known sample.
-
Product
Meter Test System
MTS-122
-
Kongter Test & Measurement Co., Limited
This rugged Meter Test System is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 36A). This system is particularly designed with modular structure for calibration and test of analog meter, digital meter, RTU, electrical transducer, energy meter and so on. It is operated under high functionality with user friendly interface.
-
Product
Thermocouple Calibration Furnace
9118A
-
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
Product
Meter with "3-in-1" pH/Temperature Combi Electrode
pH 5+
-
Multi-Point Calibration (up to 5 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
XYZ Color Sensor
AS7261
-
Calibrated XYZ color sensor provides complete, integrated platform for handheld color analyzers, color calibration and mobile analysis devices. Tri-stimulus XYZ realized by silicon interference filters. UART or I²C slave digital Interface. 16-bit ADC with digital access. Programmable LED drivers. 20-pin LGA package 4.5mm x 4.7mm x 2.5mm, with built-in aperture. Compact true-color sensing. Applications; Color/CCT sensing, Fluid or reagent analysis, Color point comparison, Display calibration.
-
Product
Mobile ASA-Livestream Data Node for Main Inspection
CONNECT CUBE V3 | VP 185076
-
Maschinenbau Haldenwang GmbH & Co. KG.
The mobile data node is the right tool for quick and digital diagnosis of the brake system as well as for routine testing and calibration of all ASA livestream-capable brake testers. The plug & play solution can also be used for modern routine testing and calibration of brake test stands.
-
Product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
Temperature Input Module
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
VCOM Amplifiers And Calibrators
-
Renesas offers various VCOM amplifiers including rail-to-rail input-output operational amplifiers and rail-to-rail input-output buffers, as well as programmable VCOM calibrators that are ideal for display applications.
-
Product
Milliamp Calibrators & Loop Calibrators
-
Practical Instrument Electronics, Inc.
PIE has milliamp calibrators to fit your needs from the PIE 334 with the basic functions of a 4-20 milliamp calibrator to the advanced loop troubleshooting capabilities of the Model 532. And PIE milliamp calibrators are the only models with patented Loop Diagnostic Technology! All the loop calibrators have fuse-less protection, rugged design, long battery life. Calibrate in the units matching your instruments by displaying in milliamps and percent (%) of 4 to 20 milliamps.
-
Product
Computer Based Audio Component Test System
DATS V3
-
Rugged aluminum housing with detachable test leads and built-in precision calibration resistorTighter tolerances on internal components for more precise measurementsIncreased output capability means greater separation from the noise floor, resulting in more accurate measurementsDATS Linearity Test for comparing parameters and impedance plots at multiple drive levelsOptional under desk mounting brackets included to save desk spaceOnly 1" H x 2-1/2" W x 4-1/8" D for easy portability
-
Product
Real Time FFT Spectrum Analyzer
-
Fatpigdog's Real Time FFT Spectrum Analyzer software is intended for hobbyist and casual use only. It is not a calibrated software instrument, and therefore any results produced can not and must not be used to provide quantified spectral and power measurements for commercial, medical, military, government, or any other official use.
-
Product
Light Measurement Detectors
-
International Light Technologies
ILT detectors are designed to emit low levels of current in the pico-amp to milli-amp range which is then converted to calibrated optical units such as lux, W, W/cm2, etc., when used with ILT light meters. Detector assemblies typically include a sensor, filter, optic and calibration.
-
Product
Measuring Receivers
-
Calibration and performance check of signal generators and attenuators
-
Product
Aircraft and Truck Scale Calibrator
-
Morehouse Instrument Company Inc.
Aircraft and truck scale calibration often requires special adapters to simulate a tire. Scales come in a variety of sizes and have specific tolerances. Many other calibration laboratories do not use the right adapters or consider the impact of the uncertainty of the reference standard used for calibration.
-
Product
Noise Figure Analysis Using NI PXI RF Test Instruments
NI-RFmx Noise Figure
Test Instrument
Measure noise figure, gain, Y-factor, effective temperatures, hot and cold power, and moreOptimized calibration and measurement routines for multi-DUT test using Y-factor and cold sourceSupports the PXIe-5668R 26.5 GHz VSA, the PXIe-5698 26.5 GHz preamplifier, and VSTsDesigned for use with industry-standard noise sources such as the Noisecom NC346 Series
-
Product
Spectral Irradiance / Illuminance Calibration Standards
-
Standard lamps calibrated in illuminance and spectral irradiance. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Thermocouple Simulator Module for SLSC
Simulator
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
Product
Miniature Concentric Ring Set
PRF-912B
-
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
Product
Broadband Horn Antenna (4GHz - 40GHz (calibrated from 18GHz))
PowerLOG® 40400
-
• Extremely wide frequency range from 4GHz to 40GHz (calibrated from 18GHz to 40GHz) • Supports high input levels up to 300W (peak) or 150W (CW) • High gain up to 17dBi • Delivered including specific calibration data • Perfect for EMC and immunity tests with Spectrum Analyzer.
-
Product
Standard Voltage 78 Pin D-Type Cables - Calibration Cables For Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 78-pin D-type calibration port connector.