Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
Product
Novo-Gloss Trio Glossmeter 20/60/85
-
20/60/85 glossmeter for measuring matt to mirror finishes. Complies to ISO 2813 and ASTM D523. Supplied with 2 year warranty, NIST traceable calibration tile
-
Product
Headlight Testers
-
Devices for the calibration of car lights.We work every day with passion to offer you efficiency and reliability.Each component is assembled by our technicians with the utmost care and expertise.
-
Product
Mass Flow Calibration
-
Allow instrument interchangeability without affecting your process and meet ISO 9001 requirements easily and efficiently with Process Instruments’ Mass Flow Calibration and Repair Services.
-
Product
Calibrators
-
Fluke offers a wide range of pressure calibration tools with precision pressure measurement from 15psi/1 bar to 10,000 psi/690 bar boasting 0.025% full-scale accuracy. Everything from simple test gauges to calibrators with built in electric test pumps. Easy to use, rugged and reliable construction and an industry best 3-year warranty. Fluke means pressure.
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Calibration
-
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
Product
RF Reference Source
96040A Series
-
The 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.
-
Product
Hydrophone
RESON TC 4014
-
The TC4014-5 broad band spherical hydrophone offers a very wide usable frequency range with excellent omnidirectional characteristics in all planes. The overall receiving characteristics makes the TC4014-5 an ideal transducer for making absolute underwater sound measurements up to 480kHz. The wide frequency range also makes the TC4014-5 perfect for calibration purposes, particularly in higher frequencies.
-
Product
Bluetooth® Enabled ORP/REDOX & Temperature Pen
UltrapenX2™ PTBT3
-
*Accuracy of ± 10 mV ORP*3 Calibration Options with Automatic Solution Recognition*Automatic Temperature Compensation in Calibration Mode*99.9% Pure Platinum Electrode*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type Battery (Included)*Waterproof
-
Product
Waterproof pH/mV Meter with ATC Probe
CyberScan pH 610
-
6 calibrations points and 20 auto/manual buffer options sets for quick, convenient calibration.Cal-Due Alarm Prevents Out-dated Calibrations, while Set-Point Alarms warns when readings are outside set-point limits.
-
Product
Wireless Loadlink
-
This wireless load link is designed to be light, accurate and easy to handle. It is supplied with a handheld monitor/indicator unit, calibration certificate, manual and a plastic carrying case.
-
Product
Temperature Sensors
TT420
-
Features• 2-wire, loop-powered 4-20mA analog output• Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner• Compatible with PLCs, meters, and data acquisition systems• No user calibration• TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap• TT420F mounts onto any flat surface• UL listed, Intrinsically Safe (IS)• Class I, (C, D) and Class II, (E, F, G)
-
Product
Industrial Temperature Sensors
-
AMETEK Sensors, Test & Calibration
Temperature measurement and calibration is our specialty, allowing us to provide much more than just standard sensors and assemblies. Our long experience, developing and producing industrial temperature sensors, provides us with a wide knowledge about applications and customer needs. This enables us to build and deliver quick and custom-designed quality temperature sensors for almost any kind of solutions and applications, no matter what industry. We offer a complete range of thermocouple assemblies and resistance thermometers, as well as thermocouple wire, extension wire, temperature transmitters and accessories.
-
Product
PH And Temperature Pen
Ultrapen™ PT2
-
This instrument is designed to be extremely accurate, fast and simple to use in diverse water quality applications. Advanced features include automatic temperature compensation; highly stable microprocessor-based circuitry; user-intuitive design; and waterproof housing. A true one-handed instrument, the PT2 is easy to calibrate and easy to use. To take a measurement, you simply push a button then dip the pen in solution. Results display in seconds.
-
Product
Mobile sound Level Meter
SoundMeter
-
SoundMeter turns your iOS device into a handheld sound level meter (SLM) with support for exponential-time-weighted sound level (Lp) and equivalent sound level (Leq) measurements with various time and frequency weightings. The built-in signal generator tool can be used for generating calibration test tones, noise, chirps, or other periodic signals. SoundMeter also offers additional tools via in-app purchase, including a Noise Dosimeter and a whole or 1/3-octave real-time analyzer.
-
Product
PC/104-based Analog Input, Analog Output, and Digital I/O Board
PCM-MIO-A-1
Digital I/O Board
The PCM-MIO-A-1 is a versatile, PC/104-based analog input, analog output, and digital I/O board designed for high-accuracy and high-channel-count analog and digital I/O. The board is based upon Linear Technology’s precision converters and voltage references which require no external calibration. The digital I/O utilizes WINSYSTEMS’ versatile WS16C48 Universal I/O controller functionality, also available on many of our SBCs and other I/O products.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
Enhanced Time Domain Analysis With TDR
S96011B
-
Use S96011B to perform enhanced time domain analysis for high-speed data applications. Includes all functionality of the S96010B (TDR/TDT mode). In addition, the S96011B enables more detailed measurements and evaluations, such as eye diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S96011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, use mechanical calibration kits or ECal with DC option (i.e. N469xD or N4433D with Option 0DC).
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Retroreflector
10767A
Retroreflector
The Keysight 10767A Linear Retroreflector is one component in a family of measurement optics that tailor interferometer systems for the physical layout and measurement requirements of each application. When configured with appropriate Keysight5530 Laser Calibration System components, 10767A becomes part of a precise positioning system that improves product quality, increases yields, and facilitates the manufacture of precision products.
-
Product
High Speed Data Logger
9330
-
The Model 9330 displays 24-bit resolution and has an impressive 3750Hz update rate. Incorporating peak and valley capture, it can store up to 6 sensor calibrations and measurements from load cells or torque transducers can be logged at 1000Hz to a standard SD card. This data can then be downloaded to a PC via the built-in USB port and Windows compatible software for off-site analysis. Adding further versatility, the rechargeable battery can power up to 4 x 350 ohm sensors, but also offers up to 300 hours stand by time and up to 20 hours continue use.
-
Product
Signal Conditioner
DMA2
-
Din rail mountable with user selectable outputs of +/-10V, +/-5V or 4-20 mA. 10-28VDC powered suitable for battery or automotive use. Features 1000 Hz bandwidth and push-button shunt calibration.
-
Product
Portable heat flux sensor, with read-out unit
HF03 / LI19
-
Hukseflux Thermal Sensors B.V.
The HF03 is a heat flux sensor that can be used in mobile applications. It is combined with LI19, a high accuracy hand-held read-out unit that can be used both for mobile measurements and as an amplifier directly connected to a PC. The combination HF03 / LI19 is typically used to study heat flux levels around flares and fires, and to calibrate flare radiation monitors / flare heat flux sensors.
-
Product
Meter With pH Electrode, Conductivity Probe
PC 2700
-
Your all-in-one solution for multi-parameter research work in the lab! The new PC 2700 is accurate, reliable and intuitive with user-friendly functions. Meter comes with a multi-data screen that includes Temperature, electrode status, calibration points, date and time along with your desired measurement parameter
-
Product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
-
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
Product
Thermometer
C0111
-
Audio and optical alarm of measured temperature. LCD backlight. Minimum/maximum memory. Memory of minimum and maximum temperature included traceable calibration certificate.
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
Optical Power Meter
TL-520
-
TL520 Mini-Designed Optical Power Meter is a self-developed test instrument which is widely used for installation, operation and maintenance of fiber-optic network. TL520 can test optical power within the range of 800~1700nm wave length. There are 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, six calibrated wavelength.





























