Showing results: 766 - 780 of 860 items found.
-
TWA Advanced Series -
Amperis sl
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
TWA Standard Series -
Amperis sl
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
Analog Devices Inc.
Analog Devices’ family of isolated I2C isolators support a complete isolated I2C interface. This portfolio is based on our iCoupler® chip scale transformer technology. iCoupler is a magnetic isolation technology with functional, performance, size, and power consumption advantages compared to optocouplers. By integrating iCoupler channels with semiconductor circuitry, our technology enables a complete, isolated I2C interface with a small form factor. Our I2C isolators covers applications such as central office switching, networking, and power over Ethernet.
-
UL 30 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR UL 30. The UL 30 receiver is used together with a ground microphone (BM 30) and a surge voltage generator (SSG, STG) to pinpoint cable faults. With the coil integrated in the BM 30 for runtime measurement, the device determines the time difference between the magnetic and acoustic signal. This particularly offers special advantages when d ealing with faults difficult to locate acoustically.* Built-in speaker* Splashproof design* Large, illuminated display* Lightweight
-
B-1026 -
ROSS ENGINEERING CORPORATION
Ross Engineering Corporation has developed and manufactures a line of Electrostatic Discharge (ESD) testers. One model is designed for explosive proof testing per MIL-I-23659C, Paragraph 4.4.3.2 static discharge test. It incorporates high voltage electro magnetic or air pressure operated relays to safety ground, charge, and dump capacitors into the appropriate device under test. This ESD tester is a portable system utilizing 120V AC power. It is a high reliability device capable of many thousands of cycles.
-
Rocky Mountain Laboratories, Inc.
Scanning probe microscopy (SPM) refers to a family of measurement techniques that utilize a scanning probe. The most common measurement is Atomic Force Microscopy (AFM Analysis), which measures surface topography. Imaged areas can be from the nm scale to as large as 100 µm X 100 µm. Heights and depths of features can be measuredand many surface roughness parameters, e.g Ra, can be calculated. 3-D images can also be produced for dramatic data presentation. Magnetic and electrical response can also be measured with SPM.
-
Beijing KeHuan Century EMC Technology Co,.LTD
Vehicles are the daily means of transportation for our public, and the electromagnetic pollution in vehicles has received more and more attention from the public. The newly revised mandatory standard GB27630-201X "Air Quality Evaluation Standard for Passenger Cars" intends to require the electromagnetic field in the vehicle as one of the indicators. The measurement method measures the magnetic field strength in the vehicle. Within the frequency range of 10Hz-400kHz, the electromagnetic field measurement results should meet the requirements of the public limit of electromagnetic exposure in GB8702-2014.
-
Elmika
Waveguide cassettes provide easy way for the network analyzer calibration and material properties as dielectric permittivity or (and) magnetic permeability measurements. By changing insertion sections, it is possible to calibrate "Short" and "Thru". Optional cassettes with quarter wave "short" inserters are available. Using this waveguide cassette, it is possible to do vector network analyzer calibration or additional scalar network analyzer calibration. Insertable sample holders supports two measurement methods: the rod in the centre of the waveguide and filled waveguide cross-section.
-
Adamant Namiki Precision Jewel Co Ltd.
There is a structure in the cage shape by only the copper wire turns around a cylindrical permanent magnet placed inside It is a feature. There There is not an anron core, it does not receive the action of the copper basket type rotor is light, the moment of inertia becomes small, so quick response is possible. A Permanent Magnet, There Is No Cogging, That Is, Rotation Is Smooth, And Vibration And Noise Can Be Reduced. - Since Rare Earth Magnets With High Magnetic Properties Are Used And The Rotor Is Formed Only With Coils, The Motor Itself Can Be Made smaller and lighter.
-
HS6-DIFF-1000XMEG-W5 -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
HS6-DIFF-1000XMEGS-W -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
GM1-ST -
Alpha Lab, Inc.
The Model 1-ST measures strength and polarity of magnetic fields up to 19,999.9 gauss. The sensor can easily fit in a .060 inch (1.5 mm) gap and is at the end of a 100 cm flexible cable. The sensor end can be bent if required for a variety of situations. Place the sensor on a magnet face to measure the field. With a resolution of 0.1 gauss, it can measure any tiny variation from magnet to magnet or it can detect if a given magnet has lost even a little strength. Bend the sensor in to a "L" to measure inside a DC solenoid tube. The 5 digit display requires neither auto nor manual range change, making it easier to use than older style 3 or 4 digit meters. Turn on the meter and immediately begin reading fields (updates 4 times per second). There is no setup required, making this the fastest, easiest gaussmeter available.
-
Pulse Electronics
Pulse manufactures a diverse line of outdoor automotive antennas. Our ruggedized, built- to-last antennas cover frequencies 136 MHz to 6 GHz, including GNSS and multi-band antennas. Most antennas are available in a variety of mounting styles including NMO, direct mount, glass, and magnetic mounts, and in many different form factors such as low profile, stealth blade, low profile transit, and whips. Pair your vehicular antenna with our wide variety of high performance, high frequency NMO Mounts making your vehicular installation easier while also insuring the best possible antenna performance. Pulse is a leader in automotive aftermarket antennas and has been a main supplier to large Automotive OEM’s for decades. Find your next automotive antenna and NMO Mount today using the product finder below.
-
136 -
Electronic Specialties Inc.
*Mag Lead features a magnetic disconnect near the test probe end. *Just disconnect the test probe and you can “stick” to any metallic ground or test point. *Quit fumbling with alligator clips that fall off - Mag Lead’s powerfull magnet will hold tight! *This is a time saving tool - if you don’t have to walk to your tool box to retrieve your alligator clips, even on just half the occasions, then you’ve saved time. *Very helpful for automotive reference points and troubleshooting. *Can eliminate the need to hold probes while checking or monitoring a signal. *Two high power, low resistance magnets hold the probe to the lead. *Fits almost all Digital Multimeters and can be used with hand-held scopes too. *Get the Mag Lead, it stays put and won’t fall off, like alligator clips do!
-
FT-7200 -
Ono Sokki
The FT-7200 Advanced Tachometer is an easy-to-use handheld digital tachometer offering high functions and performance. The use of FFT (Fast Fourier Transform) technology enables the FT-7200 to perform frequency analysis of rotation speed by using change of signal in sound, vibration or magnetic flux from rotating machines such as a motor or the like. Selection from 5 kinds of measurement modes allows it to calculate and display rotation speed of any complex waveform signals from a sound level meter or an accelerometer accurately by extracting the exact frequency component.