Correlators
-
Product
NI-9435, ±5 VDC to ±250 VDC/10 VAC to 250 VAC, 4-Channel (Sinking/Sourcing Input), 3 ms C Series Digital Module
779010-01
Digital Module
±5 VDC to ±250 VDC/10 VAC to 250 VAC, 4-Channel (Sinking/Sourcing Input), 3 ms C Series Digital Module - The NI‑9435 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel accepts signals from ±5 VDC to ±250 VDC and 10 VAC to 250 VAC; features transient overvoltage protection between the input channels and earth ground; and has an LED that indicates the status. The NI‑9435 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization when installed in a CompactDAQ chassis.
-
Product
Modulation Distortion Up To 50 GHz
S930705B
-
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Fibre Channel Test & Simulation Interface for PCI Express
PCIe-FC4
-
Avionics Interface Technologies
Half-size four lane PCIe board - Supports Point-to-Point, Switched Fabric, and Arbitrated Loop topologies - Two independent Fibre Channel ports - Two SFP sockets accept fiber or copper transceivers - Each port supports 1, 2, and 4 Gbps speedsComprehensive decoding of FC-1, FC-2, and Upper Layer Protocol (ULP) frames - Full Error Injection and Detection - IRIG-B Time Code Encoder/Decoder for Data Correlation - In-line Port Configuration for Transparent Analyzer - Supports multiple ULPs including FC-AE-ASM, FC-AE-RDMA, FC-AE-1553, and FC-AV - Compatible with AIT’s fcXplorer GUI Bus Analyzer Software
-
Product
PXI-6254, 32 AI (16-Bit, 1 MS/s), 48 DIO, PXI Multifunction I/O Module
779118-01
Multifunction I/O
The PXI-6254 offers analog input, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Analyzer
Nexus8630
-
Highly evolved and automated correlation, pattern recognition, & analytics allow communication service providers visualize and exploit real-time insights about their service and application behaviour across individual interfaces or end-to-end connections
-
Product
Resistance Temperature Detectors
-
Sensors used to measure temperature by correlating the resistance of the RTD element with temperature.
-
Product
PXI-6225, 80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Hybrid, Multifunction I/O Module
779296-01
Multifunction I/O
80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module - The PXI‑6225 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PXI-6280, 16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Hybrid, Multifunction I/O Module
779120-01
Multifunction I/O
16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Multifunction I/O Module—The PXI‑6280 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
ARINC 429 Test And Simulation PCIe Module
PCIe-C429
-
*4, 8, 16 or 32 software programmable TX / RX channels*X4 lane PCI Express host interface*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*Sorting according to SDI field*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
Product
Custom Bench Test
-
TestEdge provides customized bench test. If your device has specialized test requirements, it may be necessary to test your device using specialized bench equipment rather than traditional ATE. In other situations, both ATE and a custom bench setup may be required to fully characterize the device and provide necessary correlation. Finally, it may be useful to create a custom bench setup to facilitate device debug.
-
Product
ARINC 429 Test And Simulation VME Module
VME-429
-
*8, 16, 32 or 64 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*PXI interrupts, star trigger, and PXI clock*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*VXI Plug & Play driver including soft front panel*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
Product
Fibre Channel Test & Simulation Interface for PCI-X
PCI-X-FC4
-
Avionics Interface Technologies
Supports Point-to-Point, Switched Fabric, and Arbitrated Loop topologies - Two independent Fibre Channel ports - Two SFP sockets accept fiber or copper transceivers - Each port supports 1, 2, and 4 Gbps speeds - Comprehensive decoding of FC-1, FC-2, and Upper Layer Protocol (ULP) frames - Full Error Injection and Detection - IRIG-B Time Code Encoder/Decoder for Data Correlation - In-line Port Configuration for Transparent AnalyzerSupports multiple ULPs including FC-AE-ASM, FC-AE-RDMA, FC-AE-1553, and FC-AV - Compatible with AIT’s fcXplorer GUI Bus Analyzer Software
-
Product
PXI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module
779629-01
Multifunction I/O
The PXI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Medium-size Reverberation Chamber
E-Series
-
The E medium-size multicavity Reverberation Chamber Series represents that state-of-the-art in reverberation chamber technology. The E-Series can make single measurements, batch tests, protocols or campaign tests for different frequency bands, different technologies and different channel models, running overnight without human intervention. Embedded frequency-, mode-, source- and platform-stirring in a double-shielded set of cavities allow Passive MIMO (Efficiency, Correlation, Diversity Gain, MIMO Capacity and others), Active MIMO OTA (TRP, TIS, TPUT, MTS, CQI, M2TxDT, RSRP, MCL and others) and Time-Domain MIMO (DL/UL TCP/UDP TPUT, RMS DS, STD, PL, CBW, Mute%, eNodeB, VDT-OTA) measurements up to 8x8 and 8DLCC to be performed for antennas and devices up to 50cm and 50kg ranging from 2G to 4G, covering all available cellular and wireless technologies to date, including wearables devices, sound acoustic mute, WLAN and W-IoT testing. There is no RC in the market more advanced than the E-Series.
-
Product
NI-9423, 24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module
779009-01
Digital Module
24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module - The NI‑9423 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels, can accept up to 30 V discrete logic levels, and has an LED that indicates the status. The NI‑9423 offers isolation between the input and output banks from channel to earth ground. The NI‑9423 is a correlated digital module, so it can perform correlated measurements, triggering, and sychronization when installed in a CompactDAQ chassis.
-
Product
Real-time and Direct Correlative Nanoscopy
LabRAM Soleil Nano
-
Fully integrated system based on our OmegaScope scanning probe microscope and LabRAM Soleil Raman microscope. LabRAM Soleil Nano offers unprecedented capabilities for direct co-localized AFM-Raman and photoluminescence measurements. AFM imaging modes (topographic, electrical, mechanical, etc.) and Raman acquisition can be performed either sequentially or simultaneously at the same location of the sample surface. Optical nano-resolution is also achievable with Tip-Enhanced Raman Spectroscopy and Photoluminescence (TERS/ TEPL). LabRAM Soleil Nano is compatible with the environmental chamber for AFM and Raman measurements in controlled atmosphere and at low temperatures.
-
Product
Modulation Distortion Up To 125 GHz
S930712B
-
S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
PCIe Gen3 High Speed, Compact Camera for Testing
CB013CG-LX-X8G3
-
High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
Product
PCI-6225, 80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device
779295-01
Multifunction I/O
80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device - The PCI‑6225 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
DC - 400 MHz PC-Based Timer Interval Analyzer
-
GuideTech’s GT658PCI is an ultra-fast, high resolution, DC – 400 MHz Time Interval Analyzer (TIA), ideal for most PC-based lab bench (timing) test applications. What makes the GT 658 superior to traditional counters is analogous to the difference between volt meters & digital scopes. While both measure voltage, the scope provides much more information about the dynamics of the signal. This is because our patented TIA substantially increases measurement speed, and the measurements are displayed as afunction of time. All of these features, along with the benefit of ‘continuous time correlation to a common reference between all measurement time stamps,’ enable our TIAs to make measurements that weren’t previously possible with traditional counters.
-
Product
Portable Spectrophotometer
CHECK 3
-
CHECK 3 offers excellent correlation to Datacolor’s world-renowned bench top spectrophotometers. It shares the same high-accuracy SP2000 spectrometer as our reference grade Datacolor 800 benchtop instrument. For each measurement, from vendor to customer and throughout the entire supply chain, you can count on the CHECK3 for highly accurate color data.
-
Product
Pocket Colorimeter Illuminance Meter
HPC-3
-
Shenzhen Chuangxin Instruments Co., Ltd.
● Adopting micro-spectrometer technology which is more accurate than traditional photo-detectors .● Measure chromaticity coordinate temperature, chromaticity coordinate, rending index, color difference, etc● Data hold, save and open-function. Several groups of data can be saved. ● Accuracy of chromaticity coordinates :±0.003(x ,y)● 128*64 LED of graphic interface displaying spectrum wave, chromaticity diagram ● USB interface for PC communication ● Quality Li-Battery for recycled-utilization ● Range of wavelength:380nm-780nm; ● wavelength accuracy:±0.5nm Repeatability:±0.2nm ● Accuracy of chromaticity coordinate:±0.0025, Resolution:0.0001; ● Correlated color temperature:1500-25000K, Accuracy:±3%,Resolution:1K; ● Accuracy of total color difference:within±0.2 (under standard illuminate A); ● Range of Illumination measurement:1.0lx-100klx; ● Accuracy of Illumination measurement:Class 1
-
Product
Modulation Distortion Up To And Beyond 125 GHz
S930713B
-
S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Microscopy Software/Hardware
ZEISS Atlas 5
-
Atlas 5 is your powerful hardware and software package that extends the capacity of your ZEISS scanning electron microscopes (SEM) and ZEISS focused ion beam SEMs (FIB-SEM). Use its efficient navigation and correlation of images from any source, e.g. light- and X-ray microscopes. Take full advantage of high throughput and automated large area imaging. Unique workflows help you to gain a deeper understanding of your sample.
-
Product
PXI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Hybrid, Multifunction I/O Module
779121-01
Multifunction I/O
16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXI‑6281 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PXI-6224, 32 AI (16-Bit, 250 kS/s), 48 DIO, PXI Hybrid, Multifunction I/O Module
779114-01
Multifunction I/O
32 AI (16-Bit, 250 kS/s), 48 DIO, PXI Multifunction I/O Module—The PXI‑6224 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PCIe Gen3 Full HD, High Speed, Compact Camera for Testing
CB019CG-LX-X8G3
-
Full HD, High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
Product
Phase Noise Analyzer
NXA-50
-
This new NXA-50 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 50 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
Systems for Water Leak Detection
-
Here you are getting an overview about our devices for water leak detection. In our portfolio you can find systems for electro-acoustic water leak detection, compact onehand receiver, correlators, stationary noise loggers and a lot more...
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.





























