Correlators
-
product
Thermocouple Probes
sensor that measures temperature. It consists of two different types of metals, joined together at one end. When the junction of the two metals is heated or cooled, a voltage is created that can be correlated back to the temperature.
-
product
Enhanced Analysis Module
DR YIELD software & solutions GmbH
The YieldWatchDog Enhanced Analysis Module (EAM) provides additional options for data visualization and correlation analyses. It transforms your YieldWatchDog client into a fully-functional Yield Management System (YMS).
-
product
Correlative Microscopy
Our modular software platforms enable you to acquire, process and analyze images in multiple dimensions and over various timepoints
-
product
CellTest Multichannel Potentiostat
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
product
Carbon Monoxide Analyzer(CO)
AQMS-400
FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.
-
product
Fluorescence Lifetime Spectrometer
S-FL
The technique of Time Correlated Single Photon Counting (TCSPC) has been developed and introduced more then 25 years ago. The technique is now widely accepted to be the most sensitive fluorescence detection technique with the inherent temporal resolution required for fluorescence decays.
-
product
Smart Factory Solutions
Smart4Metrics Factory 4.0
Teradyne’s Smart4Metrics Factory4.0 solution closely integrates the TestStation in-circuit tester operating conditions, status and health data with existing data collection systems in the factory. By providing a single interface to convey both production data and production tester data, correlation of production results with other equipment or environmental conditions is easily integrated.
-
product
ARINC 429 Test And Simulation PMC Module
PMC-429
*4, 8, 16 or 32 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*PXI interrupts, star trigger, and PXI clock*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Sorting according to SDI field*VXI Plug & Play driver including soft front panel*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
product
Modulation Distortion Up To 90 GHz
S930709B
S930709B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 90 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930709B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Test Receiver
NTR GNSS
Our primary objective is to provide a high performance and fully flexible test receiver for all types of GNSS systems. Thus, the NTR fully supports all existing navigation systems. The signal processing is fully flexible. The high performance correlation engine with up to 80 channels is implemented in a powerful set of FPGAs. Signal acquisition and tracking are realized on a high performance embedded ARM Cortex A8.Supporting up to 4 L-band frequencies in parallel, the NTR GNSS test receiver supports all current GNSS transmission frequencies. Due to its plug-in design, the RF front-end can easily be customized for special filtering and other frequencies.
-
product
Security intelligence & analytics
Detect and prioritize threats that pose the greatest risk. dentify high-risk threats with near real-time correlation and behavioral anomaly detection. Detect vulnerabilities, manage risks and identify high-priority incidents among billions of data points.Gain full visibility into network, application and user activity.
-
product
Dual Port Simulator Fiber Channel XMC Module
XMC-FC4 Simulyzer
*Two independent fiber channel ports*The two SFPs accept electrical as well as optical transceivers*Each port supports 1, 2, or 4 Gbps*Supports customer-specific defined transmission speed*Comprehensive decoding of FC-1, FC-2 and Upper Layer Protocol (ULP) frames*Triggering and filtering*Supports DMA for high-speed streaming*IRIG-B time code encoder / decoder for data correlation*Supports ULPs such as FC-AE-ASM, FC-AE-RDMA, FC-AE-1553 and FC-AV*Supports HS-1760E applications such as AS5653, AS5652 and AS5627*Optional fcXplorer, Windows-based FC simulation and analysis test software*FC SDK (Software Development Kit) provides drivers and APIs for Windows XP / 7,*Linux, VxWorks, QNX Neutrino RTOS and others on request
-
product
PCI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO PCI Multifunction I/O Device
779068-01
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO PCI Multifunction I/O Device - The PCI-6229 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
ARINC 429 PMC Interface Module
PMC-429
Avionics Interface Technologies
4, 8, 16, or 32 Software Programmable Tx/Rx ChannelsProgrammable High/Low Speed Operation - Concurrent operation of all Tx/Rx Channels at high data rates - Conduction-cooling and/or conformal coating available - Designed for extended temperature operations - Rate-oriented Label Transmission - Label Selective Trigger for Capture/Filtering - IRIG-B Time Code Encoder/Decoder for Data Correlation - ANSI Application Interface supporting C++, C#, and .net DevelopmentDevice Driver Support: Windows, Linux, VxWorks, and other operating system - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software
-
product
Nanomechanical Instruments For SEM/TEM
As the world leader in nanomechanical testing systems, Bruker makes it easy for you to conduct in-situ mechanical experiments in your microscope with the Hysitron PI Series PicoIndenters. Our unique transducer design delivers unmatched stability throughout your experiments, resulting in precise data even at the nanoscale. Video capture from the microscope enables real-time monitoring and direct correlation of mechanical data to microscope imaging. With solutions designed to fit many of the microscope brands in use, you are sure to find one that is ideally suited to your research.
-
product
Motadata ServiceOps
Problem Management
Motadata ServiceOps ITSM platform’s Problem Management solution manages the complete lifecycle of problems faced by different organizations and helps to diagnose and identify the root cause of incidents. The problem management system prevents problems and resulting incidents from happening, eliminates recurring incidents and minimizes the impact of incidents that cannot be prevented with incident management. With Motadata problem management tool, you can easily correlate incident tickets with a problem. The correlated incidents have a distinctive tag to highlight the relationship.
-
product
Oil In Water/Soil Analyzer
InfraCal 2 ATR-SP
The InfraCal Model ATR-SP is recommended for measuring oil in water, TPH in soil or FOG in wastewater concentration levels when using hexane, pentane or Vertrel MCA as the extracting solvent. Measurement data obtained with this analyzer will correlate to EPA Method 1664 as both procedures are based on evaporation techniques and measuring the residual oil and grease. The analyzer is equipped with a built-in cubic zirconia horizontal attenuated total reflection (HATR) stainless steel sample stage. The InfraCal 2 ATR-SP is a direct replacement for the original InfraCal HATR-T2 used worldwide for the determination of TOG/TPH in water and soil.
-
product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196C
The 16196C surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
product
Dielectric Loss Tangent and Transmission Attenuation Measurement System
RTS03
RTS03 measures relative permittivity (dielectric constant), dielectric loss tangent in the frequency range between 5GHz and 26.5GHz based on a correlation between measurement frequency and transmission attenuation as the microwave passes through the flat plane sample.
-
product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
product
Fibre Channel Test & Simulation Interface for PCI-X
PCI-X-FC4
Avionics Interface Technologies
Supports Point-to-Point, Switched Fabric, and Arbitrated Loop topologies - Two independent Fibre Channel ports - Two SFP sockets accept fiber or copper transceivers - Each port supports 1, 2, and 4 Gbps speeds - Comprehensive decoding of FC-1, FC-2, and Upper Layer Protocol (ULP) frames - Full Error Injection and Detection - IRIG-B Time Code Encoder/Decoder for Data Correlation - In-line Port Configuration for Transparent AnalyzerSupports multiple ULPs including FC-AE-ASM, FC-AE-RDMA, FC-AE-1553, and FC-AV - Compatible with AIT’s fcXplorer GUI Bus Analyzer Software
-
product
Carbon Compound Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
product
High-Speed Digital Image Correlation System
Q-450
The 3D High-Speed Image Correlation System Q-450 allows the full-field, non-contact and three-dimensional dynamic measurement of shape, displacements and strains on components and structures made from almost any material. Based on the digital image correlation technique, the Q-450 system is designed for full-field vibration analysis and high speed transient events. This makes it ideal for ballistics testing, fracture mechanics, shock excitations, the Hopkinson Bar test, or Impact Testing.
-
product
PCI-6255, 80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO PCI Multifunction I/O Device
779546-01
80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO PCI Multifunction I/O Device - The PCI‑6255 offers analog I/O, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
PXI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module
779629-01
The PXI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Phase Noise Analyzer
NXA-26
This new NXA-26 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 26.5 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range. The NXA-26 combines over 25 years of Phase Noise Measurement Technology with an easy to navigate user interface. System operation requires minimal training that will have you making measurements in minutes.
-
product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Modulation Distortion Up To And Beyond 125 GHz
S930713B
S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Gas Filter Correlation Carbon Monoxide Analyzer
Model T300
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Signal Analysis
Synchronous Accumulation (Order Analysis)
Order analysis is one of the most convenient and efficient methods for diagnostics and balancing of rotating mechanisms and transmission gears. With an RPM sensor and a vibration sensor, it is possible to study the time characteristics of gear vibration signals. It is a well-known fact that a signal from a vibration sensor is affected by signals from other sources. To tune out from the disturbing signals, the synchronous signal accumulation method is used. For each shaft rotation, the RPM sensor provides a rotation mark. This signal serves as a triggering strobe for the vibration sensor signal sweeping. The obtained signal sweeps are combined. All the sources of the signals related to the shaft frequency (frequency of rotation) are accumulated and increased in the accumulator linearly proportionally to the N number of rotations. All other signals that are not correlated with the shaft frequency are accumulated proportionally to N1/2 and in case of a greater number of averagings, the useful signal exceeds the interference level.