Transformer Oil
See Also: Oil Dielectric Test Set
-
Product
Current Transformers
-
National Meter Industries Inc.
Is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current (under normal conditions of operation) and differs from it by an angle that is approximately zero.
-
Product
Oil Breakdown Voltage Tester
DTA 100 C
-
Insulating oil testing with the BAUR DTA 100 C. The BAUR DTA 100 C oil tester is designed for continuous operation in the laboratory and is characterised by the combination of extraordinary features. As a high-performance device with a test voltage up to 100 kV, with clear breakdown detection and absolutely reliable measurement results even across several measurement sequences, the BAUR DTA 100 C is the leading testing device for users in the electricity and other industries and in testing institutes.
-
Product
Transform Imagery into Geospatial Understanding
Feature Analyst™
-
Textron Systems' Feature Analyst is tightly integrated with the Esri® ArcGIS® platform to extract feature data from imagery in order to populate geographic information systems (GIS) databases. Analysts can rapidly and accurately collect vector feature data from high-resolution satellite and aerial imagery in order to gain spatial understanding.
-
Product
Oil Content Analyzer
OCMA-550
-
OCMA-550 to measure residual oil on components and concentrations of oil adhered on solids such as soil.Measurement can be easily made only by injecting the extracted water sample into the attached cell and setting it to the equipment.This model features a simple design which allows opening/closing of the door to setting of cell with just one hand.This is best for measurement of extracted samples such as evaluation of residual oil on components and measurement of oil contained in food.
-
Product
Rectifier Transformers
-
Osborne’s Rectifier Transformers are used in conjunction with various rectification configurations to convert AC input to DC output(s). Key characteristics include regulation, transformer utilization and AC ripple. Osborne rectifier transformer designs are often engineered to operate in advanced rectifier circuit applications.
-
Product
Moisture in Oil Transmitter
KT-200
-
Kongter Test & Measurement Co., Limited
KT-200 is a fast, reliable and accurate online transmitter for water activity (aw) in oil and temperature (T). It is very suitable for integration in OEM application with its rugged housing and excellent performance.KT-200 is ideal for online monitoring of moisture in lubrication, hydraulic or insulation oil, which is significant for the long-term performance and preventive maintenance of plant and machinery.
-
Product
Automatic Transformer Test System
TH2829AX-24
-
Changzhou Tonghui Electronic Co., Ltd.
Number of Test PIN: 24 ■ Frequency: 20Hz-200kHz, Resolution: 0.5mHz ■ Signal Level: 5mV-2Vrms(Option:2mV-10Vrms) ■ Test Speed: max. 13ms ■ 7-inch TFT LCD display with a resolution of 800×RGB×480
-
Product
Transformer Turns Ratio Tester
CX-BY
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer.
-
Product
Auxiliary Current Transformers
-
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
Product
Distribution Transformer Tester
NDB-DOC™
-
The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
Product
Transformer Turns Ratio Meter
TTRM 102
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Automatic Transformer Test System
TH2840AX
-
Changzhou Tonghui Electronic Co., Ltd.
■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file
-
Product
Transformer Tester
-
Delta United Instrument Co., Ltd.
Designed for comprehensive testing, including winding resistance, turns ratio, and inductance.
-
Product
Transformer Preamplifier
SR554
-
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
Product
Transformer Ratio Meters
-
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
Product
Transformer Capacity Tester
-
Weshine Electric Manufacturing Co., Ltd
In many industries, including health care, manufacturing, electrical contracting, higher education and corrections, reliable, high-quality transformers are essential for keeping operations running efficiently. Large facilities and industrial processes require substantial amounts of power, and they need dependable transformers to convert the energy coming from the power plant into a form they can use for their equipment and building utilities.
-
Product
Power Transformer
-
Transformer turn ratio meter is special designed for power transformer (single phase & three phases) and instrument transformer testing, suitable for testing in substation, transformer manufacturer, meter manufacturer. It helps to detect faulty transformer winding and tap changer position. It’s fully automatic device, can recognizes winding connection and vector group number of transformer winding. The user only need connect measuring cable and press start button and come out the test result.
-
Product
Oil Breakdown Voltage Tester
-
A specialized device used to measure the dielectric strength of insulating oils until it becomes conductive.
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Transformer Testing
-
The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.
-
Product
Loss Tangent M in Dielectric Oil
TAND220A
-
The measuring instrument type TAND220A complies with the international standard IEC 61620. The instrument is based on the so-called "low-amplitude, low-frequency alternating current square wave method" and allows accurate measurements of conductivity and relative permittivity. Conductivity measurement in the range of 0.01 pS/m to 20,000 pS/m allows the use of this instrument for quality control of high resistivity liquids even at room temperature. The TAND220A works with a low test voltage and also with a low test current so that it does not represent a danger for the operators.
-
Product
Voltage Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Are a parallel-connected type of instrument transformer. They are designed to present a negligible load to the supply being measured and have an accurate voltage ratio and phase relationship to enable accurate secondary connected metering.
-
Product
Complete Transformer Test Bench
-
Weshine Electric Manufacturing Co., Ltd
Our multifunction Transformer Test Bench (VS-ZHSY Series) is intuitive with all of the ease of working with individual, dedicated instruments. We deliver this experience through our design philosophy. Rather than producing a single, complex system with afterthought towards rendering it friendly, we uniquely combine several intelligent instruments packaged as a single system.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Oil Acidity Tester
-
Weshine Electric Manufacturing Co., Ltd
Automatically complete the operations of extractant addition, neutralization titration and end point discrimination, acid value calculation, data storage and print output.
-
Product
Transformer Turn Ratio Tester
KVBB-II
-
KV Hipot Power Test Equipment Co.,Ltd
KVBB-II Transformer turn ratio tester is used to check turn ratio of transformer, tap switch situation, whether transformer interturn is short circuit and transformer can run in parallel or not.
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.