Transformer Oil
See Also: Oil Dielectric Test Set
-
Product
Transformer Turn Ratio Tester
KVBB-II
-
KV Hipot Power Test Equipment Co.,Ltd
KVBB-II Transformer turn ratio tester is used to check turn ratio of transformer, tap switch situation, whether transformer interturn is short circuit and transformer can run in parallel or not.
-
Product
Oil in Water/Soil Analyzers
-
Oil in Water/Soil Analyzers simplify and streamline the on-site oil analysis process, so high-quality information and actionable intelligence leads to effective decision making.SPECTRO's Enterprise Fluid Intelligence offers two key product types: TruVu 360 and Online Training.
-
Product
ANSI Metering Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Transformer Rated Metering Site Training Bench
Model 8833
-
The PowerMaster® 8813 is a true 3-phase training simulator for metering technicians to help improve their troubleshooting skills for applications encountered in the field. The Model 8813 provides a safe, controlled environment to help the trainee accelerate their education in meter testing and wiring verification. The training simulator also features the ability to simulate over 28 commonly found metering errors in the field. Paired with the Training Administrator Station (TAS), the bench can be controlled remotely over a closed WIFI network, and each trainee’s performance is recorded and time stamped for every session.
-
Product
Power Transformer Monitoring
-
Optimize the efficiency of your transformers by relying on our flagship DGA monitoring system with long-term stability, no maintenance needs, no false alarms and a revolutionary method for detecting ambient air ingress.
-
Product
Step Up Transformer
MagD
-
SCOPE proudly introduces Step-Up Transformer - MagD, specially designed to cater the needs of testing of instrument Transformers. Before new systems are put into service or after any occurrence of fault, the instrument transformers need to be tested for their outputs. It is to be ensured that these instrument transformers are giving proper outputs to the protective relays. MagD is used to plot excitation curves for instrument transformers. Inbuilt voltmeter and ammeter, eliminates the need of external meters for plotting of curves. It can also be used for de-magnetization of transformer cores and also turns-ratio tests can be conducted using MagD.
-
Product
Cooking Oil Analyzer
-
Chongqing TOP Oil Purifier Co., LTD
Cooking Oil Analyzer by Chongqing TOP
-
Product
Transformer Loss Measurement Systems
-
Measurements International Ltd.
The Transformer Loss Measuring System stands as a pivotal tool in ensuring the quality assessment of transformers. It plays a vital role in accurately measuring and evaluating the transformer’s performance by assessing both its no-load loss and load loss. Understanding these losses is essential in determining the efficiency and overall quality of the transformer, offering valuable insights for maintenance and improvement strategies.
-
Product
Automatic Instrument Transformer Test Set
-
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
Product
Transformer Ratio Meters / TRM-101
TRM-101
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Produces the 3-ph or 2-ph standard power with stable voltage and phase. Fully automatic: No manual balancing
-
Product
Potential Transformer Test Set
-
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
Product
Single Phase Transformer Ratio Meter
-
*Ideal for VT testing*Bushing Current Transformers (BCTs)*Higher resolution*Excitation current meter
-
Product
COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)
CVCT-S20
-
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.
-
Product
High-Speed Transformer Test System
DU-7211
-
Delta United Instrument Co., Ltd.
Inductance, Q factor, Leakage Inductance, AC Resistance, Capacitance, DC Resistance, Balance,Turn ratio, Open/Short check
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
Product
Clamp Meters / Clamp Current Transformers
Multi-meter clamps
-
Professional electrical testing tools and accessories used to measure AC or DC current safely without disconnecting the live wire.
-
Product
Automatic Three Phase Transformer Ratio Meter
ATRM PLUS
-
*Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.
-
Product
Transformer & Capacitor Testers
-
*Quick and easy check for opens or shorts on transformers before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers*Tests the primary and secondary sides of de‑energized transformers without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer*Automatic self-test feature*Magnet holds the tester in place while testing
-
Product
DC Immune Current Transformer
DCT 108
-
SHANGHAI POWOO INDUSTRY CO., LTD
- Accurate DC measurement; comply to IEC 1036 and IEC 62053; - suitable for a wide range of current (from 1.5A to 100A); - linear output current, high precision; - compact, delicate appearance.
-
Product
XDSL Transformers
-
We manufacture and supply an extensive line of high-performance xDSL transformers, including ADSL, VDSL, Vectored VDSL, VDSL Hybrid, VDSL Line, G.fast, HDSL2 and G.SHDSL transformer and chipsets.
-
Product
Rectifier Transformers
-
Osborne’s Rectifier Transformers are used in conjunction with various rectification configurations to convert AC input to DC output(s). Key characteristics include regulation, transformer utilization and AC ripple. Osborne rectifier transformer designs are often engineered to operate in advanced rectifier circuit applications.
-
Product
Multiplexer For Transformer Testing
MUX-R
-
Raytech Multiplexer MUX R is designed to drastically reduce cabling time and increase test performance. It is made to be used with Raytech Winding Resistance and Turns Ratio Meters. Any MUX R configuration can be easily controlled by a Winding Resistance Meter touch panel or by remote.
-
Product
GDGS Transformer Power Factor And Tan Delta Tester
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester
-
Product
Insulation Oil BDV Tester
-
Wuhan Fanke Transformer Manufacture Co., LTD
Insulation Oil BDV Tester
-
Product
2 Channels, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTB
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
AC Test Transformer
-
Shanghai Guantu Technology Co., Ltd.
How the AC test transformer prevents the overvoltage generated by the frequency conversion series resonance test device is a relatively simple problem, but the overvoltage caused by voltage fluctuation is difficult to appear when the overvoltage protection is set. Generally, the overvoltage of the frequency conversion series resonance test device will appear in the frequency sweep stage of the instrument, that is, in the process of finding the resonance point. Those who have used it know that in the process of finding the resonance point of the frequency conversion series resonance test device, the voltage and frequency have a parabola-like linear relationship. By default, the system finds the high voltage, that is, the apex of the parabola as the resonance point.
-
Product
Burn Down Transformer
ATG 6000
-
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level