Transformer Oil
See Also: Oil Dielectric Test Set
-
Product
1 Channel, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTA
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Transformer Ratio Meters
Three Phase Transformer Ratio Meter Standard Series
-
TRT is based on state-of-the-art technology, using the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
Product
Transformer Ratio Meters
-
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
Product
Insulating Oil Dielectric Loss Tester
HDLT
-
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
Product
Transformer Winding Resistance Testers / TRT ? 27
TRT-27 series
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 2.5A to 20A, Digital display of resistance and test current.
-
Product
Transformer Winding Resistance Testers / TRT ? 2
TRT-2
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 0.02A to 2A DC, Digital display of resistance and test current.
-
Product
Fourier Transform Optical Spectrum Analyzer, 600 - 1700 nm
OSA202C
-
Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.
-
Product
G.fast Transformers
-
Our line of G.fast transformers are the preferred choice of engineers seeking the most reliable, functional isolation transformers for G.fast transmission. These compact transformers deliver excellent longitudinal balance and total harmonic distortion performance.
-
Product
Transformer Ratio Meters / TRM-101
TRM-101
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Produces the 3-ph or 2-ph standard power with stable voltage and phase. Fully automatic: No manual balancing
-
Product
Software For Transformer Measuring Professional
T-Base Pro
-
T-Base Pro is a new powerful software for electrical testing, developed by Raytech GmbH. Years of experience in building world-class testing equipment flowed into the development, resulting in a state-of-the-art software framework. Its functionality ranges from simple data import and export using a USB stick, to the full control of the sophisticated Raytech testing devices and measurement systems remotely.
-
Product
Transformer Turns Ratio Meter
TTRM 101
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Portable Power Source - Power Transformer and Charger Manufacturer
-
JYUE LII INTERNATIONAL CO., LTD.
A&V power transformer supplies and manufactures certified portable power source and charger with industrial UL / cULus / CB / CE / TUV & ISO 9001:14001 certified electrical products and manufacturing facilities based in Taiwan. Portable Power Source Includes C Series, H Series, J Series, L Series, M Series, P Series, Q Series, W Series, Power Bank Series Portable Power Source
-
Product
Power Transformers
-
Power Transformers are used to convert voltages and isolate signals for functionality and safety. Our broad line of catalog and custom solutions range from mW to 5-10kW and are used in multiple topologies including flyback, forward, push-pull, resonant, LLC and phase shifted full bridges. Typical operating frequencies are between 80-500kHz but solutions can be adapted for greater than 1MHz operation.
-
Product
Current Transformer
ST-9RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
Product
XDSL Transformers
-
We manufacture and supply an extensive line of high-performance xDSL transformers, including ADSL, VDSL, Vectored VDSL, VDSL Hybrid, VDSL Line, G.fast, HDSL2 and G.SHDSL transformer and chipsets.
-
Product
Automatic Instrument Transformer Test Set
-
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
Product
Isolation Transformers 230V
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
Product
Handheld Infrared Oil Analyzer
FluidScan® 1000 Series
-
The FluidScan® 1000 series handheld Infrared oil analyzer provides direct quantitative measurement of a lubricant’s condition and plays an important role in Machine Condition Monitoring (MCM) for proactive and predictive maintenance in Reliability Management programs. It determines when oil needs to be serviced due to degradation of the oil chemistry or contamination by other fluids such as water or the wrong oil. It is compliant with ASTM D7889 “Standard Test Method for Field Determination of In-Service Fluid Properties Using IR Spectroscopy”.
-
Product
2 Channels, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTB
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Split type AC Current Transformer
CTF-100T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
Product
Transformers & Reactors
-
Our company leads the market by manufacturing and exporting a wide range of Transformers & Reactors. We manufacture these equipments in different models and technical specifications to suit clients' demands. Our highly skilled team use best grade raw materials and components to manufacture these Transformers & Reactors. We offer these equipments to clients at competitive prices.
-
Product
Split Core Current Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
Product
Distribution Transformer Tester
NDB-DOC-3™
-
The NDB-DOC-3™ is a test instrument designed for distribution networks transformers from 5kVA to 3MVA. It can determine the presence of short circuits or open circuits in the distribution transformer primary winding & also short circuits on the secondary winding.The NDB-DOC-3™ is designed to be operated without disconnecting the transformer’s secondary windings from their loads.
-
Product
Electric Insulating Oil Tester
PortaTest
-
Portatesters are easy to use. Based on the test standard, you select the corresponding test sequence. Then, the required test probe and the electrode gap for the selected test standard is displayed. The setting gauge, included in the scope of delivery, facilitates the adjustment of the electrode gap. Afterwards you fill the insulating oil in the test vessel and close the test chamber.
-
Product
Transformer Testing Panel
VTTP
-
Capable to Test Up to 25 MVA (Other Ranges are Available On Request). Useful for No Load Test (O.C.), Load Test (S.C.), DVDF Test HV Test of Transformer. Mains indication by R,Y,B indication Lamp. Over voltage, over current protection.
-
Product
Power Transformer Testing
-
HAOMAI Electric Test Equipment Co., Ltd.
Testing products for power transformers.
-
Product
Transform Imagery into Geospatial Understanding
Feature Analyst™
-
Textron Systems' Feature Analyst is tightly integrated with the Esri® ArcGIS® platform to extract feature data from imagery in order to populate geographic information systems (GIS) databases. Analysts can rapidly and accurately collect vector feature data from high-resolution satellite and aerial imagery in order to gain spatial understanding.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Fully Automatic Transformer Winding Resistance Tester
-
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.