Transformer Oil
See Also: Oil Dielectric Test Set
-
Product
Multiple Gas Transformer DGA
MULTITRANS
-
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
Product
True Online UPS Systems with Inbuilt Isolation Transformer
-
Our software and connectivity devices incorporate all the features you need to proactively manage your systems, from basic monitoring and shutdown to predictive analysis and power management. Aplab Integration Services offer complete solutions tailored for the specific requirements of Defense Services, Telecom and Commercial markets.
-
Product
Adjustable Isolating Transformers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).
-
Product
2KVA Scaler Transformer
T-1005
-
The Titan Series T-1005 Scaler Transformer is used to conveniently scale the standard OV to 130V/260V full scale AC Power Source/Frequency Converter output to 76 different full scale voltages and currents. It is also used to join and scale the power from multiple Titan series AC Power Sources/Frequency Converters into a single output. It has a conservative continuous power rating of 2KVA and excellent voltage regulation.
-
Product
Transformer Turns Ratio Meters
-
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
Product
Auto Transformers
-
Variac Auto Transformers are continuously variable voltage auto transformer, having a movable carbon tip, fixed to a brush-arm sliding on a silver plated commutator. Rotation of the brush-arm by either manual or motor drive, delivers-an output voltage from zero to or above line voltage.
-
Product
TAN-DELTA AND RESISTIVITY TEST FOR INSULATING OIL
-
International Biological Laboratories
TDRNT02 measures dielectric parameters like D.C. resistivity, dielectric constant and loss factor of the insulating oil of transformers, circuit breakers etc.
-
Product
Transformer Winding Resistance Meters
-
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
Product
Insulating Oil Tester / uP Operated
CU Series
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fully automatic test cycle. Automatic change of sample number of test. Automatic calendar and time running even with power off.
-
Product
HDBaseT Transformers
-
Pulse HDBaseT transformers are designed to provide common mode noise reduction for improved EMI performance and support power over HDBaseT (PoH) applications of up to 100W. The HDBaseT technology enables 5Play feature set, which includes ultra high definition 4K video, audio, 100BASE-TX Ethernet, various control signals, and up to 100W of power, on a single 100m/328ft CAT5e/6 cable.
-
Product
Insulating Oil Testing
-
Insulating materials are the elixir of life of electrical equipment. These materials lose their insulating and cooling properties due to impuri ties and ageing. This damages equipment, causes failures and is consequently often accompanied by high costs. Precise and reliable measurement results.
-
Product
Transformer Turns Ratio Meter
TTRM 102
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Current Transformer
ST-60CT
-
Standard Electric Works Co., Ltd
● 400/5A - 800/5A● 7.5-10V A● Class 1● Insulation 600V
-
Product
Oil Breakdown Voltage Tester
DPA 75 C
-
Insulating oil testing with the BAUR DPA 75C. The BAUR DPA 75C oil tester developed especially for mobile use in the field is one of its kind in the market due to its functionality and excellent user benefits in comparison to the costs. The BAUR DPA 75C delivers clear and reliable measurement results.
-
Product
Oil in Water Analyzers
-
Teledyne Analytical Instruments
Oil in Water Analyzers by Teledyne Analytical Instruments
-
Product
Transformer Testing
-
Haomai Electric Power Automation Co.,Ltd.
1)Test Standard:IEC60076 & IEEE C57.12.90 2)Voltage ratio measurement of transformer 3)Turns ratio measurement of transformer 4)Group vector measurement of transformer
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Rectifier Transformers
-
Osborne’s Rectifier Transformers are used in conjunction with various rectification configurations to convert AC input to DC output(s). Key characteristics include regulation, transformer utilization and AC ripple. Osborne rectifier transformer designs are often engineered to operate in advanced rectifier circuit applications.
-
Product
Transformer Resistance Testing
-
Weshine Electric Manufacturing Co., Ltd
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the WESHINE Transformer Ohmmeter (VS-3110 series) of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
Product
Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm
OSA201C
-
Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.
-
Product
Systems for Oil Quality Monitoring
-
*Reliable monitoring of oil contamination*Reliable machine and plant protection by permanent oil moisture monitoring
-
Product
Oil Content Analyzer
OCMA-500
-
OCMA-500 to measure concentration of oil contained in drainage and environmental water.After injecting the water sample and solvent, all you have to do is press the start button,and the system will automatically conduct the monitoring operation from oil extraction to sample measurement and draining. With no more troublesome operations like opening/closing the drainage valve, monitoring is speeded up.In addition, the color graphic LCD and the backlit extraction tank have improved operability.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Automatic Transmission & Engine Oil Pressure Tester
34500
-
Check oil pressure in automotive transmissions and engines. Adapters provide coverage of most domestic and imported cars and light trucks. Gage calibrated from 0-600 PSI (0-4,000 kPa & 0-7.0 BAR). Includes 6 feet of oil proof hose and 10 assorted fittings. Supplied with instructions in a durable vinyl pouch.
-
Product
Handheld Infrared Oil Analyzer
FluidScan® 1000 Series
-
The FluidScan® 1000 series handheld Infrared oil analyzer provides direct quantitative measurement of a lubricant’s condition and plays an important role in Machine Condition Monitoring (MCM) for proactive and predictive maintenance in Reliability Management programs. It determines when oil needs to be serviced due to degradation of the oil chemistry or contamination by other fluids such as water or the wrong oil. It is compliant with ASTM D7889 “Standard Test Method for Field Determination of In-Service Fluid Properties Using IR Spectroscopy”.
-
Product
Transformer Regulation
-
Transformer Parallel Control System is designed to monitor & control the tap changers of up to four (4) transformers connected on a common bus & operating in a MASTER FOLLOWER control configuration.
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
Instruments Transformers Tester
Calport 100 Plus
-
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
Product
Transformer Turns Ratio Tester
CXBC-901
-
Shenzhen Chuangxin Instruments Co., Ltd.
Transformer Turns Ration Tester is applied to measure the voltage ratio and group testing of the three or single phase transformer. All the test results could be printed by the micro printer or saved in the tester.
-
Product
200KHz AUTOMATIC TRANSFORMER TEST SYSTEM
VE2729XAU
-
Its a Microprocessor Based 200KHz Automatic Transformer Tester with inbuilt 20 Pin Channel Scanner for Automatic Switching and Testing Coils & Transformers (Ferrite) with Max. 20 PINS. Test Parameters : -> Inductance (L)-> Leakage Inductance (Lk)-> Capacitance (C)-> DC Resistance (Rdc)-> AC Resistance (Rac)-> Turns Ratio with Winding Polaity-> Quality Factor (Q)-> Impedance (Z)





























