Showing results: 106 - 120 of 223 items found.
-
PC104 -
Computer Conversions Corporation
The PC104-DS Series are Low Cost, Dual Channel, PC104 Compliant Digital / Synchro / Resolver Output Cards designed to simulate precision AC Synchro and resolver formatted signals for use in navigation and positioning systems or test sets on both industrial and COTS - military type applications.
-
Keysight Technologies
Keysight Attenuators offer a compact, rugged design with exceptionally low insertion loss. Our latest design evolution sets new standards for size and performance. Keysight Attenuators provide excellent repeatability and safeguard your test platform from failures, downtime, and lost production. Discover which of our Attenuators best suits your test and measurement needs.
-
Keystone Compliance
Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to dust. These tests are numbered IP5X and IP6X. The first digit, in the case of dust protected, would always be a 5, and in the case of dust tight, would always be a 6. The first digit, represented by the “X”, ranges from 0 to 9 and specifies the protection from liquid.
-
FPA Series -
High Voltage Inc.
FPA Series test sets perform field or factory testing on larger electrical apparatus, including motors & generators, switchgear, bushings, bus duct, etc. This series offers the higher kVA ratings needed (0-6/12 kV AC @ 6 kVA), but is still packaged for portability.
-
Chroma ATE Inc.
AC power source 61500 series sets up the new standard for high performance AC power source. It equips with all powerful features such as power line disturbance (PLD) simulation, programmable output impedance, comprehensive measurement functions, wave-shape synthesis and regulation test software.
-
DU3328 -
Delta United Instrument Co., Ltd.
Programmable test voltage in AC: 0.1K~5KV, DC: 0.1K~6KV Programmable cutting current in AC:0.001mA~15mA, DC: 0.001mA~7.5mA 3 in 1 functions, with AC, DC Hi-Pot test, Insulation test. Built in 100 sets memory Arcing detect function 8 ports scanning function Independent 8 channels real-time open check Real-time check function, to ensure your products tested, no more loss test.
-
Emprise Corporation
Emprise Corporation is an engineering consulting firm serving the automotive, aerospace, industrial and alternate power industries. Our expertise in each of the individual fields of technology, systems integration, construction management, and integrated test facility design and delivery sets Emprise apart from other single-source engineering firms.
-
Megger Group Ltd.
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.
-
Cipher -
Avionics Interface Technologies
Supports Multiple Network Protocols including Ethernet, FibreChannel, & MIL-Firewire (AS5643) - High Performance Filtering & Search - Built-in protocol decoders for: FC-AE-ASM, FC-AE-RDMA, FCAE-1553, AS5643, Ethernet, IPv4, IPv6, UDP - User defined “protocol decoders” for custom & proprietary protocols - Database architecture for handling very large data sets - Multiple, Simultaneous views of data sets with time correlation of data across multiple views. - Compatible with common network analysis tools such as - Wireshark (e.g. Imports/Exports to PCAPNG) - Compatible with AIT’s Fibre Channel Test - Instruments for live capture, triggering, and filtering.
-
ISIO 200 -
OMICRON electronics
ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850 interface. For communicating with CMC test sets and real-time message exchange with peer devices, the fast GOOSE messaging is used. By using Client/Server communication, ISIO 200 can be integrated into Substation Automation Systems (SAS) and communicate to a station controller.
-
Shanghai Launch Electric Co., Ltd.
The cascaded DC high voltage generator is mainly used to detect the characteristic of all kinds of insulation materials under high voltage, the characteristic of the DC discharge of large gap, and the insulation chearacteristic of test samples iwth large capacitance like power cable, power capacitor, generator sets, etc.
-
FixGenius -
Ucamco N.V.
Tests show that FixGenius’ rule-based probe-mapping algorithms reduce pin deflection by up to 25% compared with traditional fixturing packages. FixGenius comes with a powerful Fixture Editor that allows the user to change the probe mapping. If a solution is mathematically possible, FixGenius’ algorithms will find it, and pick the one with least deflection. If the job simply cannot be done with one single fixture, FixGenius will fully automatically split the test into multiple fixtures or into fixture and flying probe test sets, with guaranteed test integrity.
-
GIT GIS -
HV Hipot Electric Co.,Ltd.
GIT GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer,high voltage coupling capacitors and all components in a sealed space.High voltage generated with two modes:using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object.The other one is to obtain required high voltage directly from high voltage transformer.
-
Keystone Compliance
Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to water jets and powerful water jets. These tests are numbered IPX5 and IPX6. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of water jets, would always be a 5, and in the case of powerful water jets, would always be a 6.
-
Keystone Compliance
Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to spraying water and splashing water. These tests are numbered IPX3 and IPX4. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of spraying water, would always be a 3, and in the case of splashing water, would always be a 4.