Showing results: 4396 - 4410 of 5224 items found.
-
T&C Power Conversion
100 W to 2400 W 13.56 MHz Analog/Digital, RS-232, USB interfaces Low Harmonic Distortion Automatic and Manual Gain Control High Speed Pulsing (Bursting) controls Compatible with T&C''''s Matching Networks GUI Software (complete PC control) Includes all essential RF power/communication cables and mounting brackets Air cooled (Air & Water 1200 W +) Half rack mount or stand alone versions Ideal for: Industrial, Scientific, and Medical Applications
-
Integris 3000 -
Absolute Analysis
Most modern cell tower network configurations place the Remote Radio Head (RRH) at the top of the tower and the baseband unit(BBU) at the bottom of the tower. While this configuration is advantageous for both computational efficiency and mitigation of RF loss across the cable, it means the only place along RF can be accessed is at the top of the tower. This forces field technicians to have to climb the tower to measure and debug RF noise problems.
-
Pulse Electronics
Pulse continues to lead the way with a broad range of components that enable twisted-pair copper high-speed services to homes and businesses. Pulse components are also used in cable modems and the consumer electronics that provide home networking services. Our high-performance transformers support home phone line and power line networks. These transformers are designed to exceed ANSI and ETSI standards, and have excellent THD performance and small footprints.
-
Virginia Panel Corporation
For maximum versatility and easy access to instrument-side wiring and cable assemblies, VPC offers a selection of slide kits designed to fit most common test racks. Slides are rated to support 180 lbs (81 kg) to accommodate even the largest fixtures. Measure the rack depth between mounting rails and choose the slide kit that fits the rack. A rack extender kit is available for mounting to racks with recessed rails.
-
897 -
Simpson Electric Company
Designed for conducting personal noise surveys, the 897 Dosimeter is versatile enough for the experienced hygienist but simple enough for the novice technician. The data storage feature allows you to view reports on the computer or print them for use later during inspections. Purchase the 897 by itself or in the SMS-2 kit with all of the relevant accessories, including calibrator, nose cone, microphone clip, wind screen, and serial and parallel printer cables.
-
MT310-104 -
ALTINEX, Inc.
The MT310-104 is a Balanced Stereo Audio Matrix Switching Card. This card allows any input to be independently switched to any of the outputs. Also, any input may simultaneously drive multiple outputs. All inputs and outputs can be wired for unbalanced stereo audio, or balanced audio allowing longer cable runs and superior noise resistance. Click the image below for your own copy of the MultiTasker Design Guide as a PDF.
-
SUBT-3.0 -
Dynamic Load Monitoring Ltd.
The Subsea Tensile Link is specially designed for working in subsea conditions and is used for measuring tensile loads. With an optional integral 4-20mA amplifier the load cell is packaged in a wooden case with a subsea rated signal cable to customer specific lengths or alternatively can be supplied with a TW-3.0-S display. Fully sealed with a subsea connector and pressure tested to over 250Bar the load cell is the ideal instrument for easily and accurately measuring subsea loads.
-
In-Phase Technologies, Inc.
Over the years, In-Phase Technologies has received many requests for frequency conversion units. Our standard product line of frequency converters includes models that operate from RF though 60 GHz. Many options are available to complement our standard offerings. We also have a series of RF-to-optical converters that allows customers to send RF and microwave signals over fiber optic cables.
-
Acroname, Inc
Get everything you need to evaluate MTM and develop your next functional test system with Acroname's MTM Evaluation Kit. The MTM Evaluation Kit includes: one MTM Development Board, one MTM USBStem Module, one MTM 1 Channel Power Module, one MTM IO Serial Module, one AC/DC 12V/5A power supply and one USB A to mini-B cable.
-
Pickering Interfaces Ltd.
Pickering's PXI Microwave Switch Modules vary from simple multiplexer and switch configurations to integrated matrices and large multiplexers. Most products are characterized for 50 operation however certain 75 versions are supplied either as standard or custom products. Remote versions occupy a single PXI slot with the microwave switches mounted separately from the host chassis, connection to the module is via a supplied control cable.
-
M774 -
ETC
The M774 is a dual channel USB oscilloscope compatible with USB 2.0 and USB 1.1 interface. The computer is isolated up to 500Vp from the measuring circuits of the oscilloscope. The ease of installation and connection to computer makes M774 extremely portable. The device is connected to computer using standard USB 2.0 cable and is powered directly from computer. The maximum power consumption of 2.35W makes this instrument highly usable with battery-powered notebooks.
-
BE70A -
Samtec Inc.
The BE70A Series uses a single block design for ganged cabling and compression mount to the PCB, making it easier to install and eliminates soldering. The block consists of two rows, with up to 16 contacts, and is available for both microstrip and stripline transmission types. This proprietary cable design offers superior grounding (360-degree grounding with stripline) around a spring-loaded signal contact and provides a 1.85 mm connectors for RF device interfacing.
-
8500 -
Teledyne Marine Bolt
The principal feature of the revolutionary Annular Port Source design is the annulus within which the air chamber and shuttle valve are housed.The air chamber and shuttle valve, in turn, surround a hollow passage through which air supply hoses and electrical control cables are routed. Peak output is optimized by an increased surface area of the toroidal-shaped bubble compared to the spherically shaped bubble generated by a conventional 4-port air gun.
-
T1000-15 -
Tesuto Systems
T1000-15 breakout box with dual 15 pin D-Sub connectors for signal capture or monitoring. Dual connectors provide a total of 30 test points plus a ground jack. All test points use standard size 4mm banana jacks. Test points may be connected using shorting banana cable to allow signal continuity. Ideal for continuity measurements, isolation testing, and signal capture.
-
JW3324 -
Shanghai Joinwit optoelectronic Tech,co.,Ltd
JW3324 Intermittent break analyzer is used to monitor the intermittent disconnection of interconnection devices in dynamic environment such as vibration. It can detect the contact reliability under vibration and display the time and times of disconnection.Connectors and cables are widely used in aviation, aerospace systems and military equipment. Therefore, JW3324 Intermittent break analyzer is a basic testing instrument used by manufacturers, research institutions and operators for manufacture-testing, research -developing, engineering construction and maintenance.