Filter Results By:

Products

Applications

Manufacturers

Showing results: 226 - 240 of 351 items found.

  • MANIFULATOR

    ECOPIA

    As one of the most important module in Probe_Station, manipulator is an accurate system that probe micro distance() and contact on the electrode of semiconductor wafer, device. ECOPIA's Manipulator is very easy to use and probe arm's elastic plate is good to protect sample's surface, from being damaged by Z direction movement.

  • Dielectric Test Fixture

    16451B - Keysight Technologies

    The 16451B is used to evaluate the dielectric constant of solid dielectric materials accurately, and complies with ASTM D150. The 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture.

  • pH 550 Benchtop pH Meter Kit with Probe, Stand, and pH Buffers

    OAKTON Instruments

    The PH 550 benchtop pH meter features a microprocessor chip which provides automatic temperature compensation, data storage, parameter setup, and Max/Min reading display. The meter offers a pH range from 0 to 14 and a three-point automatic calibration, with the ability to recognize standard buffer solutions (USA or NIST series). The advanced digital processing technology improves meter response time and measuring accuracy. A stable reading display icon appears when the measuring value is stable. The 3-in-1 combination pH electrode measures pH and temperature simultaneously. The compact meter includes a detachable electrode holder and three bottles of pH buffer solution. It has a dustproof and spillproof rating of IP54. Connectors are protected by silicone seal caps.

  • Analog Tank Test Kit

    4108 - M. C. Miller Company

    The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.

  • Gamma Detectors

    Exosens Group

    In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production

  • PH Meters

    MRC ltd.

    * Three reading modes* Smart-Read function. More stable the reading with auto recognition end-point* Cont-Read function. It is clear to read the sample changing in measurement process* Timed-Read function. Auto timed to store the reading* Auto upgrade hardware* Power-off protection, protect your data* Remind the electrode performance and calibration.

  • DC Resistance or Conductance of Insulating Materials

    ASTM D257 - National Technical Systems

    These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.

  • Ocean and River Instruments

    RINKO W - JFE Advantech Co., Ltd.

    Rinko W is an autonomously deployable data logger for long-term DO measurements. In order to protect the sensing foil against accumulating bio-fouling, the instrument has a mechanical wiper to sweep the optical window. The optical sensor does not have a membrane neither electrolytes, thus, it need less maintenance than electrode or galvanic sensors.

  • Sulfur Analyzer

    ELAn-4a - MRC ltd.

    A super wide uniform temperature zone (90mm)ensures complete combustion of coal samples.Dilated and thickened platimum electrode plates with bigger interface, make the interation more accurate and complete. With CAN bus, several sulfur analyzers can be controlled by a single PC, balances could be connected and data could be transmitted by real-time network transmission.

  • L20 Meters

    Model L20 pH/ORP - Electro-Chemical Devices

    The Model L20 pH/ORP/Temperature meter is an AC line powered or battery powered precision instrument. The Model L20 features auto buffer recognition during calibration for both USA Standard and NIST pH buffers. The L20 has automatic temperature compensation and it monitors the electrode’s slope and offset reporting the electrodes efficiency assuring that the measurement is correct.

  • pH and Temperature Data Logger

    pHTemp2000 - MadgeTech, Inc

    The pHTemp2000 is a battery powered, stand alone pH and temperature data logger with an LCD. This all-in-one compact, portable, easy to use device will measure and record data up to 131,071 readings per channel. The pHTemp2000 will directly connect to many commonly used pH and ORP electrodes through a female BNC connector mounted on its side.

  • Potentiostat/Galvinostat Electrochemical Instuments

    NuVant Systems, Inc.

    - 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information

  • Panel-mount Type pH Meter (Four-Wire Transmission, 4 point ararm, Time sharing Proportional Control)

    HP-960FTP - HORIBA, Ltd.

    HP-960FTP industrial pH meter is a high-end pH meter with a four-point alarm and a time sharing proportional control function.It connects pH sensor and measures pH and temperature in the sample water.It can also be linked with a cleaning device via an external input, extending its automatic operation time.Many types of electrodes are available to match the sample properties.

  • Electrochemical Analyzer

    EC Epsilon EClipse - inotiv

    The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.

  • Temperature Rise Tester

    WS-1 - Lisun Electronics Inc.

    Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right. It is designed and manufactured according to IEC884-1, GB2099.1-2008 and other relevant standard of electrical accessories.

Get Help