  • Automatic Potentiometric Titrator

    SKZ1043 - SKZ Industrial Co., Ltd

    Used for the detection of index with potential capacity analysis, can be used as special instrument for the detection of penicillin, by measuring the change in electrode potential, to measure the ion concentration, widely used for the pharmaceutical industry, food industry, petrochemical industry, metallurgy, environmental protection, electroplating materials industry.

  • Biosensor isoPod with USB

    EPU352 - eDAQ Pty Ltd.

    A compact signal conditioner for monitoring low current, two-electrode (anode and cathode) amperometric sensors. By setting the polarization voltage to zero it can also be used as a zero resistance ammeter (ZRA).Electrical isolation ensures that readings are not influenced by nearby current sources such as conductivity, or voltammetric electrodes.

  • Universal Converter

    C8000 - optek

    Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.

  • ExStik® 3-in-1 Chlorine, pH, Temperature Kit

    Extech EX800 - Extech Instruments Corporation

    The Extech EX800 ExStik 3-In-1 Kit includes the CL200 meter and pH electrode, reagent tablets (50 tests), four plastic cups, a weighted stand, pH buffer pouches, four CR2032 batteries, 48 inch neck strap, carrying case, and user manual. The meter measures Total Chlorine, pH, and Temperature with interchangeable flat surface electrodes that are included. Flat surface electrodes work in liquids, semi-solids and solids. Built-in memory can store/recall up to 15 readings and save the last calibrated value. It has a large 3-1/2 digit (2000 count) digital display with a bargraph and an automatic electronic self-calibration function for Chlorine (1, 2, or 3 point buffer calibration for pH).

  • Plasma CVD & Etching Systems

    MODEL DRIE-1000 - TEK-VAC INDUSTRIES Inc.

    A High Quality Plasma Deposition & Etch System, Ideal for R&D and Small Scale Production. Modified designs with capabilities of 12" wafers. Substrate heating to 500 C. Top loading / Optional loadlock. Multifunctional plasma network. Diversified pumping configurations. Variable electrode spacing. Customized features and components for specific applications.

  • Liquid Test Fixture

    16452A - Keysight Technologies

    The 16452A provides accurate dielectric constant and impedance measurements of liquid materials. The 16452A employs the parallel plate method, which sandwiches the liquid material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixure.

  • pHTestr® 50 Waterproof Pocket pH Tester,

    Premium 50 Series - OAKTON Instruments

    The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.

  • pHTestr® 50 Waterproof Pocket pH Tester,

    OAKTON Instruments

    The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.

  • Concentric Ring Set

    PRF-911 - Prostat Corporation

    - Measures surface resistance per ANSI/ESD STM11.11- Measures volume resistance per ANSI/ESD STM11.12- Meets the requirements of IEC 61340-2-3- Approximates surface & volume resistivity per ASTM D-257- Incorporates a spring loaded, self-aligning center electrode feature to reduce calibration frequency- Includes an insulated and metal dual test bed- Designed to work with a wide range resistance meter and one 5 lb. electrode- Certificate of calibration traceable to NIST included

  • 3D inversion geophysical software for Resistivity and Induced Polarization Data

    RES3DINV - Landviser, LLC

    This program is designed to invert data collected with a rectangular grid of electrodes. The arrays supported include the pole-pole, pole-dipole, inline dipole-dipole, equatorial dipole-dipole and Wenner-Schlumberger. The RES3DINV program uses the smoothness-constrained least-squares inversion technique to produce a 3D model of the subsurface from the apparent resistivity data alone.

  • PH350 Waterproof Single-Channel pH and ORP Smart Handheld Meter Kit

    OAKTON Instruments

    Get easy-to-read and accurate readings with auto-hold, auto-stable, and real-time measurements with stability indicators. The Environmental Express® Oakton® 300 series multiparameter meters utilize smart sensor technology with sensor heads that feature a built-in digital circuit for automatic sensor recognition. Sensor information including sensor ID, calibration data, and measurement setup is stored in sensor head and viewable on the meter display when sensor is connected. Sensor heads are easy to connect and disconnect with waterproof push-lock connector. Sensor cartridges (pH and EC) are replaceable for a cost-efficient and environmentally friendly system. Blue LED light on the sensor head functions as a reading stability indicator, flashing until the reading is stable. Meter stores up to 10,000 data sets with date-and-time stamp for accurate and easy analysis. Quickly transfer data from meter to computer seamlessly via USB cable or wirelessly via Wi-Fi. Easily take measurements and conveniently store meter and electrodes with built-in foldable stand on the back of the meter. Three grooves on the meter serve as electrode holders, to hold up to three electrodes simultaneously.

  • Scanning Electro-chemical Microscope

    920D - CH Instruments, Inc.

    The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.

  • Decay Accessory Set

    PGB-745 - Prostat Corporation

    - Designed for measuring charge movement and decay time of ESD controlled materials- The set consists of two stainless steel electrodes and two very high resistance test leads selected for this application- The high resistance leads minimize leakage during the test cycle and are equipped with male banana plugs

  • Compact Conductivity/TDS Meter

    Extech EC210 - Extech Instruments Corporation

    Compact handheld Conductivity Meter with long life carbon rod combination electrode measures Conductivity, TDS and Temperature. Units of measure include μS/cm, mS/cm, ppm, °F, and °C. The meter features three ranges for Conductivity and TDS plus adjustable Temperature compensation factor to maintain accuracy.

  • Electrocardiogram Logger Sensor

    NUL-218 - Neulog

    Identical in its use to a regular medical ECG (electrocardiogram), this is a rather simple three lead based logger sensor. It presents a heartbeat graph that allows a thorough examination of the heart's electrical activity from three different angles. Unlike most ECG devices, this unit operates with non-disposable electrodes.

Get Help