Showing results: 106 - 120 of 351 items found.
-
HIGHVOLT Prüftechnik Dresden GmbH
Electrostatic precipitators are used for clean process and exhaust gases, for example, in the cement and building materials industry, in steel mills, in conventional power plants, and in waste incineration plants. The dust particles are discharged electrostatically charged by a spray electrode, deflected by a DC electric field and deposited on the electrode.
-
16453A -
Keysight Technologies
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
-
LAQUA DO210 -
HORIBA, Ltd.
Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsAuto log data; built-in memory can store up to 500 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmCasing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty
-
CX-L19 -
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
Extech PH220-C -
Extech Instruments Corporation
The Extech PH220-C pH Meter is a Palm pH with Cabled Electrode. Microprocessor provides for Automatic Buffer recognition. Memory stores 25 readings. Large LCD displays pH or mV and temperature simultaneously. Includes cabled pH electrode, protective holster, pH buffers and 9V battery.
-
-
-
SEC Co., Ltd.
Inspects the quality of finished cells by measuring the gap between the battery electrode laminate and aluminum can.
-
16092A -
Keysight Technologies
Use this test fixture with parallel electrodes for impedance evaluation of both lead and SMD components.
-
NuVant Systems, Inc.
The operando cells, designed to interface with certain IR and Raman spectrometers, enable study of electrode surfaces during normal operation. Choose between the "fuel cell" and "solid electrode" configurations. These custom - designed tools can help your research lab understand how materials behave under operation.
-
EA164 -
eDAQ Pty Ltd.
The QuadStat is a software-controlled four-channel potentiostat. Each channel can be used as a single three-electrode potentiostat. Alternatively two (bipotentiostat), three, or four working electrodes can be used in a single reaction chamber with a common reference and auxiliary electrode. Potential at each working electrode can be independently adjusted between 2.5 V, or by using an external waveform generator to between 10 V. The QuadStat can measure currents from pico- to milliamperes, making it ideal for amperometric biosensor research including use as a multichannel monitor for in vivo nitric oxide or dissolved oxgen sensors.
-
OAKTON Instruments
Simply choose the electrode best suited for your application, connect the pHTestr BNC 10, calibrate, and measure. Change electrodes to suit your application without having to purchase another meter. Order electrodes separately. Large display and tactile keypad allow for easy calibration along with USA and NIST auto-buffer recognition. Hold function freezes reading on the display for easy recording. Additional features include Valox® sensor housing, self-diagnostic error messages, a battery-life indicator, and an auto-off function to maximize battery life.
-
16034H -
Keysight Technologies
The 16034H is designed for impedance evaluations of array-type SMD.The minimum SMD size that this fixture is adapted to evaluate is 1.6(L)x0.8(W)[mm]. Since the tip of the measurement electrodes are very thin and the device holder is extremely flat, the device can be shifted and the measurement electrodes can contact each of the elements of the array-type component.
-
CON 2700 -
Thermo Scientific
Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once.
-
PRF-912B -
Prostat Corporation
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included