Particle
fundamental objects of quanta.
See Also: Nanoparticle, Airborne Particle, Particle Accelerator, Particle Counters, Particle Detection, Wave
-
product
Image Analyzers
Morphologi Range
Morphological imaging is fast becoming an essential technology in the laboratory toolkit for particle characterization. The Morphologi 4 is a fully automated static image analysis system which provides a complete detailed description of the morphological properties of particulate materials. The Morphologi 4-ID combines the same automated static image analysis with Raman spectroscopy in a single, integrated platform, providing component-specific morphological descriptions of chemical species within a blend.
-
product
On-Site Oil Analyzer
MicroLab 40
MicroLab 40 is designed primarily for fleets operating equipment with hydraulic components or heavy equipment gears and transmissions. This would include off-road mining and construction vehicles as well as over-the-road equipment with hydraulics such as bucket trucks, fire engine ladder trucks or solid waste trucks. The MicroLab 40 is also used in applications for offshore drilling equipment. In addition to the basic oil chemistry and extended elemental analysis provided with the MicroLab 30, the MicroLab 40 model includes a particle counter which provides critical analysis for cleanliness of hydraulic oils and gear oils to determine the health of those oils and mechanical condition of those components.
-
product
Magnet Testing
magtrack
The magtrack makes it possible to detect the absolute 3D position in space as well as the orientation of a magnetically marked particle over a course of time. The magtrack system is modular and can therefore be adapted to any installation and system.
-
product
Raman Spectroscopy Analysis Laboratory
Rocky Mountain Laboratories, Inc.
Raman is used to analyze organic and inorganic materials. Bulk and small particle materials can be analyzed. Raman microscopy allows for the identification of particle as small as 1 µm.
-
product
SparkFun Photodetector Breakout
MAX30101 (Qwiic)
The SparkFun Photodetector Breakout is an updated version of the SparkFun Particle Sensor Breakout includes the MAX30101, a highly sensitive optical sensor and successor to the MAX30105 and MAX30102. The MAX30101 Breakout utilizes a photon detector to measure the amount of returning light that is reflected back from the LEDs. This is useful for various applications like particle (i.e. smoke) detection, proximity measurements, and even photoplethysmography. To make it even easier to use this breakout, all communication is enacted exclusively via I2C, utilizing our handy Qwiic system. However, we still have broken out 0.1" spaced pins in case you prefer to use a breadboard.
-
product
Magnetic Particle Flaw Detector
MT-1B
MT-1B magnetic particle flaw detector adapts high-capacity lithium battery pack, converse DC to AC through variable-frequency, providing magnetic powder flaw detector with magnetic power supply. With low power consumption, it can continuous work more than four hour after charging. It especially suits for working in the wild and aerial area.
-
product
Fourier Transform Infrared Spectroscopy (FTIR)
Rocky Mountain Laboratories, Inc.
FTIR Analysis is used to analyze organic materials. Bulk and small particle materials can be analyzed. FTIR microscopy analysis allows for the identification of particle as small as 10 µm.
-
product
Centrifugal FFF
CF2000
The new advanced Postnova CF2000 Series was developed to become the first professional modular Centrifugal FFF system available. It is completely controled by the NovaFFF single software platform which runs the entire system from autosampler to detectors. The CF2000 Centrifugal FFF incorporates the combined proven know-how and the technologies from three decades of leadership in FFF. Due to its unique design, the CF2000 Centrifugal FFF system offers more flexibility, higher robustness and better performance than traditional particle sizer systems. The CF2000 allows high resolution particle separation and sizing at the same time and consequently sets a complete new standard and offers a real alternative to traditional particle characterization techniques.
-
product
Alpha Spectroscopy
Alpha spectroscopy is used to identify and quantify radionuclides based on the alpha particles emitted in the decay process. Similar to Gamma Spectroscopy, energy spectra are generated with high precision detectors and electronics and analyzed with special software. Typically, samples are measured following chemical separation to isolate the radionuclides of concern due to the complexity associated with correcting for these interferences with spectrum analysis software as is common for many Gamma Spectroscopy measurements.
-
product
NPIRI Fineness of Grind Gauge
2070
The Elcometer 2070 NPIRI Fineness of Grind Gauge is used to determine particle size and the fineness of grind of particles in printing inks according to the National Printing Inks Research Institute (NPIRI) scale.
-
product
Dynamic Imaging Particle Analysis Technology
FlowCam® Macro
Yokogawa Fluid Imaging Technologies, Inc.
Based on proven FlowCam dynamic imaging particle analysis technology, and optimized for larger particles (50μm to 5mm), FlowCam Macro provides rapid particle characterization that goes beyond just particle size. Direct, image-based measurements of particle size and shape enable differentiation of particle types in a heterogeneous mixture.
-
product
PCIe Gen3 Full HD, High Speed, Compact Camera for Testing
CB019CG-LX-X8G3
Full HD, High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
product
Zeta Streaming Potential
ZETA-check
Particle interface potentials like the oscillating zeta streaming potential measured in the ZETA-check, represent the level of electrostatic repulsion between particles. The potential is generated by ionic end groups on particles and macro-molecules, respectively. With ZETA-check, the state of the actual charge of dispersions and macromolecular solutions is obtained within seconds. Solutions and dispersions from 0.3 nm up to 100 µm particle size qualify for measurement.
-
product
Preparative High Performance Liquid Chromatography System
ACCQPrep HP150
Compared to Flash chromatography, High-Performance Liquid Chromatography (HPLC) operates under a higher pressure and uses columns of a smaller particle size for higher efficiency and increased resolution for purer results.HPLC is divided into analytical and preparative forms. Prep HPLC uses larger particles, meaning less surface area for the stationary phase, a higher flow rate and, generally, less pressure than analytical HPLC. Flash and prep HPLC are both used to purify large sample quantities; in analytical HPLC, the goal is to achieve the highest resolution possible to observe each unique compound in the sample. Explore the ACCQPrep® HP150 from Teledyne LABS to discover why ISCO is known worldwide for Prep HPLC.
-
product
Aerosol Neutralizer
3054
Aerosol neutralization is an important component of aerosol science and engineering. Neutralizing aerosol particles can reduce electrostatic losses of particles within tubing or to other surfaces. Neutralization is also critical to gathering reliable particle size data when using a sizing instrument based on electrical mobility.
-
product
Ingress Protection
Ingress Protection testing evaluates the resistance to particle and liquid entry for an enclosed product. After testing has been performed, the product receives an IP rating, based on IEC 60529, according to the achieved resistance to solid particles and liquids.
-
product
Automatically Differentiate Cyanobacteria
FlowCam® Cyano
Yokogawa Fluid Imaging Technologies, Inc.
Based on proven FlowCam® technology, the new FlowCam Cyano automatically identifies cyanobacteria from other algae and particles in aquatic samples. Using a patent-pending combination of excitation wavelength, phycocyanin fluorescence measurement and image recognition software, the system automates what used to be done manually using microscopy. After differentiating the cyanobacteria form the other algae in the sample, VisualSpreadsheet and Advanced Classifier software can be used to further characterize the specific types of all algae found in the sample.
-
product
Software
ThreeParticle
Imagine 3D simulation would be easy to learn in a few days, entry barriers would be minimal, and applications almost limitless. This is already a reality with our revolutionary ThreeParticle ™ software . In a single simulation platform, the Discrete Element Method (DEM) can be used to simulate multi-physical systems with complex particle shapes, including multi-body dynamics (MBS), structural mechanics (FEM) and liquids (CFD) - without coupling to external packages. The simple and intuitive operation via a new user interface is the daily routine of simulation.
-
product
Particle Impact Noise Detector
BW-LPD-D4000
FREQUENCY: SINE WAVE 27Hz TO 265HzACCELERATION: 0 TO 20G PEAKSHAKER: 100 FORCE LBS 3/4" IN STROKE 75 IN PER/SEC VELOCITYAMPLIFIER: 250 WATTS MINIMUMD.U.T. WEIGHT: 300 GRAMS PRACTICAL LIMIT @ 20G
-
product
Laser Diffraction Systems
Since the release of the 7991 in 1974, the first commercially available particle size analyzer, Microtrac has been at the forefront of Laser Diffraction technology. By continuously improving the instrument technology, Microtrac offers customers a robust portfolio of Laser Diffraction instruments that’s ideal for particle sizing and characterization.
-
product
Shadow Sizing
The Shadow Sizer measures size, shape and velocity of particles using backlighting and image analysis software based on the shadowgraphy technique.The Shadow Sizer can measure a wide range of particles types including bubbles, liquid droplets, solid particles and any object with a well-defined contour.Data is analyzed by DynamicStudio and includes histograms of size distribution, 2.5D spatial distribution plots, cumulative histograms and tables.
-
product
Sample Pretreatment For Optical Emission Spectrometry
Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.
-
product
Frequency Conversion Rotating Magnetic Fla
MT-2XCF
MITECH MT-2XCF rechargeable frequency conversion rotating magnetic flaw detector is based on principle that the leakage magnetic field can absorb the magnetic powder. Make use of magnetic yoke magnetized the workpiece of ferromagnetic material. If there has defects it will produce leakage magnetic field that will adsorb magnetic powder. We could detect the flaw by observing the density of adsorption magnetic powder. It adopts large capacity lithium battery. By the inverter and the phase shifted signal processor to provide power for the detector, it solves the shortcomings of traditional magnetic particle detector relying on the 220V power supply. It has low power consumption and can continuous work for more than 6 hours. And the battery can be charged when the detector is on and off. Especially suitable for the field testing. It can choose the current frequency according to the flaw depth with unique frequency conversion communication design, that improve the detection sensitivity. It’s widely used in aircraft manufacturing, boiler and pressure vessels and other fields. It is a necessary professional precision instrument of quality control, in-service safety monitoring and life assessment.
-
product
Sand And Dust Test Chambers
Dongguan Amade Instruments Technology Co., Ltd
Sand and dust test chamber is also referred as dust-proof chamber, which is able to simulate the sand storm by putting the test piece in the chamber to judge the damage of sand-and-dust weather to products. Equipment is mainly applicable to determination of sealing performance of product shells based on the IPX5 and IPX6 degrees. Testing machine features a flow of air carrying dust in a vertical circulation, resulting in cycle use of sand during the test. Sand and dust testing has great significance to master the specimen’s performance to defend the penetration of dust particles, to withstand the abrasion of sands.
-
product
EDEM for Academia
Whether you want to deploy Discrete Element Method in your research or want to expand your curriculum with a DEM-related subject, EDEM software can add another dimension to your research and help expand horizons for your students. * Combine DEM simulation with experimental investigation to understand processes involving particles, * Develop new equipment and methods for bulk solids handling and processing, * Investigate fundamental characteristics of particle systems
-
product
Far Infrared Systems
Far-Infrared and terahertz (THz) radiation is the spectral region at the long wavelength end of the infrared and the short end of the microwave region, also known as the sub-millimeter wavelength spectral region. Recently, there has been an explosion of interest in THz applications as the radiation generated can penetrate various materials. THz light is commonly used in materials science, security, pharmaceutical com- pound analysis, biomedical imaging, superconducting materials, astronomy, and particle physics research.
-
product
PCIe Gen3 Full HD, High Speed, Compact Camera for
CB019MG-LX-X8G3
Full HD, High speed, compact, fast camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
product
Portable Particle Counter
3910 & 3905
Kanomax Portable Particle Counters – Models 3905 and 3910 are the smallest 6-channel portable particle counters in the industry. They measure particles at 1.0 CFM (28.3 LPM) and 1.77 CFM (50 LPM), respectively. Both models feature 0.3-micron minimum sensitivity, large color touch screens with a streamlined and user-friendly interface programmed with different standards to help guide users through the measuring and certification process.
-
product
PXIe-5764, 16-Bit, 1 GS/s, 4-Channel PXI FlexRIO Digitizer
785168-01
The PXIe-5764 is a PXI FlexRIO Digitizer that simultaneously samples four channels at 1 GS/s with 16 bits of resolution and features 400 MHz of analog input bandwidth. With up to 70 dB of SNR, the PXIe-5764 is ideal for applications that require a wide dynamic range with a wideband digitizer. The FlexRIO driver includes support for finite and continuous streaming modes, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA. Available in AC and DC coupled variants, the PXIe-5764 is ideal for both time and frequency domain applications, including radar prototyping, LIDAR, communications, microscopy, OCT, event detection, and particle physics.